The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
P300-based brain-computer interfaces (BCIs) provide an additional communication channel for individuals with communication disabilities. In general, P300-based BCIs need to be trained, offline, for a considerable period of time, which causes users to become fatigued. This reduces the efficiency and performance of the system. In order to shorten calibration time and improve system performance, we introduce the concept of a generic model set. We used ERP data from 116 participants to train the generic model set. The resulting set consists of ten models, which are trained by weighted linear discriminant analysis (WLDA). Twelve new participants were then invited to test the validity of the generic model set. The results demonstrated that all new participants matched the best generic model. The resulting mean classification accuracy equaled 80% after online training, an accuracy that was broadly equivalent to the typical training model method. Moreover, the calibration time was shortened by 70.7% of the calibration time of the typical model method. In other words, the best matching model method only took 81s to calibrate, while the typical model method took 276s. There were also significant differences in both accuracy and raw bit rate between the best and the worst matching model methods. We conclude that the strategy of combining the generic models with online training is easily accepted and achieves higher levels of user satisfaction (as measured by subjective reports). Thus, we provide a valuable new strategy for improving the performance of P300-based BCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Reference [7] has been widely investigated.”
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 1×
“Moreover, this classifier is simple to use and generally obtains better classification performance and acceptable accuracy [22], [40].”
MethodSmall sample size effects in statistical pattern recognition: Recommendations for practitioners
Raudys, S. J., & Jain, A. K. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75512 · Cited by 1,384
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 1×
“AS A field of technology, brain computer interfacing (BCI) provides a way to communicate between the brain and an external devices without the involvement of muscles and peripheral nerves [1]–[3].”
BackgroundA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 1×
“P300-based BCI systems have been widely investigated in over recent years and are beginning to be used in clinical applications [4], [5].”
BackgroundUnsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation
Lu, S., Guan, C., & Zhang, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015197 · Cited by 122 · cited 2×
“[17] proposed an online model adaptation technique without any calibration for a new user to achieve excellent performance.”
BackgroundWaytowich, N. R., Lawhern, V. J., Bohannon, A. W., Ball, K. R., & Lance, B. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00430 · Cited by 79 · cited 2×
“A better approach is to strategically update the model [10], [21], [47].”
Method
Cited by
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Transfer Learning for EEG-Based Brain–Computer Interfaces: A Review of Progress Made Since 2016
Wu, D., Xu, Y., & Lu, B.-L. (2022) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3007453 · Cited by 434
Review of Machine Learning Techniques for EEG Based Brain Computer Interface
Aggarwal, S., & Chugh, N. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09684-6 · Cited by 270
A systematic deep learning model selection for p300-based brain-computer interfaces
Abibullaev, B., & Zollanvari, A. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2021.3051136 · Cited by 53
P300 event-related potential detection using one-dimensional convolutional capsule networks
Liu, X., Xie, Q., Lv, J., Huang, H., & Wang, W. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.114701 · Cited by 23
Metadata
- Authors
- Jin, J., Li, S., Daly, I., Miao, Y., Liu, C., Wang, X., & Cichocki, A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2020-01
- Volume
- 28
- Issue
- 1
- Pages
- 3-12
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2991224771
- Cited by
- 113
- References
- 8
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface. https://app.cochat.ai/papers/10.1109/tnsre.2019.2956488
- The paper
- Jin, J., Li, S., Daly, I., Miao, Y., Liu, C., Wang, X., & Cichocki, A. (2020). The Study of Generic Model Set for Reducing Calibration Time in P300-Based Brain–Computer Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2956488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.