The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Three-Port Series-Resonant DC–DC Converter to Interface Renewable Energy Sources With Bidirectional Load and Energy Storage Ports
Abstract
In this paper, a three-port converter with three active full bridges, two series-resonant tanks, and a three-winding transformer is proposed. It uses a single power conversion stage with high-frequency link to control power flow between batteries, load, and a renewable source such as fuel cell. The converter has capabilities of bidirectional power flow in the battery and the load port. Use of series-resonance aids in high switching frequency operation with realizable component values when compared to existing three-port converter with only inductors. The converter has high efficiency due to soft-switching operation in all three bridges. Steady-state analysis of the converter is presented to determine the power flow equations, tank currents, and soft-switching region. Dynamic analysis is performed to design a closed-loop controller that will regulate the load-side port voltage and source-side port current. Design procedure for the three-port converter is explained and experimental results of a laboratory prototype are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized averaging method for power conversion circuits
Sanders, S. R., Noworolski, J. M., Liu, X. Z., & Verghese, G. C. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.76811 · Cited by 1,205
A multiple-input DC-DC converter topology
Dobbs, B. G., & Chapman, P. L. (2003) · IEEE Power Electronics Letters · doi:10.1109/lpel.2003.813481 · Cited by 511
Family of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488
Transformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Three-Port Bidirectional Converter for Hybrid Fuel Cell Systems
Duarte, J. L., Hendrix, M., & Simoes, M. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889928 · Cited by 441
Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Application of Z-Source Inverter for Traction Drive of Fuel Cell—Battery Hybrid Electric Vehicles
Peng, F. Z., Shen, M., & Holland, K. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897123 · Cited by 370
A ZVS Bi-Directional DC–DC Converter for Multiple Energy Storage Elements
Liu, D., & Li, H. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.882450 · Cited by 283
Tri-Modal Half-Bridge Converter Topology for Three-Port Interface
Al-Atrash, H., Tian, F., & Batarseh, I. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889583 · Cited by 161
A three-port bi-directional converter for hybrid fuel cell systems
Michon, M., Duarte, J. L., Hendrix, M., & Simoes, M. G. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1354836 · Cited by 160
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Nejabatkhah, F., Danyali, S., Hosseini, S. H., Sabahi, M., & Niapour, S. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172465 · Cited by 406
A High Step-Up Three-Port DC–DC Converter for Stand-Alone PV/Battery Power Systems
Chen, Y.-M., Huang, A. Q., & Yu, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242491 · Cited by 305
Zhang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134051 · Cited by 102
Metadata
- Authors
- Krishnaswami, H., & Mohan, N.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2009-10
- Volume
- 24
- Issue
- 10
- Pages
- 2289-2297
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2134535896
- Cited by
- 411
- References
- 12
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Port Series-Resonant DC–DC Converter to Interface Renewable Energy Sources With Bidirectional Load and Energy Storage Ports. https://app.cochat.ai/papers/10.1109/tpel.2009.2022756
- The paper
- Krishnaswami, H., & Mohan, N. (2009). Three-Port Series-Resonant DC–DC Converter to Interface Renewable Energy Sources With Bidirectional Load and Energy Storage Ports. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2009.2022756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.