The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Unified Triple-Phase-Shift Control to Minimize Current Stress and Achieve Full Soft-Switching of Isolated Bidirectional DC–DC Converter
Abstract
This paper presents a comprehensive analysis of the current-stress optimization and soft-switching operation of the isolated bidirectional dual active bridge (DAB) dc-dc converter with the unified triple-phase-shift (UTPS) control. On this basis, the current-stress-optimized modulation scheme is proposed for DAB, which leads to the minimum current stress with the required transmission power and voltage conversion ratio in the whole load range. Moreover, the full soft-switching operation is achieved for the converter simultaneously. Distinct from the previous modulation schemes, the proposed optimized modulation scheme is deduced from a unified analysis of TPS where all effective switching modes are investigated. A novel algorithm based on the Karush-Kuhn-Tucker (KKT) conditions is originally proposed to derive closed-form solutions for the global optimal control parameters. This paper also presents a typical closed-loop control strategy for DAB with TPS control and detailed descriptions about the closed-loop operation. A laboratory prototype is applied, and the experimental results validate that the current-stress optimization and efficiency improvement are realized by applying the optimized modulation scheme. The experimental results also verify the effectiveness of the closed-loop control strategy for DAB with TPS control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567
Generalized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Oggier, G. G., Garcia, G. O., & Oliva, A. R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2072966 · Cited by 498
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Tong, A., Hang, L., Li, G., Jiang, X., & Gao, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692276 · Cited by 455
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
Metadata
- Authors
- Huang, J., Wang, Y., Li, Z., & Lei, W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-07
- Volume
- 63
- Issue
- 7
- Pages
- 4169-4179
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2321782165
- Cited by
- 501
- References
- 19
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unified Triple-Phase-Shift Control to Minimize Current Stress and Achieve Full Soft-Switching of Isolated Bidirectional DC–DC Converter. https://app.cochat.ai/papers/10.1109/tie.2016.2543182
- The paper
- Huang, J., Wang, Y., Li, Z., & Lei, W. (2016). Unified Triple-Phase-Shift Control to Minimize Current Stress and Achieve Full Soft-Switching of Isolated Bidirectional DC–DC Converter. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2016.2543182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.