Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems

Freire, Nuno M. A., Estima, Jorge O., Cardoso, Antonio J. Marques · 2014 · IEEE Transactions on Industry Applications

Abstract

Fault diagnosis is a mandatory feature in fault-tolerant systems, since it provides the information necessary for the fault isolation and system reconfiguration. Recently, permanent-magnet synchronous generator (PMSG) drives have achieved prominence in wind energy conversion systems (WECSs), due to their reliability and availability. In this paper, a new approach is proposed for current sensor fault diagnosis in PMSG drives for WECSs. As opposed to the conventional state-observer-based methods for current sensor faults, which require a system model and the respective parameters, the proposed diagnostic method uses the measured phase currents only. Thus, its main merits are simplicity and reliability in the diagnosis, making it suitable for real-time implementation and to trigger remedial procedures. In addition, current sensor and open-circuit faults can be distinguished, and the affected phase is effectively identified in both cases. The proposed diagnostic technique is applied to the two power converters of a conventional back-to-back topology, and its performance is analyzed by means of several experimental results.

Overview

Integrity signals

Registry

Crossref · 10.1109/tia.2013.2271992

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Cited by

See all 117

Metadata

Authors
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M.
Affiliations
  • University of Coimbra (PT)
  • University of Beira Interior (PT)
Venue
IEEE Transactions on Industry Applications
Published
2014-03
Volume
50
Issue
2
Pages
1206-1214
ISSN
  • 0093-9994 (ISSN-L)
  • 1939-9367
OpenAlex
W2061487652
Cited by
115
References
20
Citations by year
2026: 3 · 2025: 7 · 2024: 13 · 2023: 10 · 2022: 5 · 2021: 10 · 2020: 7 · 2019: 7 · 2018: 10 · 2017: 14 · 2016: 14 · 2015: 8 · 2014: 7
FWCI
5.80
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industry Applications (publishedVersion)
Funders
Portuguese Foundation for Science and Technology (SFRH/BD/40286/2007, PTDC/EEA-EEL/114846/2009, SFRH/BD/70868/2010)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
Keywords
permanent magnet synchronous generator, wind energy conversion system, fault-tolerant systems, open-circuit fault, current sensor fault, phase current measurement, back-to-back converter, fault isolation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems. https://app.cochat.ai/papers/10.1109/tia.2013.2271992
The paper
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014). A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2013.2271992

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.