Design of a 200 kW Medium-Frequency Transformer (MFT) With High Insulation Capability
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This paper presents the design of a 200-kW medium-frequency transformer (MFT) based on low loss magnetic core (FINEMET® FT-3TL). Parallel-concentric winding structure is utilized to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel insulation structure with two-layer 3D printed bobbins is further proposed. The developed MFT achieves a power density higher than 19 kW/L. The electrical insulation system is tested at AC peak 14 kV voltage and DC 25kV voltage. In addition, the partial discharge test is conducted at AC 8.5kV peak voltage to ensure a partial discharge (PD)-free design. Finally, the MFT is applied to a medium voltage solid-state transformer (SST) to verify the design.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These designs have power rating exceeding 50 kW, and the operating frequency is in the range of 1.75 kHz and 22 kHz [8-14].”
From Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters (2021) · cites this paper as [12]
In the citing paper
“Previous research [11], [12], [15], [16] investigated the optimal design methodologies for MFTs.”
From Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters (2021) · cites this paper as [12]
In the citing paper
“The methodologies have the aim of reaching the best MF transformer for a given power converter topology, by optimizing transformer efficiency, weight, transformer leakage and magnetizing inductances at the same time.”
From Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters (2021) · cites this paper as [12]
Citations
Cites
Improved Core-Loss Calculation for Magnetic Components Employed in Power Electronic Systems
Muhlethaler, J., Biela, J., Kolar, J. W., & Ecklebe, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162252 · Cited by 535
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324 · cited 2×
“Input-series and output-parallel (ISOP) [1] architecture and hybrid solid- state transformer (H-SST) [2] structure are also studied to expanded the SST to higher voltage and higher power applications.”
BackgroundSelf-citation100 kW, 10 kHz Medium-Frequency Transformer Design Optimization and Experimental Verification
Mogorovic, M., & Dujic, D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2835564 · Cited by 274 · cited 1×
“The expressions of three types heat transfer process can be simplified as [6]:”
BackgroundDesign and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2637827 · Cited by 143
Du, Y., Baek, S., Bhattacharya, S., & Huang, A. Q. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5674828 · Cited by 120
Self-citationEvaluation of topologies and optimal design of a hybrid distribution transformer
Burkard, J., & Biela, J. (2015) · 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe) · doi:10.1109/epe.2015.7309097 · Cited by 79
Bahmani, M. A., Thiringer, T., & Kharezy, M. (2016) · 2016 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2016.7468297 · Cited by 45
Transient thermal model of a medium frequency power transformer
Villar, I., Viscarret, U., Etxeberria‐Otadui, I., & Rufer, A. C. (2008) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2008.4758096 · Cited by 44 · cited 1×
“With the design of air channels, the equivalent thermal resistance between the core or winding and the fluid is a combination of the convection and radiation heat transfer resistances [14].”
BackgroundMedium-Voltage SiC-Based Converter Laminated Bus Insulation Design and Assessment
Xu, Y., Feng, X., Wang, J., Gao, C., Burgos, R., Boroyevich, D., & Hebner, R. E. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2922332 · Cited by 41 · cited 1×
“An approximate lumped circuit model can be used to describe the E-field distribution inside the MFT [11].”
MethodSelf-citation
Research works printed but not linked: 2
- 2014, FINEMET FT-3TL F/RT Series Core
- venkatachalam, 2002, Accurate prediction of ferrite cores loss with nonsinusoidal waveforms using only Steinmetz parameters, Proc IEEE Workshop Comput Power Electron, 36
Cited by
Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
“For the parallel-concentric winding structure, the wellcoupled layout of the primary and secondary windings creates a challenge for achieving good electrical insulation [40].”
BackgroundSelf-citationHardware Design of a 13.8-kV/3-MVA PV Plus Storage Solid-State Transformer (PVS-SST)
Xu, W., Guo, Z., Vetrivelan, A., Yu, R., & Huang, A. Q. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3082033 · Cited by 78
Self-citationCharacterization of Partial Discharges in High-Frequency Transformer Under PWM Pulses
Guo, Z., Huang, A. Q., Hebner, R., Montanari, G. C., & Feng, X. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3169747 · Cited by 76
Self-citationIlahi, T., Izhar, T., Qaisar, S. M., Shami, U. T., Zahid, M., Waqar, A., & Alzahrani, A. (2023) · IEEE Access · doi:10.1109/access.2023.3255780 · Cited by 39
A Differential-Mode Isolated AC/AC Converter
Gupta, S., & Mazumder, S. K. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3292983 · Cited by 30
“TheType A configured ac/ac converter is generally realized using a folding and an unfolding stage to interface the dc/dc converter [1], [12], [13], [14].”
Method
Metadata
- Authors
- Guo, Z., Sen, S., Rajendran, S., Huang, Q., Feng, X., & Huang, A. Q.
- Affiliations
- The University of Texas at Austin (US)
- Venue
- 2020 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2020-10-11
- Pages
- 3471-3477
- OpenAlex
- W3096667343
- Cited by
- 23
- References
- 15
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 1
- FWCI
- 5.62
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- medium frequency transformer, electrical insulation, partial discharge, leakage inductance, power density, solid-state transformer, high-voltage insulation testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a 200 kW Medium-Frequency Transformer (MFT) With High Insulation Capability. https://app.cochat.ai/papers/10.1109/ecce44975.2020.9235985
- The paper
- Guo, Z., Sen, S., Rajendran, S., Huang, Q., Feng, X., & Huang, A. Q. (2020). Design of a 200 kW Medium-Frequency Transformer (MFT) With High Insulation Capability. 2020 IEEE Energy Conversion Congress and Exposition (ECCE). https://doi.org/10.1109/ecce44975.2020.9235985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.