Comparison of Current-Limiting Strategies During Fault Ride-Through of Inverters to Prevent Latch-Up and Wind-Up
Abstract
Transient stability of a power network requires that generators remain synchronized and return to normal power export once a fault is cleared. For inverter-interfaced generators, one must ensure that current and voltage limiters do not latch-up and that controller integrators do not wind-up. A comparison of current-limiting strategies during fault ride-through of inverters to prevent latch-up and wind-up is presented. A voltage-controlled inverter with an inner current controller is used in this paper. Instantaneous limiting (saturation) and latched limiting with a variety of reset strategies are tested to check for correct operation when a fault is applied and cleared. All the cases were tested on an experimental system using 10-kVA inverters and low-impedance three-phase faults. The experimental results showing the current and voltage waveforms of the inverter are presented to test whether each strategy correctly transitioned from current limiting to normal operation once the fault was cleared and to examine the extent to which controller wind-up was a problem. Conclusions are drawn as to which current-limiting strategies provide good performance in ride-through and recovery from faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Self-citationFlexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185016 · Cited by 339
Nikkhajoei, H., & Lasseter, R. H. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385805 · Cited by 297
Voltage Support Control Strategies for Static Synchronous Compensators Under Unbalanced Voltage Sags
Castilla, M., Miret, J., Camacho, A., Matas, J., & de Vicuña, L. G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2257141 · Cited by 152
Modelling and Analysis of Fault Behaviour of Inverter Microgrids to Aid Future Fault Detection
Brucoli, M., Green, T. C., & McDonald, J. D. F. (2007) · International Conference on System of Systems Engineering · doi:10.1109/sysose.2007.4304253 · Cited by 97
Self-citationControl of a Multiple Source Microgrid With Built-in Islanding Detection and Current Limiting
Bloemink, J. M., & Iravani, M. R. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2198497 · Cited by 70
Parametric eigenstructure assignment via output feedback based on singular value decompositions
Duan, G. (2003) · IEE Proceedings - Control Theory and Applications · doi:10.1049/ip-cta:20030142 · Cited by 67
Power Electronics Cooling Effectiveness Versus Thermal Inertia
Meysenc, L., Jylhakallio, M., & Barbosa, P. M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.846548 · Cited by 65
Virtual resistance principle for the overcurrent protection of PWM voltage source inverter
Salha, F., Colas, F., & Guillaud, X. (2010) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2010.5638965 · Cited by 52
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Sadeghkhani, I., Hamedani Golshan, M. E., Guerrero, J. M., & Mehrizi-Sani, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517201 · Cited by 255
Liu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
Metadata
- Authors
- Bottrell, N., & Green, T. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-07
- Volume
- 29
- Issue
- 7
- Pages
- 3786-3797
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2016073067
- Cited by
- 311
- References
- 10
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Current-Limiting Strategies During Fault Ride-Through of Inverters to Prevent Latch-Up and Wind-Up. https://app.cochat.ai/papers/10.1109/tpel.2013.2279162
- The paper
- Bottrell, N., & Green, T. C. (2014). Comparison of Current-Limiting Strategies During Fault Ride-Through of Inverters to Prevent Latch-Up and Wind-Up. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2013.2279162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.