The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Control of Parallel-Connected Power Converters for Low-Voltage Microgrid—Part I: A Hybrid Control Architecture
Abstract
A key feature of microgrid concept is the ability to operate in islanding mode. Under such operating scenario, the distributed generators within microgrid should form a high-quality voltage supply for the load to sustain its normal operation. Power converters, the interface of renewable sources and energy storage systems, are important components of microgrids. The size and the number of the power converters required will depend on the fluctuating power flow within the microgrid. In this paper, we propose a hybrid control architecture to balance the power shared among the multiple interfacing inverters and optimize the system-operating efficiency. Simulation and real-time test results are provided to validate the proposed hybrid control scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“However, the conventional droop control method has several disadvantages [50], [78], [80], [81]: • Poor transient performance or instability issues due to the use of average values of active and reactive power over a cycle.”
BackgroundGuerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Metadata
- Authors
- Yu, X., Khambadkone, A. M., Wang, H., & Terence, S. T. S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 2962-2970
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2146251580
- Cited by
- 226
- References
- 1
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.