System Integration and Hierarchical Power Management Strategy for a Solid-State Transformer Interfaced Microgrid System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper investigates, and for the first time presents, the system integration of a novel solid-state transformer (SST) interfaced microgrid system. Accordingly, a hierarchical power management strategy is proposed for this system to enable islanding mode operation, SST enabled operation, and the seamless transfer between two modes. The proposed power management strategy includes three control levels: primary control for the local controller; secondary control for the dc microgrid bus voltage recovery; and tertiary control to manage the battery state of charge. The proposed system architecture and control strategies are detailed in this paper and a lab test bed is constructed to verify the system performance. Finally, several typical case studies are carried out. The experimental results verify the proposed system and distributed power management strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 3×
“proposed the hierarchical control for the ac/dc microgrid system in [16], [17].”
BackgroundOptimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002
10 kV/120 A SiC DMOSFET half H-bridge power modules for 1 MVA solid state power substation
Grider, D., Das, M., Agarwal, A., Palmour, J., Leslie, S., Ostop, J., Raju, R., Schutten, M., & Hefner, A. (2011) · 2011 IEEE Electric Ship Technologies Symposium · doi:10.1109/ests.2011.5770855 · Cited by 115 · cited 1×
“Compared with the conventional transformer plus rectifier architecture, the SST-enabled dc microgrid not only behaves as an active grid interface requiring decreased weight and space [22], [23], but can also potentially supply reactive power, compensate harmonic currents, etc.”
Background
Cited by
Microgrid supervisory controllers and energy management systems: A literature review
Meng, L., Sanseverino, E. R., Luna, A., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.003 · Cited by 415
Sun, Q., Han, R., Zhang, H., Zhou, J., & Guerrero, J. M. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2412779 · Cited by 401
A Survey on Energy Internet: Architecture, Approach, and Emerging Technologies
Wang, K., Yu, J., Yu, Y., Qian, Y., Zeng, D., Guo, S., Xiang, Y., & Wu, J. (2018) · IEEE Systems Journal · doi:10.1109/jsyst.2016.2639820 · Cited by 374
Ahumada, C., Cardenas, R., Saez, D., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2461190 · Cited by 343
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
Chen, Q., Liu, N., Hu, C., Wang, L., & Zhang, J. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2626302 · Cited by 130
Gao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“Additionally, a common distributed dc microgrid system built only with wind renewable generation resources has to rely on elements such as batteries to maintain the dc-link stability considering the intermittent nature of wind energy; islanding operation further complicates the scenario [19],[20].”
BackgroundSelf-citationZhao, H., Zhu, T., Cheng, D., Li, B., Ding, J., & Li, Y. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0656 · Cited by 19
Haritha, G., Kumaravel, S., & Ashok, S. (2018) · 2018 2nd International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2018.8356290 · Cited by 5
Solid state transformer for wind power interfacing
Tom, B. M., & Ashok, S. (2017) · 2017 IEEE International Conference on Signal Processing, Informatics, Communication and Energy Systems (SPICES) · doi:10.1109/spices.2017.8091314 · Cited by 3
“The SST technology was continually growing and different models were proposed for SST with intelligent control circuits [6]–[8].”
MethodItoh, J.-I., Aoyagi, K., & Nakanishi, T. (2017) · 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia) · doi:10.1109/ifeec.2017.7992060 · Cited by 3
“As one of the solutions to reduce the volume and the weight of the transformer, Solid-State Transformer (SST) has been researched actively [6-8].”
Background
Metadata
- Authors
- Yu, X., She, X., Ni, X., & Huang, A. Q.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-08
- Volume
- 29
- Issue
- 8
- Pages
- 4414-4425
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1991562391
- Cited by
- 145
- References
- 3
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.