The DOI matches its Crossref record.
Easy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives
Abstract
This paper focuses on sensor fault detection and isolation (FDI) for electrical systems. A new, easy and fast FDI algorithm is proposed, keeping system performances unchanged under certain faulty sensor conditions when reconfigurations are available. The proposed FDI algorithm is derived from a parity space approach and is based on temporal redundancies. It is insensitive to parameter variations since no model knowledge is required. Also, it is available for a large class of electrical systems such as single- or three-phase power converters, dc or ac electrical drives, etc. Moreover, the residual threshold used for FDI is accurately defined and is suitable for the whole operating range. Simulations results are presented to illustrate the good functionality of theoretical developments. Numerous experimental results are also shown to validate the effectiveness of the proposed FDI algorithm and to highlight its advantages for the control of electrical systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 34
- 10.1109/APEX.2007.357576 · doi:10.1109/apex.2007.357576
- 10.1109/TPEL.2006.880262 · doi:10.1109/tpel.2006.880262
- 10.1109/TIE.2009.2035456 · doi:10.1109/tie.2009.2035456
- 10.1109/TPEL.2009.2026046 · doi:10.1109/tpel.2009.2026046
- 10.1109/TIE.2006.878308 · doi:10.1109/tie.2006.878308
- 10.1109/TIE.2009.2031193 · DOI
- 10.1109/TIE.2009.2013683 · DOI
- 10.1109/TPEL.2009.2038217 · DOI
- 10.1109/TPEL.2010.2052472 · DOI · Paper page
- 10.1109/TIE.2009.2036634 · DOI
- 10.1109/TPEL.2010.2047407 · DOI · Paper page
- 10.1109/TPEL.2010.2060361 · DOI
- 10.1109/TIE.2009.2033824 · doi:10.1109/tie.2009.2033824
- 10.1108/03321641011008019 · DOI
- mustapha, 2006, Current sensor failure in a DFIG Wind-Turbine: Effect analysis, detection and control reconfiguration, Int Rev Electr Eng, 1, 426
- 10.1016/j.conengprac.2005.05.002 · DOI · Paper page
- 10.1109/TIA.2009.2039982 · DOI
- 10.1109/IECON.2006.347390 · DOI
- 10.1109/TII.2009.2020566 · doi:10.1109/tii.2009.2020566
- 10.1109/TPWRD.2010.2041372 · doi:10.1109/tpwrd.2010.2041372
- 10.1109/TIE.2006.878304 · DOI
- 10.1109/TPEL.2008.924849 · doi:10.1109/tpel.2008.924849
- 10.1109/TII.2008.2008642 · DOI
- 10.1109/TIE.2009.2036026 · DOI · Paper page
- bendjedia, 2009, Proc Euro Conf Power Electronics Applications, 1
- 10.1109/TPEL.2009.2014650 · doi:10.1109/tpel.2009.2014650
- li, 2010, An adaptive fault-tolerant multi sensor navigation strategy for automated vehicles, IEEE Trans Veh Technol, 59, 2815, 10.1109/TVT.2010.2050014 · doi:10.1109/tvt.2010.2050014
- 10.1109/IECON.2007.4460357 · DOI
- 10.1109/TIE.2009.2017562 · DOI
- 10.1109/IEMDC.2005.195777 · doi:10.1109/iemdc.2005.195777
- 10.1109/EURCON.2007.4400529 · DOI
- 10.1109/TCST.2007.903109 · DOI
- blanke, 2003, Diagnosis and Fault-Tolerant Control, 10.1007/978-3-662-05344-7 · DOI · Paper page
- 10.1109/DEMPED.2009.5292752 · doi:10.1109/demped.2009.5292752
Cited by
Wu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [302] another FDD method for CSs using the parity space approach is introduced, however, the procedure of the design is mathematically complicated.”
MethodRecent advances in sensor fault diagnosis: a review
Li, D., Wang, Y., Wang, J., Wang, C., & Duan, Y. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.111990 · Cited by 323
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“In [43], the fault detection is achieved by using a parity space approach.”
MethodJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Wang, X., Wang, Z., Xu, Z., Cheng, M., Wang, W., & Hu, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2876400 · Cited by 263
Diagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2271992 · Cited by 115
Khojet El Khil, S., Jlassi, I., Estima, J. O., Mrabet‐Bellaaj, N., & Marques Cardoso, A. J. (2016) · Electronics Letters · doi:10.1049/el.2016.2198 · Cited by 58
Field programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
Berriri, H., Naouar, W., Bahri, I., Slama-Belkhodja, I., & Monmasson, E. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0053 · Cited by 44
Self-citationFault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Metadata
- Authors
- Berriri, H., Naouar, M. W., & Slama-Belkhodja, I.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 490-499
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2007831174
- Cited by
- 197
- References
- 0
- FWCI
- 17.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.