Modeling and Control of a Multiport Power Electronic Transformer (PET) for Electric Traction Applications
The DOI matches its Crossref record; 41 of the 42 references it cites were found in a registry or an index.
Abstract
This paper proposes a multiport power electronic transformer (PET) topology with multiwinding medium-frequency transformer (MW-MFT) isolation along with the associated modeling analysis and control scheme. The power balance at different ports can be controlled using the multiwinding transformer's common flux linkage. The potential applications of the proposed multiport PET are high-power traction systems for locomotives and electric multiple units, marine propulsion, wind power generation, and utility grid distribution applications. The complementary polygon equivalent circuit modeling of an MW-MFT is presented. The current and power characteristics of the virtual circuit branches and the multiports with general-phase-shift control are described. The general current and power analysis for the multiple active bridge (MAB) isolation units is investigated. Power decoupling methods, including nonlinear solution for power balancing are proposed. The zero-voltage-switching conditions for the MAB are discussed. Control strategies including soft-switching-phase-shift control and voltage balancing control based on the power decoupling calculations are described. Simulations and experiments are presented to verify the performance of the proposed topology and control algorithms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932 · cited 1×
“3) When the dc voltages of the primary side are the same, and the secondary side dc voltages are the same, respectively, the extended-phase-shift control could be used for ZVS soft-switching [40], [41].”
BackgroundA New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 1×
“A modular multilevel converter was also used as the primary converter as proposed in [19].”
MethodInoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669 · cited 1×
“To increase the power density and improve the performance of traction converter, as well as enhance the availability and flexibility of the electric traction system, medium-frequency transformer (MFT) isolated power converters can be used [4]–[6].”
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 1×
“The structure of secondary side dc buses in parallel can drive a single load, however, it is difficult to balance the dc voltages with two or more different loads [22]–[26].”
BackgroundFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501 · cited 1×
“Some research works for multiport PETs have been published on circuit topologies [27] and dc-voltage balancing methods [34], [35] with singlephase shift (SPS) [31] control, but there has been little work on multiwinding transformer modeling for PET, multiport power analysis, and zero-voltage switching (ZVS) control.”
BackgroundFamily of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488 · cited 15×
“These medium frequency voltages are isolated using MW-MFT, and rectified to produce several output dc links.”
BackgroundInfluentialPower Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 1×
“ABB and BOMBARDIER suggested configurations with primary-seriessecondary-parallel-connected dc-links as traction converters for high-speed trains [20], [21], as shown in Fig.”
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“2416212 This type of power converter using an MFT for voltage matching and electrical isolation is also known as a power electronic transformer (PET) or solid state transformer [6], [7].”
MethodResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Cited by
Items 201–229 of 229
2016 Index IEEE Transactions on Power Electronics Vol. 31
(2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3272431
Isolated Balanced Charger using Multi-Active Bridge (MAB-IBC)
Sabry, O. H., Khalil, A. E., El-Shenawy, A., Hamad, M. S., & Abdel-Khalik, A. S. (2023) · IEEE Conference on Power Electronics and Renewable Energy (CPERE) · doi:10.1109/cpere56564.2023.10119607
“This control technique depends on the transformers leakage inductor to control the power flow limit which introduces high circulating power at mismatched voltage amplitudes on the transformer’s sides, significantly decreasing the efficiency when compared with other more advanced control techniques [28][29][30][31][32].”
ResultDesign of Active Closed-loop Driver Chip for SiC
Ke, J., Feng, J., Huang, Y., Guan, Z., Xu, H., & Zhao, M. (2023) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2625/1/012058
“Undervoltage module circuit Generally, SiC devices can only withstand such short circuits for 10 us, so the chip protection function needs to completely shut down the SiC within 10 us after the fault occurs to avoid damaging the SiC device and related application circuits [10].”
BackgroundDesign of coils for high-power medium-frequency transformers using Grain-Oriented hot cores
Roger, D., Rossi, M., Komęza, K., Napieralska‐Juszczak, E., & Cambier, J. (2024) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-230404
Research on Topology and Control Strategy of External Energy Harvesting Hybrid Power Transformer
Zheng, X., Sang, Z., Liu, J., He, L., Dong, X., & Zou, Q. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532531
“However, simple power electronic devices are characteristic of low reliability, large construction investment, complex control circuit as well as high operation and maintenance cost in high power density application scenario [4, 5].”
BackgroundComprehensive Evaluation Method of AC/DC Distribution System with Distributed Generation
Li, J., Wang, W., Lu, J., Tang, Z., Ju, H., & Ai, P. (2024) · Power System and Green Energy Conference (PSGEC) · doi:10.1109/psgec62376.2024.10721110
“These converters and DGs feature complex control strategies and operational modes, which increase the difficulty of steady-state and transient analysis [4]-[6].”
BackgroundAlgorithm for sequences exploration and optimization of a Multi-Active-Bridge
Aguinaga, I. C., Patin, N., Gomez, P., Lanfranchi, V., & Dalbavie, J.-M. (2024) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2024.10.037
Zhen, Z., Xiaoli, M., Li, J., Yinan, H., Min, W., Qiming, W., & Gao, H. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-8820-0_6
Cao, H., Liu, J., Song, Y., Wang, S., Dai, F., Li, L., Ma, J., & Sun, Q. (2024) · International Conference on Smart Grid and Smart Cities (ICSGSC) · doi:10.1109/icsgsc62639.2024.10813857
A QAB-Based SST DC Charging System for Light Rail Transit Trains
Wang, M., & Lee, T. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861553
Liu, Z., Zhu, L., Gao, Y., Dang, Y., Zhan, C., & Ji, S. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977242
Three-phase unbalance control strategy of hybrid power transformer based on IDSOGI and Kalman filter
Tong, Z., Tang, A., Shang, Y., Ma, L., Wang, Q., Wang, Q., Ding, C., Lu, Y., & Qiu, P. (2025) · Electrical Engineering · doi:10.1007/s00202-025-03286-2
A Power Self-Decoupling Control for the Quad-Active Bridge Converter with Low-Computation Burden
Lin, C., Ma, M., Li, Y., Zhang, Y., Feng, Q., & Zhang, C. (2024) · International Academic Exchange Conference on Science and Technology Innovation (IAECST) · doi:10.1109/iaecst64597.2024.11117292
“In [19]-[20], using the Newton iteration method to solve the nonlinear equations of the QAB converter’s power can achieve decoupling control of the QAB converter.”
Self-citationExplainable AI for Fault Localization in High-Voltage Electric Marine Propulsion Systems
Sharada Prasad, N., Kuppannan, A., Kishore, K. L., Saranya, D., Tallapragada, V. V. S., & Karthikumar, K. (2025) · International Conference on Recent Innovation in Science Engineering and Technology (ICRISET) · doi:10.1109/icriset64803.2025.11254955
“Fast Fourier Transform (FFT), Wavelet Transform (WT), and Hilbert -Huang Transform (HHT) tools have been used to test the motor bearing defects, eccentricities, and converter switching abnormalities [7].”
An Enhanced Power Electronic Traction Transformer With Low-Voltage IGBTs for Railway Applications
Gupta, J., & Shukla, K. (2025) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet65155.2025.11255427
“A multi-winding MFT structure in [13] helps optimize MFT usage, but power decoupling is complex [8].”
Ma, M., Zhang, C., Yuan, X., Xiong, W., Liu, Z., Xu, Y., Wang, J., & Wang, D. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3613356
“The ESL cannot be accurately measured, because the test conditions using the previous short-circuit measurement method differ from the actual conditions of QAB converters [24], [25], [26], so that results in significant errors.”
Xu, X., Wang, M. C., Xie, D., Zhu, Y., Qiu, Q., & Ge, X. (2025) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee67631.2025.11309180
Yan, Y., Zhong, H., & Qi, Y. (2025) · International Conference on Power Engineering (ICPE) · doi:10.1109/icpe68635.2025.11407901
“Therefore, it is widely used in emerging fields such as DC microgrids [3]-[4], electric vehicles (EVs) [5]-[6], more electric aircraft (MEA) [7] and electric traction systems [8].”
Transformateurs électroniques pour applications ferroviaires
Stackler, C. (2019) · theses.fr (ABES) · doi:10.70675/5c7e1617z8dd3z4d2az8736z9626631914a5 · Cited by 1
Review on operation research of multiple-AC-port power electronic transformers
wang, X., Xu, Y., sun, Y., & tian, X. (2026) · Electric Power Systems Research · doi:10.1016/j.epsr.2026.113095
Power Converters as Enablers of Hybrid-Electric Aircraft Propulsion
Alfares, A. (2026) · Energies · doi:10.3390/en19081931
A review of power loss measurement method for high-frequency transformer
Zhu, L., Liu, Z., Dang, Y., Zhang, S., Zhang, G., & Ji, S. (2026) · Renewable Energy System and Equipment · doi:10.1016/j.rese.2026.05.002
Wang, M. C., Xie, D., Xi, H., & Ge, X. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11571863
“As a pivotal component of the power electronic transformer (PET), the cascaded H-bridge rectifier (CHBR) is widely favored for its modularity [1]-[3].”
Multiphase Flyback Converter with Clamping Circuit for Multiple-Output Converter
Thumputi, N., & Owatchaiphong, S. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597427
“…across diverse fields such as electric vehicles providing low-voltage multiple outputs for battery management systems and control units [1], renewable energy system providing non-grid-tied solution, particularly for standalone photovoltaic system providing protection against ground…”
Owatchaiphong, S., Poonsawad, K., Mungtorbua, W., Kanavittaya, A., & Thumputi, N. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597559
“Selecting a transformer regarding voltage ratio and winding configurations becomes more difficult for multiple-input multiple-output (MIMO) converters due to the complexity of magnetic parts [1] [3].”
Planar Integrated Magnetics Technology — A Review
Chakkalakkal, S., & Emadi, A. (2026) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2026.3719252
“Although often minimized, it is intentionally enhanced in phase-shifted converters to facilitate soft switching and help mitigate EMI [4], [24].”
InfluentialGe, X., Zhou, Q., Fang, X., & Chen, S. (2026) · Energies · doi:10.3390/en19204813
Liu, Z., Lingyu, Z., Dang, Y., Zhang, G., Fan, Z., & Ji, S. (2026) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecceeurope67962.2026.11737812
“Solid-state transformer (SST) is gaining increasing attentions in renewable energy collection, data center, traction power supply, and electric charging station [1]-[4].”
Yuan, L., Wang, R., Ji, S., Gao, J., Wang, J., & Zhou, X. (2026) · International Conference on Advanced Electrical and Energy Systems (AEES) · doi:10.1109/aees71194.2026.11745636
“Among various topologies, the centralized-isolation-stage PET based on the multi-active bridge (MAB) has attracted attention due to its high power density and flexible port integration [2][3].”
Metadata
- Authors
- Gu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y.
- Affiliations
- Tsinghua University (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-02
- Volume
- 31
- Issue
- 2
- Pages
- 915-927
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1970816228
- Cited by
- 221
- References
- 42
- Citations by year
- 2026: 7 · 2025: 21 · 2024: 23 · 2023: 19 · 2022: 29 · 2021: 23 · 2020: 25 · 2019: 35 · 2018: 23 · 2017: 8 · 2016: 5
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- State Key Laboratory of Control and Simulation of Power System and Generation Equipment
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- electric traction, power decoupling, power balancing, zero-voltage switching, voltage balancing control, equivalent circuit model, locomotives, electric multiple units, ship propulsion, wind power generation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.