Structure from motion with wide circular field of view cameras
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a method for fully automatic and robust estimation of two-view geometry, autocalibration, and 3D metric reconstruction from point correspondences in images taken by cameras with wide circular field of view. We focus on cameras which have more than 180 degrees field of view and for which the standard perspective camera model is not sufficient, e.g., the cameras equipped with circular fish-eye lenses Nikon FC-E8 (183 degrees), Sigma 8mm-f4-EX (180 degrees), or with curved conical mirrors. We assume a circular field of view and axially symmetric image projection to autocalibrate the cameras. Many wide field of view cameras can still be modeled by the central projection followed by a nonlinear image mapping. Examples are the above-mentioned fish-eye lenses and properly assembled catadioptric cameras with conical mirrors. We show that epipolar geometry of these cameras can be estimated from a small number of correspondences by solving a polynomial eigenvalue problem. This allows the use of efficient RANSAC robust estimation to find the image projection model, the epipolar geometry, and the selection of true point correspondences from tentative correspondences contaminated by mismatches. Real catadioptric cameras are often slightly noncentral. We show that the proposed autocalibration with approximate central models is usually good enough to get correct point correspondences which can be used with accurate noncentral models in a bundle adjustment to obtain accurate 3D scene reconstruction. Noncentral camera models are dealt with and results are shown for catadioptric cameras with parabolic and spherical mirrors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple View Geometry in Computer Vision
Hartley, R., & Zisserman, A. (2004) · doi:10.1017/cbo9780511811685 · Cited by 21,070
Robust Wide Baseline Stereo from Maximally Stable Extremal Regions
Matas, J., Chum, O., Urban, M., & Pajdla, T. (2002) · Procedings of the British Machine Vision Conference 2002 · doi:10.5244/c.16.36 · Cited by 1,350
Self-citation
Cited by
Structure from motion photogrammetry in physical geography
Smith, M. W., Carrivick, J. L., & Quincey, D. J. (2016) · Progress in Physical Geography: Earth and Environment · doi:10.1177/0309133315615805 · Cited by 772
A survey of structure from motion.
Özyeşil, O., Voroninski, V., Basri, R., & Singer, A. (2017) · Acta Numerica · doi:10.1017/s096249291700006x · Cited by 489
Treibitz, T., Schechner, Y., Kunz, C., & Singh, H. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.105 · Cited by 219
“calibrating the system using an SVP model [25], yielding feffective from (11).”
BackgroundMethodCamera Models and Fundamental Concepts Used in Geometric Computer Vision
Sturm, P. (2010) · now publishers, Inc. eBooks · doi:10.1561/9781601984111 · Cited by 164
Critical Configurations for Radial Distortion Self-Calibration
Wu, C. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.11 · Cited by 59
Metadata
- Authors
- Micusik, B., & Pajdla, T.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 2006-07
- Volume
- 28
- Issue
- 7
- Pages
- 1135-1149
- ISSN
- 0162-8828 (ISSN-L)
- 2160-9292
- OpenAlex
- W2131412102
- Cited by
- 171
- References
- 2
- FWCI
- 20.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.