Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Solid-state transformer (SST) has been regarded as one of the most important emerging technologies for traction system and smart grid application. This paper presents the system design and performance demonstration of a high-voltage SST lab prototype that works as the active grid interface in smart grid architecture. Specifically, the designs of the key components of the system, including both power stage and controller platform, are presented. In addition, the advanced control system is developed to achieve high-performance operation. Furthermore, integration issues of SST with dc microgrid are presented. Lastly, tests under different scenarios are conducted to verify the following advanced features of the presented SST technology: 1) VAR compensation; 2) voltage regulation; 3) source voltage sag operation; and 4) microgrid integration.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 1×
“enables the modular design of the power stage therefore the system can be easily extended to a higher voltage and power rating [45].”
BackgroundGuerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Pulse Width Modulation for Power Converters
Holmes, D. G., & Lipo, T. A. (2003) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546284 · Cited by 2,384
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463
Self-citationReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Self-citationA New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
Self-citationClosed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635 · cited 1×
“technique is adopted, such as power management for computers [1], fuel cell systems [4]–[6], photovoltaic generation systems [7]–[9], battery storage systems [10]–[12], flexible alter-”
Method
Research works printed but not linked: 2
- claessens, 2012, Traction transformation: A power electronic traction transformer (PETT), ABB Rev, 11
- krishnaswami, 2013, Three-port series-resonant DC-DC converters to interface renewable energy resources with bidirectional load and energy storage units, IEEE Trans Power Electron, 28, 5473
Cited by
Items 101–200 of 344
Medium Voltage Converter Inductor Insulation Design Considering Grid Requirements
Li, H., Yao, P., Gao, Z., & Wang, F. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3131602 · Cited by 25
“In [3] and [4], several inductors are connected in”
BackgroundSelf-citationChen, J., Yang, T., OLOUGHLIN, C., & O’Donnell, T. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2883266 · Cited by 24
“75% [7], [8].”
Design of a 200 kW Medium-Frequency Transformer (MFT) With High Insulation Capability
Guo, Z., Sen, S., Rajendran, S., Huang, Q., Feng, X., & Huang, A. Q. (2020) · 2020 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235985 · Cited by 23
“Input-series and output-parallel (ISOP) [1] architecture and hybrid solid- state transformer (H-SST) [2] structure are also studied to expanded the SST to higher voltage and higher power applications.”
BackgroundSelf-citationSoft-switching solid state transformer (S4T)
Chen, H., & Divan, D. M. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855455 · Cited by 27
“Even for the three-stage SST, assuming that the DAB converter always operates under ZVS conditions, the rectifier and inverter have to operate in hard switching mode and incur high switching losses [18].”
BackgroundHuang, L., Li, Y., Cui, Q., Xie, N., Zeng, J. J., & Shu, J. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105880 · Cited by 24
Design Architecture for Continuous-Time Control of Dual Active Bridge Converter
Das, D., Mishra, S., & Singh, B. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3000340 · Cited by 23
Gadelrab, R. G., Hamad, M. S., Abdel-Khalik, A. S., & Zawawi, A. E. (2015) · Journal of Energy Storage · doi:10.1016/j.est.2015.10.003 · Cited by 21
Zheng, L., Kandula, R. P., & Divan, D. M. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124346 · Cited by 20
“According to existing literature, SST is usually realized by three-stage power conversion – hard-switched rectifier and inverter coupled with dual active bridge (DAB) converter [5].”
MethodNakahara, M., Kawaguchi, Y., Furukawa, K., Kadota, M., Mabuchi, Y., & Kanoda, A. (2019) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.8.652 · Cited by 20
Solid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
A Complete Design of a High Frequency Medium Voltage Multi-Port Transformer
Shafei, A. E., Özdemir, Ş., Altın, N., Jean-Pierre, G., & Nasiri, A. (2019) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera47325.2019.8997088 · Cited by 19
“Design of High Frequency Transformers (HFTs) is more complex than the design of LFTs and requires an accurate electromagnetic and loss analysis along with insulation considerations and thermal management.”
BackgroundInfluentialWireless Power Supply Design for Precharging Circuit of SST in Railway Vehicles
Lee, E. S., Park, J.-H., Kim, M., & Han, S. H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3058415 · Cited by 19
“, high-voltage dc (HVdc) transmission as a smart transformer [6], [7], distribution systems [8]–[13], and electric vehicle [14], [15].”
BackgroundCommon-mode Electromagnetic Interference Mitigation for Solid-state Transformers
Jiang, D., Wang, Z., Chen, W., Liu, J., Zhao, X., & Sun, W. (2022) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2022.000023 · Cited by 19
Model predictive control of matrix converter based solid state transformer
Liu, Y., Liu, Y., Abu‐Rub, H., & Ge, B. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474933 · Cited by 19
“INTRODUCTION The ever-increasing technology in magnatic materials and controlled power semiconductor devices has motivated the capability of smart transformers, known as solid state transformer (SST), operating at a comparable high frequency (HF) instead of line frequency (LF) of the conventional passive transformer,…”
BackgroundPerformance analysis of electronic power transformer based on neuro-fuzzy controller
Açıkgöz, H., Keçecioğlu, Ö. F., Yıldız, C., Ganı, A., & Şekkeli, M. (2016) · SpringerPlus · doi:10.1186/s40064-016-2972-0 · Cited by 19
“…reactive power compensation, harmonic isolation and all of these advantages can be realized on a single circuit (Bifaretti et al. 2011; Dujic et al. 2013; Kang et al. 1999; Kececioglu et al. 2016; Grider et al. 2011; Xu et al. 2014; Acikgoz and Sekkeli 2014; Zhao et al. 2014; Yang et al. 2015).”
BackgroundA High-Density Single-Turn Inductor for a 6 kV SiC-based Power Electronics Building Block
Song, H., Wang, J., Xu, Y., Burgos, R. P., & Boroyevich, D. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124170 · Cited by 19
“While the magnetic design can refer to classical modeling and optimization methods [11]–[13], the insulation design is a comprehensive study comprising geometric and electricfield-grading design, dielectric and shield material selection and combination, and manufacturing process development.”
BackgroundModeling and simulation of a MMC-based solid-state transformer
Adabi, M. E., Martínez-Velasco, J. A., & Alepuz, S. (2017) · Electrical Engineering · doi:10.1007/s00202-017-0510-x · Cited by 19
A Versatile Family of Partial-Resonance Inductive-AC-Link Universal Converters
Mozaffari, K., & Amirabadi, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2882114 · Cited by 18
“Multistage ac–dc–ac–dc–ac converters [4], [5] by incorporating cascaded connections of active PWM rectifiers, isolated dc–dc converters, and PWM inverters can be constructed as a three-phase ac–ac converter to benefit from high-frequency (HF) galvanic isolation.”
BackgroundComparative analysis of MAB dc-dc converters configurations in modular smart transformer
Costa, L. F., Hoffmann, F., Buticchi, G., & Liserre, M. (2017) · 2017 IEEE 8th International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2017.7972558 · Cited by 17
“age isolation, power flow control and overload and shortcircuit protection (working as a dc breaker to protect possible load/source/microgrid connected to the LV dc-link) [1]–[5].”
BackgroundTian, J., Hu, D., Zhou, C., Yang, Y., Wu, W., Mao, C., & Wang, D. (2019) · IEEE Access · doi:10.1109/access.2019.2905006 · Cited by 13
“For the three-stage EPT in the high-voltage high-power applications, there are several promising topologies which have been researched, such as the cascaded H-bridge EPT [5]–[8], the modular multilevel converter (MMC) EPT [9], [10] and the clamping multilevel EPT [11], [12].”
BackgroundInfluentialCalculation of core losses in magnetic materials under nonsinusoidal excitation
Marín-Hurtado, A. J., Rave-Restrepo, S., & Mejía, A. E. (2016) · IEEE International Power Electronics Congress (CIEP) · doi:10.1109/ciep.2016.7530736 · Cited by 17
“The SST is expected to be the key element to develop smart grids [5], [6].”
BackgroundAsuhaimi, F. A., Bu, S., Nadas, J. P. B., & Imran, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2924488 · Cited by 17
“6kV-120V/10kVA IEMs model are used in this research [40] which result in V = 120V and Ileak = 1.”
MethodControl of single-stage AC-AC solid state transformer for power exchange between grids
Liu, Y., Wang, W., Liu, Y., Abu‐Rub, H., & Li, Y. (2016) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2016.7603708 · Cited by 16
“The intermediate HF link is the dual active bridge (DAB) isolated converter, fulfilling votlage level transform [4].”
BackgroundActive Hybrid Solid State Transformer Based on Multi-Level Converter Using SiC MOSFET
Yun, C.-G., & Cho, Y. (2018) · Energies · doi:10.3390/en12010066 · Cited by 16
Atkar, D. D., Chaturvedi, P., Suryawanshi, H. M., Nachankar, P., Yadeo, D., & Saketi, S. K. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3170285 · Cited by 16
Chen, D., Huang, A. Q., Xu, Y., Wang, F. “., & Yu, W. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049252 · Cited by 16
Self-citationDynamic model of a dual active bridge suitable for solid state transformers
Daniela, G.-A., Mejía, A. E., & Ramirez-Murrillo, H. (2016) · IEEE International Power Electronics Congress (CIEP) · doi:10.1109/ciep.2016.7530783 · Cited by 15
“This element is one of the key components that has become an emerging technology to be implemented in traction systems, the integration of renewables and smart grid applications [3].”
BackgroundCurrent balancing control for multi-port hybrid AC/DC microgrid
Xiao, Q., Jia, H., Liang, B., & He, J. (2017) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2017.8273788 · Cited by 15
High Frequency Transformer Design and Optimization using Bio-inspired Algorithms
Banumathy, J. R., & Veeraraghavalu, R. (2018) · Applied Artificial Intelligence · doi:10.1080/08839514.2018.1506969 · Cited by 15
“Research efforts on design of high/medium frequency transformers for SST applications have been widely reported in literature (Du et al. 2010; Huina, Xiaodong, and Gang 2012; Ortiz et al. 2013; She et al. 2014; Montoya, Mallela, and Balda 2015).”
BackgroundControl Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
Ouyang, S., Liu, J., Chen, X., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2885562 · Cited by 15
“Over the past decade, the single-phase SST has reached a mainstream topology, as represented by the FREEDM SST [9] and the European traction SST [3].”
BackgroundChen, J., Zhu, R., Ibrahim, I., O’Donnell, T., & Liserre, M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2993927 · Cited by 15
“7% [13], [14] and has strict current limitations to avoid overload damage [15].”
BackgroundSensorless Control of Dual-Active-Bridge Converter with Reduced-Order Proportional-Integral Observer
Nguyen, D., Nguyễn, Đ. H., Funabashi, T., & Fujita, G. (2018) · Energies · doi:10.3390/en11040931 · Cited by 14
“The control system reported in [17,18] received the relevant data from the front-end rectifier, which means that the control bandwidth will be dependent on the communication speed.”
BackgroundWang, Q., & Liang, D. (2016) · International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2016.7476340 · Cited by 14
Smart distribution system Volt/VAR control using the intelligence of smart transformer
Gabbar, H. A., & Sayed, K. (2016) · IEEE International Conference on Smart Energy Grid Engineering (SEGE) · doi:10.1109/sege.2016.7589499 · Cited by 13
“Besides the advantage of its reduced size and weight due to the high frequency (HF) transformer [5-7], the SST will make use of state-of-the-art Power Electronics devices that will help it achieve efficiency comparable to that of a regular transformer of the same ratings.”
BackgroundMeng, Y., Sun, J., Duan, Z., Jia, F., Wang, X., & Wang, X. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3091996 · Cited by 13
“With the continuous penetration of renewable energy, power electronic transformer (PET) has been widely studied in many fields such as traction [11], [12], renewable energy [13], [14], and smart grids [15].”
BackgroundDesign and implementation of a PI-PBC to manage bidirectional power flow in the DAB of an SST
López-Rodríguez, K., Gil-González, W., & Mejía, A. E. (2022) · Results in Engineering · doi:10.1016/j.rineng.2022.100437 · Cited by 13
Wei, T., Cervone, A., & Dujić, D. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131324 · Cited by 13
Rahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3137720 · Cited by 13
Zuo, Z., Yao, C., Dissado, L. A., Chalashkanov, N. M., & Dodd, S. J. (2017) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2017.006895 · Cited by 13
“However the emergence of power electronic technologies [5-10] has posed several new problems because of their highly compact configurations [5, 11], dramatically larger thermal dissipation [5, 12-14], very rapid polarity changes (high dv/dt) and high repetition frequencies of applied field pulses [5-7] far in excess o…”
BackgroundLi, Z., Xu, J. Q., Wu, P., Li, G., Wang, K., Yang, Y., & Du, J. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3227269 · Cited by 12
“W ITH the integration of renewable energy resources, electric vehicles, and energy storage systems [1], [2], power electronic transformers (PET) [3], [4], [5] have been widely”
BackgroundPower electronic interface converter for resource efficient buildings
Roasto, I., Rosin, A., & Jalakas, T. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216617 · Cited by 12
“Moreover, through a communication bus, a supervision and control of subsystems can be performed [25][26].”
BackgroundA Control Strategy for Solid-State Transformers With Coupled Load Disturbance Attenuation Ability
Sarda, R., Rodríguez, E., Gorla, N. B. Y., Farivar, G. G., Pou, J., Li, Y. H., Vaisambhayana, S., & Tripathi, A. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3346687 · Cited by 12
“The voltage balancing using CHB converters has been thoroughly studied, primarily for static reactive power compensation (Stat-Com) applications, where this topology is widely used [1], [16], [17].”
BackgroundTrapezoid current modulated DCM AC/DC DAB converter for two-stage solid state transformer
Zengin, S., & Boztepe, M. (2015) · National Conference on Electrical and Electronics Engineering (ELECO) · doi:10.1109/eleco.2015.7394538 · Cited by 12
“Hence, three-stage SST topologies have been mostly studied [6]–[8], [13], [15]–[17].”
BackgroundMa, X., Yang, X., Zhang, F., Huang, L., Li, Z., & Song, H. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930736 · Cited by 12
“In reference [3, 5], the phase shift modulation method is applied in DABs, and the LV dc link voltage is controlled by regulating all DABs with a same phase shift angle.”
MethodStudy on an novel multi-port energy router for AC-DC hybrid microgrid
Tu, C., Guan, L., Xiao, F., & Zheng, L. X. (2018) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2018.8398159 · Cited by 12
Performance and Control Strategy of Real-Time Simulation of a Three-Phase Solid-State Transformer
Almaguer, J., Cardenas, V. M., Espinoza, J., Aganza-Torres, A., & Gonzalez, M. I. (2019) · Applied Sciences · doi:10.3390/app9040789 · Cited by 12
Research of the high supply voltage quality control for solid‐state transformer
Tu, C., Xiao, F., Zheng, L. X., & Shuai, Z. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0926 · Cited by 12
Martin-Arnedo, J., González-Molina, F., Martínez-Velasco, J. A., & Adabi, M. E. (2017) · Energies · doi:10.3390/en10040521 · Cited by 11
An Overview of the Role of Solid State Transformer in Smart Grid
Kadandani, N. B., Dahidah, M., & Ethni, S. (2021) · International Renewable Energy Congress · doi:10.1109/irec52758.2021.9624767 · Cited by 11
Three-Leg Integrated Stage AC–DC Solid-State Transformer Feasible for MV Railway Applications
Honório, D. D. A., de Araújo, J. W. M., Barreto, L. H. S. C., & Oliveira, D. S. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3069129 · Cited by 11
Li, H., Gao, Z., Yang, Z., Nie, C., Wang, F., & Kao, M. H. (2022) · Applied Power Electronics Conference · doi:10.1109/apec43599.2022.9773522 · Cited by 9
“In [4-6], step-up transformers are used to generate the MV ac grid from the low voltage (LV) ac grid and passive loads are used at the other terminals (ac or dc) of the MV converters to consume power.”
MethodSelf-citationAnalysis of electromagnetic force for medium frequency transformer with interleaved windings
Huang, P., Mao, C., & Wang, D. (2017) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2016.1586 · Cited by 11
Liu, Y., Liu, Y., Abu‐Rub, H., Ge, B., Balog, R. S., & Xue, Y. S. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855250 · Cited by 11
“The result is a reduction of the transformer volume and weight, which increases power density, while achieving direct connection to medium voltage (MV) [1]-[3].”
BackgroundDevelopments in voltage dip research and its applications, 2005–2015
Bagheri, A., & Bollen, M. (2016) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp.2016.7783428 · Cited by 10
Design of Variable Inductor for Powertrain DC-DC Converter
Beraki, M., Trovão, J. P. F., & Perdigão, M. S. (2019) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2019.8781250 · Cited by 10
“Nanocrystalline core materials can result in smaller and efficient inductors, nonetheless, they are expensive and they have limited shapes and sizes [31].”
BackgroundOuyang, S., Liu, J., Wang, X., Song, S., Hou, X., & Wu, T. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7168166 · Cited by 10
Wang, Z.-H., Zhang, J.-M., & Sheng, K. (2016) · Journal of Power Electronics · doi:10.6113/jpe.2016.16.3.861 · Cited by 11
Design and Control of a 13.2 kV/10 kVA Single-Phase Solid-State-Transformer with 1.7 kV SiC Devices
Lim, J.-W., Cho, Y., Lee, H., & Cho, K.-Y. (2018) · Energies · doi:10.3390/en11010201 · Cited by 10
An Aggregated Energy Management Methodology for Air Conditioning System With DAB Converter
Das, D., Mishra, S., & Singh, B. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3124161 · Cited by 10
Advanced modeling of solid state transformer
Adabi, M. E. (2018) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-113997 · Cited by 10
An Overview of the Role of Solid State Transformer in Grid Connected Wind Farms
Kadandani, N. B., Dahidah, M., & Ethni, S. (2021) · International Renewable Energy Congress · doi:10.1109/irec52758.2021.9624851 · Cited by 9
Nonlinear characteristics of DAB converter and linearized control method
Tong, A., Hang, L., Li, G., & Huang, J. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341031 · Cited by 9
“INTRODUCTION As a promising topology for various applications such as distributed generators (DGs)[1], solid-state transformer (SST)[2], and battery storage system[3] etc.”
BackgroundLi, Z., Yang, X., Tao, H., Zheng, T. Q., You, X., & Kobrle, P. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8913048 · Cited by 9
“Recently, numerous EER topologies were studied for integrating the medium-voltage (MV) AC grid and lowvoltage (LV) DC-link in the published literatures [3, 4].”
BackgroundA single‐stage AC‐AC solid‐state transformer with ZVS operation
Wang, H., Xu, M. F., Zhang, Y., Sun, Y., Zhang, G., Blaabjerg, F., Liang, X. P., Liu, Y., & Feng, J. (2020) · IET Power Electronics · doi:10.1049/pel2.12033 · Cited by 9
Smart Transformer Connected to Medium Voltage Grid Through LCL Filter
Helali, H., & Khedher, A. (2020) · International Renewable Energy Congress · doi:10.1109/irec48820.2020.9310435 · Cited by 9
Smith, C., & Haque, M. E. (2020) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias44978.2020.9334924 · Cited by 9
“It is demonstrated in [12] that an array of stacked SST “modules” is viable with sufficient balancing control between modules [1].”
BackgroundInfluentialModular EV Fast Charging Station Architectures based on Multiphase-Medium-Frequency Transformer
Hoffmann, F., Camurça, L., & Liserre, M. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591772 · Cited by 9
“Recently in the Smart transformer realization, the concept of avoiding a LFT, by a modular direct MV-conection, has become popular [6] [7].”
BackgroundAkbariavaz, K., Fazel, S. S., & Khosravi, M. (2021) · IET Power Electronics · doi:10.1049/pel2.12158 · Cited by 9
“Also, in order to fulfil the requirements of the medium-voltage highpower applications, modular multilevel converters [9] and CHB topology [10] are proposed and developed.”
Modular Power Converters for Smart Transformer Architectures
Costa, L. F. (2019) · MACAU: Open Access Repository of Kiel University (University Library Kiel) · Cited by 9
Li, Z., Li, Q., Han, Y., Hong, R., Tang, Y., Ren, H., & Wang, Z. (2024) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2024.3418390 · Cited by 8
Hybrid bidirectional DC/DC converter: Mutual control and stability analysis
Liu, H., Cui, S., Zhang, H., Hu, Y., Xue, Y., & Liu, C. (2022) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2021.00260 · Cited by 8
Deng, Y., Yin, S., Chen, J., & Song, W. (2022) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac56338.2022.9959445 · Cited by 8
“Thus, it is widely used in DC microgrids [1], energy storage systems [2]-[3], and power traction systems [4].”
MethodXu, J., Xu, L. W., Wang, X., Xie, Y., He, Y., & Ruan, X. (2020) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg48541.2020.9244308 · Cited by 8
“Besides, an input-series-output-parallel (ISOP) configuration is adopted in [5], where the high-voltage system is formed by several lower-voltage modules.”
MethodA Novel Hybrid Multilevel Converter for Medium Voltage Applications
Ansari, M. S., & Shukla, A. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379419 · Cited by 8
“The other dc-dc converter based on the series-parallel structure has complexity in the design of transformer and fault blocking [8][9].”
BackgroundCai, X., Zhang, J., Shi, G., Cai, X., Zhou, J., Li, Z., Wang, J., & Zang, J. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797182 · Cited by 8
“The classic topology of SST is based on cascaded H-bridge (CHB) as its input stage, which could boost the converter voltage to match the medium voltage AC (MVAC) grid[3].”
BackgroundLi, Y., Qin, K., Mu, S., & Yin, J. (2024) · AIP Advances · doi:10.1063/9.0000620 · Cited by 7
Optical Ultrasonic Detection for Partial Discharge Under Pulsed High Voltage
Jiang, J., He, Y., Song, Y., Wu, Q., & Wang, Q. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3472790 · Cited by 7
“As the core component of PET, a high-frequency transformer (HFT) not only plays the similar voltage transformation and isolation role as a traditional power frequency transformer but also shows the advantages of small size, lightweight, and high power density [5], [6].”
BackgroundOptimal allocation and technoeconomic analysis of solid state transformer in distribution network
Kala, H., Rawat, M. S., & Uniyal, A. (2025) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2025.110417 · Cited by 7
Series inductance design of dual‐active‐bridge converter: ZVS range with practical considerations
Kirsten, A. L., Fraytag, J., Cúnico, L. M., de Oliveira, T. H., Carloto, F. G., & Costa, M. A. D. (2022) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3249 · Cited by 7
“From (14), one can define the complete voltage response in the capacitance as (16), where the solution is given by (17).”
BackgroundDesign and Experimental Analysis of a Modular Smart Transformer Architecture
Costa, L. F., Ko, Y., & Liserre, M. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362128 · Cited by 7
Multiple objectives tertiary control strategy for solid state transformer interfaced DC microgrid
Yu, X., Ni, X., & Huang, A. Q. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954022 · Cited by 7
“Due to the limited space, the more details for SST topology and its control can be referred to [7][9][10].”
BackgroundSelf-citationARM+FPGA platform to manage solid-state-smart transformer in smart grid application
Nila-Olmedo, N., Mendoza-Mondragón, F., Espinosa-Calderon, A., & Moreno (2016) · International Conference on ReConFigurable Computing and FPGAs (ReConFig) · doi:10.1109/reconfig.2016.7857155 · Cited by 7
“This work was supported mainly by the United State Agency for the International Development (USAID-Mexico, FOG #: AID – 523-F-14-00003).”
MethodInfluentialSmart Transformer-based Hybrid LVAC and LVDC Interconnected Microgrid
Das, D., Hrishikesan, V. M., & Kumar, C. (2018) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2018.8635923 · Cited by 7
“In [7]–[9], investigation on the integration and power management of ST interfaced AC microgrids along with issues like DG integration, reverse power flow, stability and voltage regulation are analysed.”
BackgroundSolid state transformers with multilevel inverters
Kabalcı, E. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-90217-5.00005-8 · Cited by 7
Robustness of Smart Transformer Based-on Sliding Mode Controller under Grid Perturbations
Helali, H., & Khedher, A. (2021) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd52085.2021.9429505 · Cited by 7
Efficiency Enhancement of DC Solid-State Transformers by Dynamically Adjusting Active Cells
Weng, H., Jiang, Y., Chen, M., Hu, C., Krein, P. T., & Xu, D. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3311485 · Cited by 7
“High-efficiency bidirectional dc/dc converters that include dual-active-bridge converters (DAB), LLC , and CLLC resonant converters [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15] are being explored to support DCSSTs. Wide bandgap semiconductor devices, such as SiC MOSFET s, have been…”
BackgroundMishra, D. K., Abbasi, M. H., Eskandari, M., Paudel, S., Sahu, S. K., Zhang, J., & Li, L. (2024) · Applied Sciences · doi:10.3390/app14051915 · Cited by 7
Comparison of four power electronic transformer topologies on unbalanced load correction capacity
Ouyang, S., Liu, J., Wang, X., Song, S., & Hou, X. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310183 · Cited by 7
Application of Solid-State Transformers in a Novel Architecture of Hybrid AC/DC House Power Systems
Bignucolo, F., & Bertoluzzo, M. (2020) · Energies · doi:10.3390/en13133432 · Cited by 8
Rodriguez, L. A. G., Balda, J. C., Mallela, A., & Mejía, A. E. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310508 · Cited by 6
“One of the most helpful and promising PEI in the future power grids is the so-called solid-state transformer (SST), which has been proposed to replace the bulky fundamental-frequency transformers for several applications [1]–[7].”
BackgroundJeelani, N., & Bhat, A. H. (2023) · Electrical Engineering · doi:10.1007/s00202-023-02025-9 · Cited by 6
“The multi-stage SST that employs front-end rectifiers, isolated DC–DC converters, and DC–AC inverters at the load side offers the highest level of functionality and control flex-123 ibility [7, 8].”
Sensorless power balance control for cascaded multilevel converter based solid state transformer
Shanshan, W., Wang, Y., & Yifei, L. (2015) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2015.7385355 · Cited by 6
“Three stages SST has been warmly studied in recent years [2]-[4], as shown in Fig.”
BackgroundBi-directional DCM DAB inverter for SST applications
Zengin, S., & Boztepe, M. (2014) · International Symposium on Fundamentals of Electrical Engineering · doi:10.1109/isfee.2014.7050576 · Cited by 6
Solid State Transformer based on cascade multilevel converter for distribution network
Rana, M. M., Rahman, R., & Rahman, M. M. (2016) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2016.7853973 · Cited by 6
“…termed as solid state transformer (SST) has been developed which along with stepping up or down voltage level provides some extra benefits such as voltage regulation, power factor correction, var compensation, active power control fault isolation, reduction of size, availability of LVDC…”
BackgroundEfficiency/cost trade-off design of a multiple-active-bridge converter for smart transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341163 · Cited by 6
Guan, J., Xu, Y., Zhang, M., & Zhang, X. (2018) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2018.8601937 · Cited by 6
“As the isolation stage of PET, it realizes electrical isolation protection and power control.”
BackgroundInfluentialSmart Transformers Performance Study Using SPWM Control under Normal and Disturbed Operation Cases
Helali, H., Bouallegue, A., & Khedher, A. (2019) · International Conference on Sciences and Techniques of Automatic Control and Computer Engineering · doi:10.1109/sta.2019.8717299 · Cited by 6
Design and software implementation of solid state transformer
Hassan, R. F. (2018) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i3.16423 · Cited by 6
“Employing the high voltage semiconductor devices based on wide – bandgap substances like 4H – SiC, leads to the appearance of the third version of the SST configuration [9] [13] [20-21].”
BackgroundVoltage Balance Switching Scheme for Series-Connected SiC MOSFET LLC Resonant Converter
Cha, H.-R., & Kim, R.-Y. (2019) · Energies · doi:10.3390/en12204003 · Cited by 6
Design Considerations of Series-Connected Devices Based LLC Converter
Yoon, D., Lee, S.-M., & Cho, Y. (2020) · Energies · doi:10.3390/en13010264 · Cited by 5
Metadata
- Authors
- She, X., Yu, X., Wang, F., & Huang, A. Q.
- Affiliations
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-08
- Volume
- 29
- Issue
- 8
- Pages
- 3982-3996
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2173928183
- Cited by
- 324
- References
- 56
- Citations by year
- 2026: 4 · 2025: 15 · 2024: 19 · 2023: 24 · 2022: 26 · 2021: 23 · 2020: 35 · 2019: 40 · 2018: 41 · 2017: 38 · 2016: 28 · 2015: 25 · 2014: 6
- FWCI
- 17.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- North Carolina State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, smart grid, high-voltage power conversion, power stage design, advanced control systems, reactive power compensation, voltage regulation, traction systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.