This article explores the application of the zero trust (ZT) security model to industrial control systems (ICS) in the power systems industry. With increasing digitization of industrial processes, traditional cybersecurity measures are proving inadequate to protect critical infrastructure from evolving threats. The ZT approach, based on the principle of “never trust, always verify”, offers a robust framework for enhancing security by requiring strict authentication and authorization for all access to systems and data. In this article we provide an overview of cybersecurity concepts and highlight the unique challenges faced by ICS in the power systems sector. We then overview the key principles of ZT, discuss how these can be adapted to secure ICS environments, and showcase ZT's effectiveness in mitigating risks and protecting critical operations in the power grid. The article concludes with recommendations for operators, including comprehensive assessments, strong authentication, network segmentation, continuous monitoring, and employee training.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpec63981.2025.10906998

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 18 references

Research works printed but not linked: 10

  1. 2024, Cybersecurity Best Practices for Industrial Control Systems
  2. 2024, Dark Reading, “ICS/OT Security
  3. Stafford, 2020, Zero Trust Architecture, NIST special publication, 800, 207
  4. Garton, 2024, Purdue Model Framework for Indus-trial Control Systems & Cybersecurity Segmentation
  5. 2024, Zero Trust Architecture, 800
  6. 2024, Zero Trust Maturity Model
  7. Micro, 2024, How to Apply a Zero Trust Security Model to ICS
  8. 2024, What is Zero Trust?
  9. 2024, Zero Trust Security Explained: Principles of the Zero Trust Model
  10. Alipour, 2022, Enabling a zero trust ar-chitecture in a 5g-enabled smart grid

Cited by

See all 2

Metadata

Authors
Farraj, A.
Affiliations
Texas A&M University (US)
Corresponding author
Farraj, Abdallah
Venue
2025 IEEE Texas Power and Energy Conference (TPEC)
Publisher
IEEE
Published
2025-02-10
Pages
1-5
OpenAlex
W4408183034
Cited by
0
References
18
FWCI
0.00
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Texas Power and Energy Conference (TPEC) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
  • Physical Sciences › Computer Science › Computer Networks and Communications › Access Control and Trust
Keywords
zero-trust architecture, industrial control systems, power systems, critical infrastructure security, network partitioning, continuous monitoring, employee security training, power system protection, industrial cybersecurity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On Using Zero Trust to Securing Industrial Control Systems in the Power Systems Industry. https://app.cochat.ai/papers/10.1109/tpec63981.2025.10906998
The paper
Farraj, A. (2025). On Using Zero Trust to Securing Industrial Control Systems in the Power Systems Industry. 2025 IEEE Texas Power and Energy Conference (TPEC). https://doi.org/10.1109/tpec63981.2025.10906998

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.