The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Diagnosis of Interturn Faults in PMSMs Operating Under Nonstationary Conditions by Applying Order Tracking Filtering
Abstract
Interturn faults in permanent magnet synchronous machines may have very harmful effects if not early identified. This study deals with the detection of such faults when the machine operates under varying speed conditions. The performance of two methods is analyzed and compared, i.e., the analysis of the third harmonic of the stator currents and the first one of the zero-sequence voltage components. The Vold-Kalman filtering order tracking algorithm is introduced and applied to track the harmonics of interest when the machine operates under a wide speed range and different load levels. This study also presents two reliable fault indicators especially focused to detect stator winding interturn faults under nonstationary speed conditions. Experimental results endorse the methodology proposed, showing its potential to carry out a reliable fault diagnosis scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
Self-citationSalmasi, F. R., Najafabadi, T. A., & Maralani, P. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2038268 · Cited by 77
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48
Research works printed but not linked: 28
- 10.1109/TPEL.2010.2050496 · DOI · Paper page
- tuma, 2005, Setting the passband width in the Vold–Kalman order tracking filter, Proc 12th Int Cong Sound Vib, 1
- 10.1109/TIE.2008.2007527 · DOI · Paper page
- 10.1109/TMAG.2006.879077 · DOI · Paper page
- 10.1109/TIE.2010.2062480 · DOI · Paper page
- 10.1109/28.738983 · DOI
- urresty, 2011, Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage, Proc Eur Conf Power Electron Appl, 1
- 10.1109/TIE.2007.895076 · DOI · Paper page
- 10.1109/FSKD.2009.220 · doi:10.1109/fskd.2009.220
- 10.1109/TIM.2003.814670 · doi:10.1109/tim.2003.814670
- 10.1109/TPEL.2011.2129577 · DOI · Paper page
- riba, 2010, Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions, Electric Power Syst Res, 80, 1277, 10.1016/j.epsr.2010.04.010 · DOI
- 10.1109/TPEL.2010.2055890 · doi:10.1109/tpel.2010.2055890
- 10.1109/TEC.2009.2032626 · DOI
- 10.1109/TIA.2002.1003411 · DOI · Paper page
- 10.1109/TEC.2009.2032622 · DOI
- 10.1109/TIE.2008.926773 · DOI
- 10.1109/TPEL.2010.2059047 · DOI · Paper page
- 10.1109/TMAG.2010.2062529 · DOI
- 10.1109/TIA.2006.880838 · DOI
- 10.1109/TPEL.2010.2060361 · DOI
- 10.1109/ICQR2MSE.2011.5976657 · doi:10.1109/icqr2mse.2011.5976657
- 10.1109/ICASSP.2000.860254 · doi:10.1109/icassp.2000.860254
- vold, 2000, Display operating deflection shapes from nonstationary data, Sound Vib, 34, 4
- 10.1109/TIE.2010.2081955 · DOI
- brandt, 2005, Main principles and limitations of current order tracking methods, Sound Vib Mag, 39, 19
- boqiang, 2007, Weak-signal detection and the application in detection of electric motor faults, Proc Int Conf Electr Mach Syst, 1103
- 10.1109/TIA.2008.921431 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The interesting approach is presented in [63] where the novel VKF-OT algorithm is introduced and applied to track the 3th harmonic of stator phase current and first one of the ZSVC for on-line detection of this failure.”
MethodRare-earth-free propulsion motors for electric vehicles: A technology review
Riba, J.-R., López-Torres, C., Romeral, L., & Garcia, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.121 · Cited by 265
Self-citationSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Metadata
- Authors
- Urresty, J.-C., Riba, J.-R., & Romeral, L.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-01
- Volume
- 28
- Issue
- 1
- Pages
- 507-515
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2003460769
- Cited by
- 164
- References
- 3
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.