The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Revealing cascading failure vulnerability in power grids using risk-graph
Open accessAbstract
Security issues related to power grid networks have attracted the attention of researchers in many fields. Recently, a new network model that combines complex network theories with power flow models was proposed. This model, referred to as the extended model, is suitable for investigating vulnerabilities in power grid networks. In this paper, we study cascading failures of power grids under the extended model. Particularly, we discover that attack strategies that select target nodes (TNs) based on load and degree do not yield the strongest attacks. Instead, we propose a novel metric, called the risk graph, and develop novel attack strategies that are much stronger than the load-based and degree-based attack strategies. The proposed approaches and the comparison approaches are tested on IEEE 57 and 118 bus systems and Polish transmission system. The results demonstrate that the proposed approaches can reveal the power grid vulnerability in terms of causing cascading failures more effectively than the comparison approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gephi: An Open Source Software for Exploring and Manipulating Networks
Bastian, M., Heymann, S., & Jacomy, M. (2009) · Proceedings of the International AAAI Conference on Web and Social Media · doi:10.1609/icwsm.v3i1.13937 · Cited by 11,675
Cascade-based attacks on complex networks
Motter, A. E., & Lai, Y.-C. (2002) · Physical Review E · doi:10.1103/physreve.66.065102 · Cited by 1,929
Cited by
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Self-citationArtificial intelligence, cyber-threats and industry 4.0: challenges and opportunities
Bécue, A., Praça, I., & Gama, J. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-020-09942-2 · Cited by 368
The ai-based cyber threat landscape: A survey
Kaloudi, N., & Li, J. (2021) · ACM Computing Surveys · doi:10.1145/3372823 · Cited by 310
A Critical Review of Robustness in Power Grids Using Complex Networks Concepts
Cuadra, L., Salcedo-Sanz, S., Del Ser, J., Jiménez-Fernández, S., & Geem, Z. (2015) · Energies · doi:10.3390/en8099211 · Cited by 277
Preventing Cascading Failure Through Fuzzy Co-Operative Control Mechanism Using V2G
Adnan, M., Ali, M., Basalamah, A., & Tariq, M. (2019) · IEEE Access · doi:10.1109/access.2019.2944848 · Cited by 30
Metadata
- Authors
- Zhu, Y., Yan, J., Sun, Y., & He, H.
- Venue
- IEEE Transactions on Parallel and Distributed Systems
- Published
- 2014-12
- Volume
- 25
- Issue
- 12
- Pages
- 3274-3284
- ISSN
- 1045-9219 (ISSN-L)
- 1558-2183
- 2161-9883
- OpenAlex
- W2025580831
- Cited by
- 161
- References
- 3
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Revealing cascading failure vulnerability in power grids using risk-graph. https://app.cochat.ai/papers/10.1109/tpds.2013.2295814
- The paper
- Zhu, Y., Yan, J., Sun, Y., & He, H. (2014). Revealing cascading failure vulnerability in power grids using risk-graph. IEEE Transactions on Parallel and Distributed Systems. https://doi.org/10.1109/tpds.2013.2295814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.