The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Adaptive Decentralized Droop Controller to Preserve Power Sharing Stability of Paralleled Inverters in Distributed Generation Microgrids
Abstract
This paper addresses the low-frequency relative stability problem in paralleled inverter-based distributed generation (DG) units in microgrids. In the sense of the small-signal dynamics of a microgrid, it can be shown that as the demanded power of each inverter changes, the low-frequency modes of the power sharing dynamics drift to new locations and the relative stability is remarkably affected, and eventually, instability can be yielded. To preserve the power sharing stability, an adaptive decentralized droop controller of paralleled inverter-based DG units is presented in this paper. The proposed power sharing strategy is based on the static droop characteristics combined with an adaptive transient droop function. Unlike conventional droop controllers, which yield 1-DOF tunable controller, the proposed droop controller yields 2-DOF tunable controller. Subsequently, the dynamic performance of the power sharing mechanism can be adjusted, without affecting the static droop gain, to damp the oscillatory modes of the power sharing controller. To account for the power modes immigration at different loading conditions, the transient droop gains are adaptively scheduled via small-signal analysis of the power sharing mechanism along the loading trajectory of each DG unit to yield the desired transient and steady-state response. The gain adaptation scheme utilizes the filtered active and reactive powers as indices; therefore, a stable and smooth power injection performance can be obtained at different loading conditions. The adaptive nature of the proposed controller ensures active damping of power oscillations at different operating conditions, and yields a stable and robust performance of the paralleled inverter system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Small-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
Autonomous Load Sharing of Voltage Source Converters
Sao, C. K., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.838638 · Cited by 286
Power Flow Control of a Single Distributed Generation Unit
Dai, M., Marwali, M. N., Jung, J., & Keyhani, A. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911815 · Cited by 136
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“common approach to the design of the control loops is the use of PI controllers, with additional feed-forward compensation to improve the performance of current regulators [54], [65], [66].”
BackgroundMethodInfluentialGuerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Metadata
- Authors
- Mohamed, Y., & El-Saadany, E. F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-11
- Volume
- 23
- Issue
- 6
- Pages
- 2806-2816
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2124332712
- Cited by
- 1,230
- References
- 11
- FWCI
- 58.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.