An Adaptive Flux Observer With Online Estimation of DC-Link Voltage and Rotor Resistance For VSI-Based Induction Motors
The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
An adaptive observer is proposed for concurrent estimation of rotor fluxes, unknown dc-link voltage, and rotor resistance of induction motor with voltage source inverters. For the reported flux observers and parameter estimators, the implied assumption had been that the input voltages were measured by sensors, or presumed to be known, for example while plug-in converters were utilized. However, this assumption may not be valid due to bus voltage variations, such as for battery powered servo drives, or propulsion system in hybrid electric vehicles. A drift in input voltage measurement results in state and parameter estimation errors. The proposed observer is capable of concurrent flux and dc-link voltage observation with online tuning of rotor resistance, while the phase currents and rotor speed are measured. No terminal voltage measurement is needed for this adaptive observer. The stability of the proposed observer is proved based on a Lyapunov function. Besides, it is shown that injection of a diagnosis signal is necessary to force the estimated parameters converge to the right values regardless of their initial conditions. A complex programmable logic device is implemented for the experimental setup, which controls an intelligent power module including insulated gate bipolar transistors. Extensive simulation and experimental tests verify the asymptotic convergence of the proposed observer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the case of DC-link voltage sensor fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [277]
Citations
Cites
Ioannou, P., & Sun, J. (1995) · Medical Entomology and Zoology · doi:10.1109/acc.1984.4171550 · Cited by 5,663
Electric Motor Drivers: Modeling, Analysis, and Control
Krishnan, R. (2001) · Cited by 1,561
Nonlinear control design : geometric, adaptive and robust
Marino, R., & Tomei, P. (1995) · Prentice Hall International (UK) Ltd. eBooks · Cited by 985
DSP-based speed adaptive flux observer of induction motor
Kubota, H., Matsuse, K., & Nakano, T. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.216542 · Cited by 908 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodObservers for flux estimation in induction machines
Verghese, G. C., & Sanders, S. R. (1988) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.3067 · Cited by 493 · cited 1×
“Consequently, direct and quadrature axes fluxes should be estimated by appropriate observers or estimators Traditionally, voltage model observers, which are based on the integration of the voltage equation or using low pass filters are used to estimate the flux [7].”
Jansen, P. L., & Lorenz, R. D. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.273627 · Cited by 464
Active Flux Concept for Motion-Sensorless Unified AC Drives
Boldea, I., Paicu, M. C., & Andreescu, G.-D. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002394 · Cited by 433 · cited 1×
“[32] introduced active flux concept to turn salient pole to nonsalient pole machines, which facilitated utilization of state observers for motion sensorless control.”
BackgroundSpeed sensorless field-orientation control of the induction machine
Tajima, H., & Hori, Y. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195904 · Cited by 381
Holtz, J., & Quan, J. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.813726 · Cited by 313 · cited 2×
“[8] J. Holtz and J. Quan, “Drift- and parameter-compensated flux estimator for persistent zer-stator-frequency operation of sensorless-controlled induction motor,” IEEE Trans.”
BackgroundDirect Torque Control of Sensorless Induction Motor Drives: A Sliding-Mode Approach
Lascu, C., Boldea, I., & Blaabjerg, F. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.824441 · Cited by 295
High-performance induction motor control via input-output linearization
(1994) · IEEE Control Systems · doi:10.1109/37.295967 · Cited by 253 · cited 1×
“Nevertheless, many high-performance closed-loop control algorithms for induction motors such as field oriented control [1], direct torque control [2]–[4], input–output feedback linearization, and adaptive output feedback control [5], [6] need”
BackgroundHoltz, J., & Quan, J. (2003) · Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344) · doi:10.1109/ias.2002.1043761 · Cited by 243
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240
MRAS Observers for Sensorless Control of Doubly-Fed Induction Generators
Cardenas, R., Pena, R., Clare, J., Asher, G., & Proboste, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921189 · Cited by 224
Global adaptive output feedback control of induction motors with uncertain rotor resistance
Marino, R., Peresada, S., & Tomei, P. (1999) · IEEE Transactions on Automatic Control · doi:10.1109/9.763212 · Cited by 217
Regenerating-mode low-speed operation of sensorless induction motor drive with adaptive observer
Kubota, H., Sato, I., Tamura, Y., Matsuse, K., Ohta, H., & Hori, Y. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800575 · Cited by 213 · cited 1×
“They may also be classified based on some extra parameters that are estimated in addition to flux such as rotor position or speed [23]–[26], rotor resistance [14], stator resistance [27], or a combination of them [28].”
BackgroundHigh-Performance Torque and Flux Control for Multilevel Inverter Fed Induction Motors
Kouro, S., Bernal, R., Miranda, H., Silva, C. A., & Rodriguez, J. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909189 · Cited by 208 · cited 1×
“Nevertheless, many high-performance closed-loop control algorithms for induction motors such as field oriented control [1], direct torque control [2]–[4], input–output feedback linearization, and adaptive output feedback control [5], [6] need”
BackgroundLascu, C., & Andreescu, G. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.874275 · Cited by 160
Sliding-Mode Flux Observer With Online Rotor Parameter Estimation for Induction Motors
Proca, A. B., & Keyhani, A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.891786 · Cited by 150
Flux observer with online tuning of stator and rotor resistances for induction motors
Jeon, S. H., Oh, K. K., & Choi, J. Y. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.1005393 · Cited by 124 · cited 1×
“They may also be classified based on some extra parameters that are estimated in addition to flux such as rotor position or speed [23]–[26], rotor resistance [14], stator resistance [27], or a combination of them [28].”
BackgroundDC-Link Capacitance Estimation in AC/DC/AC PWM Converters Using Voltage Injection
Abo-Khalil, A. G., & Lee, D. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002181 · Cited by 119 · cited 1×
“In [35], dc-link capacitance for pulsewidth modulation (PWM) converters is estimated using voltage injection.”
MethodHabetler, T. G., Profumo, F., Griva, G., Pastorelli, M., & Bettini, A. (1998) · IEEE Transactions on Power Electronics · doi:10.1109/63.654966 · Cited by 114
A new current model flux observer for wide speed range sensorless control of an induction machine
Rehman, H., Derdiyok, A., Guven, M. K., & Xu, L. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805579 · Cited by 102 · cited 1×
“[10] proposed a current model flux observer based on sliding mode functions that was not sensitive to rotor time constant.”
BackgroundVáclavek, P., & Bláha, P. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.862305 · Cited by 83
Parameter Sensitivity Analysis of an ImprovedOpen-Loop Speed Estimate forInduction Motor Drives
Bolognani, S., Peretti, L., & Zigliotto, M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.925178 · Cited by 80
Speed Observer and Reduced Nonlinear Model for Sensorless Control of Induction Motors
Khalil, H. K., Strangas, E. G., & Jurkovic, S. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2008.2000977 · Cited by 78 · cited 1×
“[30] proposed a flux estimator with a high gain speed observer.”
BackgroundA MRAS-Based Adaptive Pseudoreduced-Order Flux Observer for Sensorless Induction Motor Drives
Kojabadi, H. M., Chang, L., & Doraiswami, R. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850969 · Cited by 65
Soto, G. G., Mendes, E., & Razek, A. (1999) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19990293 · Cited by 64 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodDerdiyok, A. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851594 · Cited by 63 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodHigh performance torque and flux control for multilevel inverter fed induction motors
Kouro, S., Bernal, R. V., Silva, C., Rodríguez, J., & Pontt, J. O. (2006) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2006.347906 · Cited by 62 · cited 1×
“Nevertheless, many high-performance closed-loop control algorithms for induction motors such as field oriented control [1], direct torque control [2]‐[ 4 ], input‐output feedback linearization, and adaptive output feedback control [5], [6] need”
BackgroundMethodological Insights for Online Estimation of Induction Motor Parameters
Laroche, É., Sedda, E., & Durieu, C. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2007.916317 · Cited by 57 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodA hybrid speed estimator of flux observer for induction motor drives
Ide, K., Ha, J.-I., & Sawamura, M. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.862306 · Cited by 39 · cited 1×
“They may also be classified based on some extra parameters that are estimated in addition to flux such as rotor position or speed [23]–[26], rotor resistance [14], stator resistance [27], or a combination of them [28].”
BackgroundAlonge, F., D’Ippolito, F., Giardina, G., & Scaffidi, T. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.905632 · Cited by 37 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodYu, X., Dunnigan, M. W., & Williams, B. W. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873230 · Cited by 20 · cited 1×
“In [34], a phase voltage estimator with dead band compensation is proposed, while the dc-link voltage is assumed to be known.”
BackgroundA High-Performance Strategy for Sensorless Induction Motor Drive Using Variable Link Voltage
Kwon, Y. A., & Kim, S. K. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.887178 · Cited by 20 · cited 1×
“A speed sensorless induction motor with variable link voltage is proposed in [36], however, the dc-link voltage is not estimated.”
BackgroundRobyns, B., Berthereau, F., Cossart, G., Chevalier, L., Labrique, F., & Buyse, H. A. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.892703 · Cited by 17 · cited 1×
“In [31], a Luenbergertype flux observer is proposed such that the observer gains are obtained to minimize its sensitivity to the parameter uncertainties.”
BackgroundSpeed Sensorless DTC of Induction Motor Based on an improved Adaptive Flux Observer
Belkacem, S., Naceri, F., Betta, A., & Laggoune, L. (2006) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2005.1600816 · Cited by 15 · cited 1×
“Nevertheless, many high-performance closed-loop control algorithms for induction motors such as field oriented control [1], direct torque control [2]–[4], input–output feedback linearization, and adaptive output feedback control [5], [6] need”
BackgroundGadoue, S. M., Giaouris, D., & Finch, J. W. (2006) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2006.347284 · Cited by 7
An adaptive rotor flux observer for direct field oriented induction motor drives
Damiano, A., Gatto, G., & Marongiu, I. (2000) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/(sici)1099-1115(200003/05)14:2/3<275::aid-acs576>3.0.co;2-e · Cited by 6 · cited 1×
“Nevertheless, many high-performance closed-loop control algorithms for induction motors such as field oriented control [1], direct torque control [2]–[4], input–output feedback linearization, and adaptive output feedback control [5], [6] need”
BackgroundZhang, Y., Wang, J., & He, C. (2008) · Cited by 3
Research works printed but not linked: 1
- 10.1109/TPEL.2002.805579 · DOI
Cited by
A review on fault detection and diagnosis techniques: basics and beyond
Abid, A., Khan, M. T., & Iqbal, J. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-020-09934-2 · Cited by 436
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
“A dc-link voltage estimator suitable for sensor fault detection in induction motor drives is presented in [14].”
BackgroundA comprehensive review on hybrid electric vehicles: architectures and components
Singh, K. V., Bansal, H. O., & Singh, D. (2019) · Journal of Modern Transportation · doi:10.1007/s40534-019-0184-3 · Cited by 357
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
BackgroundNajafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250
“In [18], an observer with estimation of dc-link voltage and rotor resistance is proposed, which can be used for voltage-fault detection and reconfiguration.”
MethodSelf-citation
Metadata
- Authors
- Salmasi, F. R., Najafabadi, T. A., & Maralani, P. J.
- Affiliations
- University of Tehran (IR)
- ORCID
- Salmasi, Farzad R
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-05
- Volume
- 25
- Issue
- 5
- Pages
- 1310-1319
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2148277074
- Cited by
- 77
- References
- 41
- Citations by year
- 2025: 6 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 9 · 2017: 4 · 2016: 2 · 2015: 6 · 2014: 7 · 2013: 9 · 2012: 5
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- adaptive flux observer, rotor resistance estimation, induction motor, voltage source inverter, sensorless control, Lyapunov stability, parameter convergence, hybrid electric vehicles, FPGA implementation, intelligent power module
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.