A ZVS Interleaved Boost AC/DC Converter Used in Plug-in Electric Vehicles
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a novel, yet simple zero-voltage switching (ZVS) interleaved boost power factor correction (PFC) ac/dc converter used to charge the traction battery of an electric vehicle from the utility mains. The proposed opology consists of a passive auxiliary circuit, placed between two phases of the interleaved front-end boost PFC converter, which provides enough current to charge and discharge the MOSFETs' output capacitors during turn-ON times. Therefore, the MOSFETs are turned ON at zero voltage. The proposed converter maintains ZVS for the universal input voltage (85 to 265 Vrms), which includes a very wide range of duty ratios (0.07-1). In addition, the control system optimizes the amount of reactive current required to guarantee ZVS during the line cycle for different load conditions. This optimization is crucial in this application since the converter may work at very light loads for a long period of time. Experimental results from a 3 kW ac/dc converter are presented in the paper to evaluate the performance of the proposed converter. The results show a considerable increase in efficiency and superior performance of the proposed converter compared to the conventional hard-switched interleaved boost PFC converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emadi, A., Lee, Y. J., & Rajashekara, K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922768 · Cited by 1,461 · cited 1×
“Such ac/dc converters, which are used to charge the high-energy battery, usually consist of two stages: front-end boost converter, which performs input PFC and ac/dc conversion, and full-bridge dc/dc converter for battery charging and galvanic isolation [3].”
BackgroundAdvanced Integrated Bidirectional AC/DC and DC/DC Converter for Plug-In Hybrid Electric Vehicles
Lee, Y.-J., Khaligh, A., & Emadi, A. (2009) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2009.2028070 · Cited by 476
Cited by
He, P., & Khaligh, A. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2016.2630927 · Cited by 501
Design and Analysis of a Full-Bridge LLC-Based PEV Charger Optimized for Wide Battery Voltage Range
Wang, H., Dusmez, S., & Khaligh, A. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2013.2288772 · Cited by 293
Analysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
Analysis and Design of a New AC–DC Single-Stage Full-Bridge PWM Converter With Two Controllers
Das, P., Pahlevaninezhad, M., & Moschopoulos, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227915 · Cited by 74
Self-citationTai, B., Gao, C., Liu, X., & Chen, Z. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2535463 · Cited by 46
Metadata
- Authors
- Pahlevaninezhad, M., Das, P., Drobnik, J., Jain, P. K., & Bakhshai, A.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-08
- Volume
- 27
- Issue
- 8
- Pages
- 3513-3529
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1981908971
- Cited by
- 169
- References
- 2
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.