The DOI matches its Crossref record.
A grid-interfacing power quality compensator for three-phase three-wire microgrid applications
Abstract
This paper proposes a grid-interfacing power quality compensator for three-phase three-wire microgrid applications with consideration of both the power quality of the microgrid and the quality of currents flowing between the microgrid and utility system. It is proposed that two inverters connected in shunt and series are used for each distributed generation (DG) system in the microgrid. In each inverter, both positive- and negative-sequence components are controlled to compensate for the effects caused by the unbalanced utility grid voltages. Specifically, the shunt inverter is controlled to ensure balanced voltages within the microgrid and to regulate power dispatches among parallel-connected DG systems, while the series inverter balances the line currents by injecting appropriate voltage components. A current-limiting algorithm is also proposed and integrated within the inverter control schemes to protect the microgrid from large fault currents during utility voltage sags. The proposed compensator has been tested in simulations and experimentally using a laboratory hardware prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Self-citationProportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
Self-citationHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Guerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965
Self-citationA review on distributed energy resources and MicroGrid
Jiayi, H., Chuanwen, J., & Rong, X. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.06.004 · Cited by 882
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
A Review on Microgrids’ Challenges & Perspectives
Saeed, M. H., Fangzong, W., Kalwar, B. A., & Iqbal, S. (2021) · IEEE Access · doi:10.1109/access.2021.3135083 · Cited by 539
Basak, P., Chowdhury, S., Halder nee Dey, S., & Chowdhury, S. P. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.043 · Cited by 508
Savaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2181432 · Cited by 475
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
A survey on control issues in renewable energy integration and microgrid
Badal, F. R., Das, P., Sarker, S. K., & Das, S. K. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0122-8 · Cited by 357
Autonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid
Savaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185914 · Cited by 347
Tenti, P., Paredes, H. K. M., & Mattavelli, P. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2093153 · Cited by 262
Metadata
- Authors
- Li, Y. W., Vilathgamuwa, D. M., & Loh, P. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2006-07
- Volume
- 21
- Issue
- 4
- Pages
- 1021-1031
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2176250420
- Cited by
- 194
- References
- 0
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.