The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Active-Power Control of Individual Converter Cells for a Battery Energy Storage System Based on a Multilevel Cascade PWM Converter
Abstract
The battery energy storage system is an essential enabling device of the smart grid, because it helps grid connection of massive renewable energy resources. This paper has a brief discussion on a battery energy storage system based on a multilevel cascade pulsewidth-modulated (PWM) converter for its practical use. The active-power control of individual converter cells is presented to make it possible to charge and discharge the battery units at different power levels while producing a three-phase balanced line-to-line voltage. This results in the maximum utilization of battery energy even when the power-handling capabilities of the battery units differ. Experimental results obtained from a 200-V, 10-kW, 3.6-kWh battery energy storage system verify the effectiveness of the presented active-power control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Multilevel converters for large electric drives
Tolbert, L. M., Peng, F. Z., & Habetler, T. G. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.740843 · Cited by 1,408
A multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J. W., & VanCoevering, J. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.536875 · Cited by 858
A new approach to enhance power quality for medium voltage AC drives
Hammond, P. W. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567113 · Cited by 857
A multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J., & VanCoevering, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530626 · Cited by 847
Maharjan, L., Inoue, S., Akagi, H., & Asakura, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014868 · Cited by 590
Self-citationA Review of Cell Equalization Methods for Lithium Ion and Lithium Polymer Battery Systems
Moore, S. W., & Schneider, P. J. (2001) · SAE Technical Paper Series · doi:10.4271/2001-01-0959 · Cited by 392
A non conventional power converter for plasma stabilization
Marchesoni, M., Mazzucchelli, M., & Tenconi, S. (2003) · PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1988.18125 · Cited by 345
Maharjan, L., Inoue, S., & Akagi, H. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002180 · Cited by 310
Self-citationNew technology and possible advances in energy storage
Baker, J. (2008) · Energy Policy · doi:10.1016/j.enpol.2008.09.040 · Cited by 301
Operation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Dynamic equalization techniques for series battery stacks
Kutkut, N. H., & Divan, D. M. (2002) · Proceedings of Intelec'96 - International Telecommunications Energy Conference · doi:10.1109/intlec.1996.573384 · Cited by 183
10-MW GTO converter for battery peaking service
Walker, L. H. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.52675 · Cited by 172
A nonconventional power converter for plasma stabilization
Marchesoni, M., Mazzucchelli, M., & Tenconi, S. (1990) · IEEE Transactions on Power Electronics · doi:10.1109/63.53158 · Cited by 151
Static VAr compensator (STATCOM) based on single-phase chain circuit converters
Ainsworth, J. D., Davies, M., Fitz, P. J., Owen, K. E., & Trainer, D. R. (1998) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19982032 · Cited by 141
Control method for cascaded H-bridge multilevel inverter with faulty power cells
Wei, S., Wu, B., Fahai, L., & Sun, X. (2003) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2003.1179224 · Cited by 102
Design and commissioning of a 5 MVA, 2.5 MWh battery energy storage system
Miller, N. W., Zrebiec, R. S., Hunt, G. W., & Deimerico, R. W. (2002) · IEEE PES Transmission and Distribution Conference and Exhibition · doi:10.1109/tdc.1996.545957 · Cited by 62
Cited by
Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
Self-citationMultilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
Self-citationEnergy management and planning in smart cities
Calvillo, C. F., Sánchez-Miralles, A., & Villar, J. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.133 · Cited by 479
Analysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
A Review of Power Electronics for Grid Connection of Utility-Scale Battery Energy Storage Systems
Wang, G., Konstantinou, G., Townsend, C. D., Pou, J., Vazquez, S., Demetriades, G. D., & Agelidis, V. G. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2586941 · Cited by 362
Metadata
- Authors
- Maharjan, L., Yamagishi, T., & Akagi, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-03
- Volume
- 27
- Issue
- 3
- Pages
- 1099-1107
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2060177551
- Cited by
- 278
- References
- 17
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.