Unified Active Filter and Energy Storage System for an MW Electric Vehicle Charging Station
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A network of fast-charging stations is of great importance for widespread adoption of electric vehicles (EV) if the so-called range anxiety issue is to be resolved. As with petrol stations, we expect that multiple chargers will be co-located to form charging stations. This layout allows for the fast-charging station to make use of a common rectifier stage and several dc/dc stages to charge multiple EVs. This paper builds on our previous work where we proposed a novel dc-side filter for the 12-pulse rectifier and investigated the power profile for a MW fast-charging station. In this paper, we propose a novel control approach for the filter, based on the virtual resistor injection, which results in further reduction in dc ripple, ac-side harmonics, and filter VA ratings. We also demonstrate that, with the proposed topology and control, the filter stage can be used as dc-side energy storage system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Du, Y., Zhou, X., Bai, S., Lukic, S., & Huang, A. (2010) · 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2010.5433359 · Cited by 314 · cited 1×
“A thorough tradeoff study for both isolated and nonisolated dc/dc topologies was presented in [14] and [15].”
BackgroundSelf-citation
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Self-citationChakraborty, S., Vu, H.-N., Hasan, M. M., Tran, D.-D., Baghdadi, M. E., & Hegazy, O. (2019) · Energies · doi:10.3390/en12081569 · Cited by 384
Khalid, M. R., Alam, M. S., Sarwar, A., & Jamil Asghar, M. S. (2019) · eTransportation · doi:10.1016/j.etran.2019.100006 · Cited by 369
Electric Vehicle Charging Station Using a Neutral Point Clamped Converter With Bipolar DC Bus
Rivera, S., Wu, B., Kouro, S., Yaramasu, V., & Wang, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348937 · Cited by 305
Metadata
- Authors
- Bai, S., & Lukic, S. M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-12
- Volume
- 28
- Issue
- 12
- Pages
- 5793-5803
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2089930129
- Cited by
- 156
- References
- 1
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unified Active Filter and Energy Storage System for an MW Electric Vehicle Charging Station. https://app.cochat.ai/papers/10.1109/tpel.2013.2245146
- The paper
- Bai, S., & Lukic, S. M. (2013). Unified Active Filter and Energy Storage System for an MW Electric Vehicle Charging Station. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2013.2245146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.