CoChat

The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface

Jin, Jing, Li, Shurui, Daly, Ian, Miao, Yangyang, Liu, Chang, Wang, Xingyu, Cichocki, Andrzej · 2020 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 113

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

P300-based brain-computer interfaces (BCIs) provide an additional communication channel for individuals with communication disabilities. In general, P300-based BCIs need to be trained, offline, for a considerable period of time, which causes users to become fatigued. This reduces the efficiency and performance of the system. In order to shorten calibration time and improve system performance, we introduce the concept of a generic model set. We used ERP data from 116 participants to train the generic model set. The resulting set consists of ten models, which are trained by weighted linear discriminant analysis (WLDA). Twelve new participants were then invited to test the validity of the generic model set. The results demonstrated that all new participants matched the best generic model. The resulting mean classification accuracy equaled 80% after online training, an accuracy that was broadly equivalent to the typical training model method. Moreover, the calibration time was shortened by 70.7% of the calibration time of the typical model method. In other words, the best matching model method only took 81s to calibrate, while the typical model method took 276s. There were also significant differences in both accuracy and raw bit rate between the best and the worst matching model methods. We conclude that the strategy of combining the generic models with online training is easily accepted and achieves higher levels of user satisfaction (as measured by subjective reports). Thus, we provide a valuable new strategy for improving the performance of P300-based BCI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2019.2956488

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 113

Metadata

Authors
Jin, J., Li, S., Daly, I., Miao, Y., Liu, C., Wang, X., & Cichocki, A.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2020-01
Volume
28
Issue
1
Pages
3-12
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2991224771
Cited by
113
References
8
FWCI
10.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface. https://app.cochat.ai/papers/10.1109/tnsre.2019.2956488
The paper
Jin, J., Li, S., Daly, I., Miao, Y., Liu, C., Wang, X., & Cichocki, A. (2020). The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2956488

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.