Abstract
An adaptive observer is proposed for concurrent estimation of rotor fluxes, unknown dc-link voltage, and rotor resistance of induction motor with voltage source inverters. For the reported flux observers and parameter estimators, the implied assumption had been that the input voltages were measured by sensors, or presumed to be known, for example while plug-in converters were utilized. However, this assumption may not be valid due to bus voltage variations, such as for battery powered servo drives, or propulsion system in hybrid electric vehicles. A drift in input voltage measurement results in state and parameter estimation errors. The proposed observer is capable of concurrent flux and dc-link voltage observation with online tuning of rotor resistance, while the phase currents and rotor speed are measured. No terminal voltage measurement is needed for this adaptive observer. The stability of the proposed observer is proved based on a Lyapunov function. Besides, it is shown that injection of a diagnosis signal is necessary to force the estimated parameters converge to the right values regardless of their initial conditions. A complex programmable logic device is implemented for the experimental setup, which controls an intelligent power module including insulated gate bipolar transistors. Extensive simulation and experimental tests verify the asymptotic convergence of the proposed observer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the case of DC-link voltage sensor fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [277]
Citations
Cites
Ioannou, P., & Sun, J. (1995) · Medical Entomology and Zoology · doi:10.1109/acc.1984.4171550 · Cited by 5,663
Electric Motor Drivers: Modeling, Analysis, and Control
Krishnan, R. (2001) · Cited by 1,561
Nonlinear control design : geometric, adaptive and robust
Marino, R., & Tomei, P. (1995) · Prentice Hall International (UK) Ltd. eBooks · Cited by 985
DSP-based speed adaptive flux observer of induction motor
Kubota, H., Matsuse, K., & Nakano, T. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.216542 · Cited by 908 · cited 1×
“Nevertheless, we may classify the studied flux observers based on the observation methodology, such as extended Kalman filter [11]–[13], sliding mode observers [14]–[16], adaptive or model reference observers [17]–[21], and reduced order observers [22].”
MethodObservers for flux estimation in induction machines
Verghese, G. C., & Sanders, S. R. (1988) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.3067 · Cited by 493 · cited 1×
“Consequently, direct and quadrature axes fluxes should be estimated by appropriate observers or estimators Traditionally, voltage model observers, which are based on the integration of the voltage equation or using low pass filters are used to estimate the flux [7].”
Jansen, P. L., & Lorenz, R. D. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.273627 · Cited by 464
Active Flux Concept for Motion-Sensorless Unified AC Drives
Boldea, I., Paicu, M. C., & Andreescu, G.-D. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002394 · Cited by 433 · cited 1×
“[32] introduced active flux concept to turn salient pole to nonsalient pole machines, which facilitated utilization of state observers for motion sensorless control.”
BackgroundSpeed sensorless field-orientation control of the induction machine
Tajima, H., & Hori, Y. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195904 · Cited by 381
Holtz, J., & Quan, J. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.813726 · Cited by 313 · cited 2×
“[8] J. Holtz and J. Quan, “Drift- and parameter-compensated flux estimator for persistent zer-stator-frequency operation of sensorless-controlled induction motor,” IEEE Trans.”
BackgroundDirect Torque Control of Sensorless Induction Motor Drives: A Sliding-Mode Approach
Lascu, C., Boldea, I., & Blaabjerg, F. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.824441 · Cited by 295
Research works printed but not linked: 1
- 10.1109/TPEL.2002.805579 · DOI
Cited by
A review on fault detection and diagnosis techniques: basics and beyond
Abid, A., Khan, M. T., & Iqbal, J. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-020-09934-2 · Cited by 436
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
“A dc-link voltage estimator suitable for sensor fault detection in induction motor drives is presented in [14].”
BackgroundA comprehensive review on hybrid electric vehicles: architectures and components
Singh, K. V., Bansal, H. O., & Singh, D. (2019) · Journal of Modern Transportation · doi:10.1007/s40534-019-0184-3 · Cited by 357
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
BackgroundNajafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250
“In [18], an observer with estimation of dc-link voltage and rotor resistance is proposed, which can be used for voltage-fault detection and reconfiguration.”
MethodSelf-citationUrresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2198077 · Cited by 164
Robust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140
“Furthermore, the works in [6], [12] considered only one sensor fault either in dc-link voltage or speed using respective observers to achieve FD.”
BackgroundGenduso, F., Cecati, C., Tommaso, A. O. D., Miceli, R., & Galluzzo, G. R. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2402645 · Cited by 114
Improved Sensorless Control of Permanent-Magnet Synchronous Machine Based on Third-Harmonic Back EMF
Liu, J. M., & Zhu, Z. Q. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2284299 · Cited by 98
Salmasi, F. R., & Najafabadi, T. A. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2159007 · Cited by 95
“A flux observer with online estimation of dc-link voltage and rotor resistance is given in [ 21 ].”
MethodSelf-citationZhang, X., Foo, G. H. B., Vilathgamuwa, D. M., Tseng, K. J., Bhangu, B. S., & Gajanayake, C. J. (2013) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0308 · Cited by 90
Efficiency Improvement in DTC of Six-Phase Induction Machine by Adaptive Gradient Descent of Flux
Taheri, A., Rahmati, A., & Kaboli, S. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2163420 · Cited by 81
“[31] presents an adaptive observer for estimation of rotor fluxes, dc-link voltage, and rotor resistance of IM.”
BackgroundA Comparison of Four Robust Control Schemes for Field-Weakening Operation of Induction Motors
Mengoni, M., Zarri, L., Tani, A., Serra, G., & Casadei, D. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2156810 · Cited by 81
Zhao, L., Huang, J., Chen, J., & Ye, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2504399 · Cited by 76
“[30] propose an identification algorithm for Rs,Rr and dc voltage on the basis of Lyapunov’s second law of stability.”
BackgroundOn-Line Identification of Winding Resistances and Load Torque in Induction Machines
Verrelli, C. M., Savoia, A., Mengoni, M., Marino, R., Tomei, P., & Zarri, L. (2014) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2013.2285604 · Cited by 68
Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives
Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2311126 · Cited by 65
Fang, J., & Ren, Y. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2161060 · Cited by 62
Smooth Fault-Tolerant Control of Induction Motor Drives With Sensor Failures
Liu, Y., Stettenbenz, M., & Bazzi, A. M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2848964 · Cited by 58
A Novel Direct Torque and Flux Control Method of Matrix Converter-Fed PMSM Drives
Xia, C., Zhao, J., Yan, Y., & Shi, T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293171 · Cited by 57
Yin, Z., Zhang, Y., Du, C., Liu, J., Sun, X., & Zhong, Y. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2524414 · Cited by 54
Adaptive System Identification and Severity Index-Based Fault Diagnosis in Motors
Abid, A., Khan, M. T., Lang, H., & de Silva, C. W. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2917749 · Cited by 52
“problem-specific and requires an accurate mathematical model of the process that is typically described in the form of nonlinear, coupled differential equations [16], [20].”
Indirect vector control with simplified rotor resistance adaptation for induction machines
Jingbo, K., Zhang, K., & Wang, Z. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0422 · Cited by 48
Reactive-Power-Based MRAS for Online Rotor Time Constant Estimation in Induction Motor Drives
Cao, P., Zhang, X., Yang, S., Xie, Z., & Zhang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2800010 · Cited by 45
“In [8] and [9], a full-order Luenberger observer and a sliding-mode observer were established for parameter identification, respectively.”
MethodDemir, R., & Barut, M. (2017) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331217734631 · Cited by 41
Holakooie, M. H., & Iwański, G. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3042305 · Cited by 31
“The rotor time constant and rotor resistance identification systems based on adaptive full-order observers have been presented in [12]–[15], where advancing the development of an accurate and stable estimator is the main goal.”
BackgroundZhou, Y. H., Soh, Y. C., & Shen, J. X. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2228140 · Cited by 28
Control schemes for field weakening of induction machines: A review
Zarri, L., Mengoni, M., Tani, A., Serra, G., Casadei, D., & Ojo, O. (2015) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2015.7194523 · Cited by 25
Echeikh, H., Trabelsi, R., Iqbal, A., & Mimouni, M. F. (2018) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2017.12.022 · Cited by 22
Diagnosis of incipient faults in PMSMs with coaxially insulated windings
Barater, D., Buticchi, G., Gerada, C., & Arellano-Padilla, J. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699567 · Cited by 20
“As a matter of fact, it very difficult to produce electric machine with sine-wave back EMF without the presence of harmonics different from the fundamental one [13][14].”
BackgroundHuynh, D. C., Dunnigan, M. W., & Finney, S. J. (2010) · IEEE International Conference on Power and Energy · doi:10.1109/pecon.2010.5697624 · Cited by 20
“There are several algorithms for on-line parameter estimation of the IM such as model reference adaptive system (MRAS) based algorithms [1]-[4], Kalman filters (KF) [5]-[10], recursive least-squares (RLS) algorithms [11]-[19], neural networks (NN) [20]- [21], adaptive observers [22]-[ 23 ] and other techniques such as…”
MethodA New Flux Observer for Induction Motors with On-Line Identification of Load Torque and Resistances
Marino, R., Tomei, P., & Verrelli, C. M. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.00479 · Cited by 19
Reddy, S. R. P., & Umanand, L. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2883265 · Cited by 17
Zhang, J., Zhang, X., Yu, Y. H., Wang, B., & Xu, D. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3310517 · Cited by 17
“The observer methods [13], [14], [15], such as the sliding-mode flux observer [13], the Luen-berger flux observer [14], and the adaptive flux observer [15], use the Lyapunov function to design the switching function or the adaptive laws for rotor parameter estimation.”
MethodHasanzadeh, A., Reed, D. M., & Hofmann, H. F. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2872921 · Cited by 17
“These signals are often added to the voltage commands [16], [20].”
BackgroundTeng, Q. (2022) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2022.00036 · Cited by 13
Liu, J. M., & Zhu, Z. Q. (2015) · IEEE International Symposium on Sensorless Control for Electrical Drives (SLED) · doi:10.1109/sled.2015.7339258 · Cited by 12
On-line Rotor Time Constant Estimation in IFOC Induction Motor Drives
Testa, A., Caro, S. D., Foti, S., Scimone, T., & Scelba, G. (2018) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445281 · Cited by 12
“State observers [15], Full-order Luenberger observers [16] and sliding mode observers were also proposed for rotor time constant estimation [17]-[18], as well as extended Kalman filters [19]-[21] and Model Reference Adapting Systems (MRAS) [22]-[27].”
MethodYan, J., Wu, X., Zhu, Z. Q., & Liu, C. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3397960 · Cited by 14
“However, the dc-link voltage sensor may be faulty due to high humidity, high temperature, electromagnetic interference, and mechanical vibration [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20] [24], [25], [26], [27], [28].”
BackgroundAnalysis and Optimization of Current Dynamic Control in Induction Motor Field-Weakening Region
Zhang, X., Wang, B., Yu, Y. H., Zhang, J., Dong, J., & Xu, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2968978 · Cited by 10
“Since this is the inherent problem in vector control and many research works are presented to deal with this problem [17], [22], [23], this letter will not focus on this problem.”
BackgroundHussain, H., Yang, J., & Yang, G. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3136285 · Cited by 10
Teng, Q., Tian, J., Duan, J., Cui, H., Zhu, J. G., & Guo, Y. G. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056033 · Cited by 9
“Concretely speaking, for [4], the input voltage provided for observer comes from the output of controller.”
BackgroundMethodSavoia, A., Verrelli, C. M., Mengoni, M., Zarri, L., Tani, A., & Casadei, D. (2012) · International Power Electronics and Motion Control Conference (IPEMC) · doi:10.1109/epepemc.2012.6397507 · Cited by 8
Wang, W., & Lu, Z. (2020) · Energies · doi:10.3390/en13020353 · Cited by 10
Improved sensorless control of permanent magnet synchronous machine based on third-harmonic back-EMF
Liu, J. M., & Zhu, Z. Q. (2013) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2013.6556283 · Cited by 8
Chen, L., Sun, X., Jiang, H., & Xu, X. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/386174 · Cited by 13
Sensorless control based on third harmonic back-EMF and PLL for permanent magnet synchronous machine
Liu, J. M., & Zhu, Z. Q. (2013) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2013.6713347 · Cited by 7
Uncertainty-Aware Fault Diagnosis of Rotating Compressors Using Dual-Graph Attention Networks
Lee, S., Kim, Y.-S., Choi, H.-J., & Ji, B. (2025) · Machines · doi:10.3390/machines13080673 · Cited by 6
Yan, J., Wu, X., Zhu, Z. Q., & Liu, C. (2022) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems56177.2022.9982982 · Cited by 5
“[9] used an adaptive observer to online observe the dc bus voltage to suppress the rotor resistance estimation errors for the voltage source inverter-based induction motor system.”
MethodReviewing Fault Diagnosis Methods in Electric Drives: Power Subsystem and Electrical Machine
Demidova, G., Chen, H., Li, Y., Lukichev, D. V., & Anuchin, A. (2023) · International Siberian workshops and tutorials on electron devices and materials · doi:10.1109/edm58354.2023.10225122 · Cited by 5
“Approaches proposed in [52, 53] are an adaptive online observer designed for induction and PMSM motor drive systems to estimate the unknown DC link voltage, rotor fluxes, and rotor resistance simultaneously.”
MethodInsights on Observability and Identifiability Properties of Induction Motors at Steady-State
Verrelli, C. M. (2013) · IFAC Proceedings Volumes · doi:10.3182/20130703-3-fr-4038.00056 · Cited by 5
Utrata, G., Rolek, J., & Kapłon, A. (2019) · Energies · doi:10.3390/en12142676 · Cited by 5
Speed and traction control in electric vehicles with induction motors
Marino, R., Scalzi, S., & Verrelli, C. M. (2012) · IEEE International Conference on Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles & International Transportation Electrification Conference (ESARS-ITEC) · doi:10.1109/esars.2012.6387423 · Cited by 5
Montero, E. R., Vogelsberger, M. A., & Wolbank, T. (2022) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc51159.2022.9962946 · Cited by 4
“This information is available without the need of any external injection, complex neural network or additional resourceintensive observers, in contrast to [7-15].”
BackgroundMethodJo, G.-J., & Choi, J.-W. (2018) · Journal of Power Electronics · Cited by 4
Mousavi, G., & Dashti (2014) · International Journal of Automotive Engineering · Cited by 3
Switching rule design for inverter-fed induction motors
Scharlau, C. C., Dezuo, T. J. M., Trofino, A., & Reginatto, R. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6760619 · Cited by 3
Yan, J., Wang, X., Deng, Z., & Qixing, L. (2014) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6941020 · Cited by 3
A Review on Parameter Estimation Techniques in Decoupling Control of Induction Motor Drive
Chandra, B. M., Prasantlr, B. V., & Manindher, K. G. (2018) · International Conference on Electrical Energy Systems (ICEES) · doi:10.1109/icees.2018.8443209 · Cited by 3
“In [24], three leunberger observers were proposed, one for determination of Tr and rotor flux and the second for determination of rotor flux and speed, and the third for rotor flux and load torque observation.”
BackgroundGain-scheduled Adaptive Observer for Induction Motors: An LMI Approach
(2014) · Acta Polytechnica Hungarica · doi:10.12700/aph.11.01.2014.01.4 · Cited by 3
“In the literature, several solutions based on the model of induction machines provide an estimate of the flux vector [6]-[8].”
BackgroundOptimization Methods in Fault Detection and Diagnosis
Kulkarni, A. J. (2025) · Springer eBooks · doi:10.1007/978-981-96-5257-0_6 · Cited by 4
Control of Three-Phase PMSM Drive With Minimum Sensor Usage
Ren, S., Song, H., Chen, R., Xiao, D., Wang, Z., & Wang, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3592220 · Cited by 1
“Salmasi et al. [26] applie a flux observer to estimate the dc-link voltage and utilizes adaptive laws to improve system stability.”
State Estimation of Interior Permanent Magnet Synchronous Motor Drives Using EKF
Mathianantham, L., Gomathi, V., Ramkumar, K., & Balasubramanian, G. (2015) · Advances in intelligent systems and computing · doi:10.1007/978-81-322-2671-0_68 · Cited by 1
Estymacja prędkości kątowej w złożonych układach napędowych - zagadnienia wybrane
Dybkowski, M. (2013) · Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu · Cited by 1
An overview of hybrid electric vehicles
Sekhar, C. C., Chandrakar, N., Prakash, J., & Sugali, H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-18999-9.00002-8 · Cited by 2
Marković, N. A., Živanić, J. M., Lazarević, Z., & Iričanin, B. (2018) · Serbian Journal of Electrical Engineering · doi:10.2298/sjee1803319m · Cited by 1
“In theory, asymmetrical feeding does not create uneven rotor heating because rotor phase in relation to stator constantly changes [22, 23].”
BackgroundYan, J., Wu, X., Zhu, Z. Q., & Liu, C. (2022) · International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART) · doi:10.1109/smart55236.2022.9990553 · Cited by 1
“In [11], an dc-link voltage estimation method based on online adaptive observer is proposed.”
MethodElectric Machines and Drives in HEVs
(2011) · doi:10.1002/9781119998914.ch10 · Cited by 1
Embedded controlled fault tolerant inverter with a leg swap module for induction motor drive
Nagarajan, S., & Reddy, S. R. (2012) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2012.6484372
“Farzad R. Salmasi et al (2010) proposed an adaptive flux observer for concurrent estimation of rotor fluxes, unknown dc-link voltage, and rotor resistance of induction motor with voltage source inverters is presented in this paper.”
BackgroundSixth-Harmonic Back-EMF Based Sensorless Control for Switched-Flux Permanent Magnet Machines
Lin, T. C., Liu, J. M., & Zhu, Z. Q. (2016) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2016.7791776
“Back-EMF based sensorless control techniques can be categorised as integration of back-EMF which is PM excitation flux-linkage [6]-[8], zero-crossings of fundamental back-EMF [2][9], and harmonic back-EMF i.”
BackgroundZhang, Y., & Mi, C. C. (2018) · doi:10.1002/9781118964897.ch9
Electric Machines and Drives in HEVs
Mi, C. C., & Masrur, M. A. (2017) · doi:10.1002/9781118970553.ch10
Sensorless Control of Synchronous Machines with DC-Link Voltage Immunity and Adaptation
Varatharajan, A., & Wang, Y. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080212
“An adaptive observer is used to estimate the DC-link voltage and the rotor resistance of an induction machine in [8].”
MethodWolf, F. (2023) · Springer eBooks · doi:10.1007/978-3-662-67156-6_2
2010 Index IEEE Transactions on Power Electronics Vol. 25
(2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3278818 · Cited by 1
Es-Semyhy, M., Ba-Razzouk, A., Elharoussi, M., & Hilali, A. (2025) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2025.101008
Electric Machines and Drives in HEVs
Mi, C., & Masrur, M. A. (2025) · doi:10.1002/9781394295159.ch10
Fu, R., Wang, B., Huang, X., Wang, Y., & Xu, D. (2025) · IEEE International Symposium on Sensorless Control for Electrical Drives (SLED) · doi:10.1109/sled63792.2025.11154795
“An adaptive observer was proposed in [4], enabling simultaneous estimation of rotor flux and DC-link voltage using only stator current and rotor speed measurements.”
Metadata
- Authors
- Salmasi, F. R., Najafabadi, T. A., & Maralani, P. J.
- Affiliations
- University of Tehran (IR)
- ORCID
- Salmasi, Farzad R
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-05
- Volume
- 25
- Issue
- 5
- Pages
- 1310-1319
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2148277074
- Cited by
- 77
- References
- 41
- Citations by year
- 2025: 6 · 2024: 2 · 2023: 3 · 2022: 6 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 9 · 2017: 4 · 2016: 2 · 2015: 6 · 2014: 7 · 2013: 9 · 2012: 5
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- adaptive flux observer, rotor resistance estimation, induction motor, voltage source inverter, sensorless control, Lyapunov stability, parameter convergence, hybrid electric vehicles, FPGA implementation, intelligent power module
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.