Zero-Voltage-Switching Half-Bridge DC–DC Converter With Modified PWM Control Method
Open accessThe DOI matches its Crossref record.
Abstract
Asymmetric control scheme is an approach to achieve zero-voltage switching (ZVS) for half-bridge isolated dc-dc converters. However, it is not suited for wide range of input voltage due to the uneven voltage and current components stresses. This paper presents a novel "duty-cycle-shifted pulse-width modulated" (DCS PWM) control scheme for half-bridge isolated dc-dc converters to achieve ZVS operation for one of the two switches without causing the asymmetric penalties in the asymmetric control and without adding additional components. Based on the DCS PWM control scheme, an active-clamp branch comprising an auxiliary switch and a diode is added across the isolation transformer primary winding in the half-bridge converter to achieve ZVS for the other main switch by utilizing energy stored in the transformer leakage inductance. Moreover, the auxiliary switch also operates at ZVS and zero-current switching (ZCS) conditions. Furthermore, during the off-time period, the ringing resulted from the oscillation between the transformer leakage inductance and the junction capacitance of two switches is eliminated owing to the active-clamp branch and DCS PWM control scheme. Hence, switching losses and leakage-inductance-related losses are significantly reduced, which provides the converter with the potential to operate at higher efficiencies and higher switching frequencies. The principle of operation and key features of the proposed DCS PWM control scheme and two ZVS half-bridge topologies are illustrated and experimentally verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
“Detailed analysis of primary-assisted soft-switching converters can be found in [250]–[253], and further detailed analysis of secondaryside-assisted soft-switching converters can be found in [253]– [256].”
BackgroundModeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399
“circuit operation and dc analysis have been reported in [16], and detailed ZVS analysis can be found in [28].”
BackgroundSelf-citationAffam, A., Buswig, Y. M., Othman, A.-K. B. H., Julai, N. B., & Qays, O. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110186 · Cited by 192
Tri-Modal Half-Bridge Converter Topology for Three-Port Interface
Al-Atrash, H., Tian, F., & Batarseh, I. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889583 · Cited by 161
Self-citationDual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
“DT-ATAB operating under ZVS turn-on are shown [25]–[27].”
Metadata
- Authors
- Mao, H., Abu-Qahouq, J., Luo, S., & Batarseh, I.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2004-07
- Volume
- 19
- Issue
- 4
- Pages
- 947-958
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2139651122
- Cited by
- 114
- References
- 0
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Zero-Voltage-Switching Half-Bridge DC–DC Converter With Modified PWM Control Method. https://app.cochat.ai/papers/10.1109/tpel.2004.830052
- The paper
- Mao, H., Abu-Qahouq, J., Luo, S., & Batarseh, I. (2004). Zero-Voltage-Switching Half-Bridge DC–DC Converter With Modified PWM Control Method. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2004.830052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.