A Parallel Topology for Inductive Power Transfer Power Supplies
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
High-power inductive power transfer (IPT) systems operate at power levels of 100 kW or more. However, existing high-power IPT power supplies are typically designed for one power level and are expensive to make, due to the use of high-power electronic components. This paper presents a parallel IPT power supply topology that can achieve high output power levels in a cost effective manner. The parallel topology can minimize uneven power sharing due to component tolerance, and does not require any additional reactive components for parallelization. In addition, it can continue to operate when a faulty parallel unit is electronically shut down, dramatically improving the availability and reliability of the systems. Furthermore, flexible output power levels may be achieved by connecting identical modules in parallel. A 6 kW parallel power supply has been constructed by connecting three 2 kW power supplies in parallel. The maximum efficiency of the power supply and track is measured to be 94%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a Single-Sided Flux Magnetic Coupler for Electric Vehicle IPT Charging Systems
Budhia, M., Boys, J. T., Covic, G. A., & Huang, C.-Y. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2179274 · Cited by 1,273 · cited 5×
“21 For lumped systems, the circular [65], bipolar [22] and double D [64] pads are commonly used for higher coupling factor and larger power transfer.”
BackgroundMethodSelf-citationWang, C.-S., Covic, G. A., & Stielau, O. H. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822038 · Cited by 1,213 · cited 1×
“Firstly, its variable operating frequency leads to poor stability (bifurcation) [79] at overload conditions.”
BackgroundSelf-citationDesign and Optimization of Circular Magnetic Structures for Lumped Inductive Power Transfer Systems
Budhia, M., Covic, G. A., & Boys, J. T. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143730 · Cited by 1,039 · cited 3×
“21 For lumped systems, the circular [65], bipolar [22] and double D [64] pads are commonly used for higher coupling factor and larger power transfer.”
BackgroundSelf-citationNarrow-Width Inductive Power Transfer System for Online Electrical Vehicles
Huh, J., Lee, S. W., Lee, W. Y., Cho, G. H., & Rim, C. T. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160972 · Cited by 669
Stability and control of inductivelycoupled power transfer systems
Boys, J. T., Covic, G. A., & Green, A. W. (2000) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20000017 · Cited by 559 · cited 6×
“VOC stands for the induced open-circuit voltage of the secondary magnetic structure [38, 66], and is given by:”
BackgroundMethodSelf-citationA Three-Phase Inductive Power Transfer System for Roadway-Powered Vehicles
Covic, G. A., Boys, J. T., Kissin, M. L. G., & Lu, H. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904025 · Cited by 439 · cited 4×
“Another emerging IPT application is to provide wireless power to electric vehicles while they are in motion on a roadway [16, 18, 19, 26-28, 34, 54].”
BackgroundSelf-citationA Unity-Power-Factor IPT Pickup for High-Power Applications
Keeling, N. A., Covic, G. A., & Boys, J. T. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027255 · Cited by 371 · cited 1×
“The LCL tuning topology [97, 98], as shown in Figure 2-18, has an additional inductor L3 connected in series with the load resistor, and the value of L3 is designed to be the same as Lpickup.”
BackgroundSelf-citationZCS $LCC$-Compensated Resonant Inverter for Inductive-Power-Transfer Application
Pantic, Z., Bai, S., & Lukic, S. M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081954 · Cited by 305 · cited 1×
“Based on the various topologies described in the last section, several IPT power supply topologies have been developed [36, 38, 56, 68-77].”
Joun, G. B., & Cho, B. H. (1998) · IEEE Transactions on Power Electronics · doi:10.1109/63.728328 · Cited by 291
Analysis and Design of an LCL-T Resonant Converter as a Constant-Current Power Supply
Borage, M., Tiwari, S., & Kotaiah, S. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.858729 · Cited by 271 · cited 10×
“A different parallel LCL-T resonant system is described in [2].”
BackgroundMethodInfluentialDevelopment and evaluation of single sided flux couplers for contactless electric vehicle charging
Budhia, M., Covic, G. A., Boys, J. T., & Huang, C.-Y. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6063826 · Cited by 232 · cited 1×
“As IPT applications continue to expand, electrification of personal transportation systems such as electric vehicles is becoming more popular [17, 21-25, 34, 35, 46-53].”
BackgroundSelf-citationA Direct AC–AC Converter for Inductive Power-Transfer Systems
Li, H. L., Hu, A. P., & Covic, G. A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159397 · Cited by 188
Self-citationThe design of a contact-less energy transfer system for a people mover system
Covic, G. A., Elliott, G., Stielau, O. H., Green, R. M., & Boys, J. T. (2002) · PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409) · doi:10.1109/icpst.2000.900035 · Cited by 165 · cited 2×
“The series tuning capacitor is normally designed to tune out part of the track inductance, allowing for a larger track inductor to be driven by a given inverter output voltage [59, 67].”
BackgroundSelf-citationA Series-Tuned Inductive-Power-Transfer Pickup With a Controllable AC-Voltage Output
Wu, H. H., Covic, G. A., Boys, J. T., & Robertson, D. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052069 · Cited by 154 · cited 2×
“In addition to the requirement for higher power levels, emerging IPT applications [1, 3, 87] also require IPT systems with different power ratings.”
BackgroundSelf-citationZhang, Y., Yu, M., Liu, F., & Kang, Y. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2200108 · Cited by 127
Practical Design Considerations for Contactless Power Transfer Quadrature Pick-Ups
Raabe, S., & Covic, G. A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2165461 · Cited by 110 · cited 1×
“However, it should be noted that adding a pickup to an IPT system might reduce the operating efficiency of an IPT system by 4% (at rated power levels) and 8% (at light load powers) [3, 86, 87].”
BackgroundSelf-citationBudhia, M., Covic, G. A., & Boys, J. T. (2010) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2010.5728981 · Cited by 54 · cited 4×
“Another emerging IPT application is to provide wireless power to electric vehicles while they are in motion on a roadway [16, 18, 19, 26-28, 34, 54].”
BackgroundSelf-citationA practical multiphase IPT system for AGV and roadway applications
Kissin, M. L. G., Hao, H., & Covic, G. A. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5618146 · Cited by 53 · cited 5×
“Due to its inherent galvanic isolation, IPT technology has been used in factory automation, clean-rooms, lighting [1-4], instrumentation and electronic systems [5-11], biomedical implants [12-14] and transportation systems [15-36].”
BackgroundSelf-citation
Cited by
Wireless Power Transfer—An Overview
Zhang, Z., Pang, H., Georgiadis, A., & Cecati, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835378 · Cited by 1,723
Wireless Power Transfer for Vehicular Applications: Overview and Challenges
Patil, D., McDonough, M. K., Miller, J. M., Fahimi, B., & Balsara, P. T. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2780627 · Cited by 991
Inductive Wireless Power Transfer Charging for Electric Vehicles—A Review
Mahesh, A., Chokkalingam, B., & Mihet-Popa, L. (2021) · IEEE Access · doi:10.1109/access.2021.3116678 · Cited by 513
“In article [167] LCL-T topology to achieve maximum power transfer efficiency a parallel inverter.”
BackgroundReview of static and dynamic wireless electric vehicle charging system
Panchal, C., Stegen, S., & Lu, J. (2018) · Engineering Science and Technology, an International Journal · doi:10.1016/j.jestch.2018.06.015 · Cited by 414
Zaheer, A., Hao, H., Covic, G. A., & Kacprzak, D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329693 · Cited by 371
Self-citation
Metadata
- Authors
- Hao, H., Covic, G. A., & Boys, J. T.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-03
- Volume
- 29
- Issue
- 3
- Pages
- 1140-1151
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2142088919
- Cited by
- 190
- References
- 18
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.