Extended Boost Active-Switched-Capacitor/Switched-Inductor Quasi-Z-Source Inverters
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper proposes a new topology named the active-switched-capacitor/switched-inductor quasi-Z -source inverter (ASC/SL-qZSI), which is based on a traditional qZSI topology. Compared to other qZSI-based topologies under the same operating conditions, the proposed ASC/SL-qZSI provides higher boost ability, requires fewer passive components such as inductors and capacitors, and achieves lower voltage stress across the switching devices of the main inverter. Another advantage of the topology is its expandability. If a higher boosting rate is required, additional cells can easily be cascaded at the impedance network by adding one inductor and three diodes. Both the simulation studies and the experimental results obtained from a prototype built in the laboratory validate proper operation and performance of the proposed ASC/SL-qZSI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, F. Z. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808920 · Cited by 3,228
Axelrod, B., Berkovich, Y., & Ioinovici, A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916403 · Cited by 1,379 · cited 2×
“Both the C-switching structure with two capacitors and two-three diodes, and the L-switching structure with two inductors and two-three diodes were proposed [19].”
BackgroundMethodVoltage Multiplier Cells Applied to Non-Isolated DC–DC Converters
Prudente, M., Pfitscher, L. L., Emmendoerfer, G., Romaneli, E. F., & Gules, R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915762 · Cited by 750 · cited 1×
“To enhance the boosting ability, additional cells are cascaded at the generalized switched-inductor and switched-capacitor ZSI or nonisolated dc–dc converter [20], [24], [25].”
BackgroundSwitched Inductor Z-Source Inverter
Zhu, M., Yu, K. S., & Luo, F. L. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2046676 · Cited by 637 · cited 1×
“In [21]–[23], several types of switched-inductor impedance networks coupled to a ZSI or qZSI were introduced.”
Background$Z$-Source Inverter for Residential Photovoltaic Systems
Huang, Y., Shen, M., Peng, F. Z., & Wang, J. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.882913 · Cited by 504 · cited 1×
“The ZSI has been applied to electric vehicles and photovoltaic (PV) power generation systems due to its wide range of obtainable voltage [9]–[11].”
BackgroundApplication of Z-Source Inverter for Traction Drive of Fuel Cell—Battery Hybrid Electric Vehicles
Peng, F. Z., Shen, M., & Holland, K. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897123 · Cited by 370 · cited 1×
“The ZSI has been applied to electric vehicles and photovoltaic (PV) power generation systems due to its wide range of obtainable voltage [9]–[11].”
BackgroundLiu, J., Hu, J., & Xu, L. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904219 · Cited by 287 · cited 2×
“For the purpose of exact comparison, the ac-side circuit of the four topologies is simplified as the equivalent dc load, which is represented by an inductive load impedance (Zl = Rl + sLl) [2].”
BackgroundAnalysis and PWM Control of Switched Boost Inverter
Ravindranath, A., Mishra, S. K., & Joshi, A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230595 · Cited by 273 · cited 1×
“Voltage-fed or current-fed switched inverter topologies for reducing the number of passive components in the impedance network have been proposed in [26] and [27].”
BackgroundZhou, Y., Liu, L., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2219556 · Cited by 242
Abu-Rub, H., Iqbal, A., Moin Ahmed, S., Peng, F. Z., Li, Y., & Baoming, G. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2196059 · Cited by 239 · cited 1×
“Thus, several effective control methods for qZSI-based grid-connected PV power generation and electric vehicle applications have been proposed [13]–[18].”
Method
Cited by
A review of galvanically isolated impedance-source DC-DC converters
Chub, A., Vinnikov, D., Blaabjerg, F., & Peng, F. Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2453128 · Cited by 243
High Step-Up Quasi-Z Source DC–DC Converter
Haji-Esmaeili, M. M., Babaei, E., & Sabahi, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2810884 · Cited by 226
“In [28], a combined switched-inductors switched-capacitor method has been employed to improve the QZS converter.”
BackgroundMethod
Metadata
- Authors
- Ho, A.-V., Chun, T.-W., & Kim, H.-G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-10
- Volume
- 30
- Issue
- 10
- Pages
- 5681-5690
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2043987852
- Cited by
- 197
- References
- 11
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.