The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Accurate Pseudoempirical Model of Winding Loss Calculation in HF Foil and Round Conductors in Switchmode Magnetics
Abstract
When operating higher up in frequency, the copper losses in transformer windings will significantly rise due to enhanced skin and proximity effect. This leads to a high need to develop new methods to accurately evaluate winding losses at higher frequencies. This paper investigates the effect of different geometrical parameters at a wide range of frequencies in order to propose a pseudoempirical formula for winding loss calculation in high-frequency transformers. A comprehensive analysis of the edge effect and ac resistance is done by performing more than 12 300 2-D finite element simulations on foil and round conductors. Unlike previous studies which mostly focused on specific case studies with limited applications, this model provides very high accuracy, especially where the most common analytical models drastically underestimate the winding losses, with a wide-range applicability which could be of interest for designers to avoid time consuming FEM simulation without compromising with the accuracy. Several transformers are built and the model is experimentally verified with a good agreement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The primary design challenge for high-power MFTs is to balance the competing objectives including reliable electrical insulation, high efficiency, high power density, and superior thermal performance [2-7].”
From Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters (2021) · cites this paper as [4]
Citations
Cites
Optimizing the AC resistance of multilayer transformer windings with arbitrary current waveforms
Hurley, W. G., Gath, E., & Breslin, J. G. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.838110 · Cited by 368
Research works printed but not linked: 28
- 10.1109/PESC.2000.880550 · DOI
- 10.1142/S0218126695000370 · DOI
- flanagan, 1992, Handbook of Transformer Design and Applications
- 10.1109/TMAG.2005.852938 · DOI
- 10.1109/PESC.1993.472055 · DOI
- 10.1109/20.364775 · DOI
- 10.1109/TMAG.2009.2018624 · DOI
- colonel, 2011, Transformer and Inductor Design Handbook
- 10.1109/IAS.1992.244438 · DOI
- 10.1109/PESC.1990.131268 · DOI
- ferreira, 1992, aanalytical computation of ac resistance of round and rectangular litz wire windings, Electric Power Applications IEE Proceedings B [see also IEE Proceedings-Electric Power Applications], 139, 21, 10.1049/ip-b.1992.0003 · DOI
- 10.1109/63.903999 · DOI
- 10.1109/20.34385 · DOI
- 10.1109/PESC.1989.48591 · DOI
- 10.1109/IPEMC.2012.6258820 · DOI
- 10.1109/T-AIEE.1940.5058083 · DOI
- 10.1109/IECON.2010.5675240 · DOI
- 10.1109/20.999124 · DOI
- 10.1049/piee.1966.0236 · DOI · Paper page
- ortiz, 2010, 1 megawatt, 20 khz, isolated, bidirectional 12kv to 1.2kv DC-DC converter for renewable energy applications, Proc Int Power Electron Conf, 3212
- 10.1109/PESC.2004.1355834 · DOI
- 10.1109/20.706513 · DOI
- 10.1109/TIE.2012.2189543 · DOI
- 10.1109/APEC.1999.749510 · DOI
- 10.1109/APEC.2002.989241 · DOI
- 10.1109/PESC.2005.1581762 · DOI
- 10.1109/63.17944 · DOI
- 10.1201/9781420027280 · DOI
Cited by
Sorted by citations
Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
Bahmani, M. A., Thiringer, T., & Kharezy, M. (2016) · 2016 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2016.7468297 · Cited by 45
Self-citationInfluence of Phase-Shifted Square Wave Modulation on Medium Frequency Transformer in a MMC Based SST
Agarwal, R., Martin, S., & Li, H. (2020) · IEEE Access · doi:10.1109/access.2020.3042935 · Cited by 7
Metadata
- Authors
- Bahmani, M. A., Thiringer, T., & Ortega, H.
- Affiliations
- Chalmers University of Technology (SE)
- ORCID
- Bahmani, M. Amin
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-08
- Volume
- 29
- Issue
- 8
- Pages
- 4231-4246
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1967205671
- Cited by
- 71
- References
- 1
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 6 · 2023: 9 · 2022: 6 · 2021: 6 · 2020: 9 · 2019: 7 · 2018: 3 · 2017: 7 · 2016: 5 · 2015: 3 · 2014: 3
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Chalmers Publication Library (Chalmers University of Technology) (submittedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Funders
- Energimyndigheten
- Universidad Carlos III de Madrid
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- winding losses, high-frequency transformer, skin effect, proximity effect, edge effects, AC resistance, copper loss, transformer design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›