This paper proposes a multiport power electronic transformer (PET) topology with multiwinding medium-frequency transformer (MW-MFT) isolation along with the associated modeling analysis and control scheme. The power balance at different ports can be controlled using the multiwinding transformer's common flux linkage. The potential applications of the proposed multiport PET are high-power traction systems for locomotives and electric multiple units, marine propulsion, wind power generation, and utility grid distribution applications. The complementary polygon equivalent circuit modeling of an MW-MFT is presented. The current and power characteristics of the virtual circuit branches and the multiports with general-phase-shift control are described. The general current and power analysis for the multiple active bridge (MAB) isolation units is investigated. Power decoupling methods, including nonlinear solution for power balancing are proposed. The zero-voltage-switching conditions for the MAB are discussed. Control strategies including soft-switching-phase-shift control and voltage balancing control based on the power decoupling calculations are described. Simulations and experiments are presented to verify the performance of the proposed topology and control algorithms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932 · cited 1×
“3) When the dc voltages of the primary side are the same, and the secondary side dc voltages are the same, respectively, the extended-phase-shift control could be used for ZVS soft-switching [40], [41].”
BackgroundA New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 1×
“A modular multilevel converter was also used as the primary converter as proposed in [19].”
MethodInoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669 · cited 1×
“To increase the power density and improve the performance of traction converter, as well as enhance the availability and flexibility of the electric traction system, medium-frequency transformer (MFT) isolated power converters can be used [4]–[6].”
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 1×
“The structure of secondary side dc buses in parallel can drive a single load, however, it is difficult to balance the dc voltages with two or more different loads [22]–[26].”
BackgroundFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501 · cited 1×
“Some research works for multiport PETs have been published on circuit topologies [27] and dc-voltage balancing methods [34], [35] with singlephase shift (SPS) [31] control, but there has been little work on multiwinding transformer modeling for PET, multiport power analysis, and zero-voltage switching (ZVS) control.”
BackgroundFamily of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488 · cited 15×
“These medium frequency voltages are isolated using MW-MFT, and rectified to produce several output dc links.”
BackgroundInfluentialPower Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 1×
“ABB and BOMBARDIER suggested configurations with primary-seriessecondary-parallel-connected dc-links as traction converters for high-speed trains [20], [21], as shown in Fig.”
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“2416212 This type of power converter using an MFT for voltage matching and electrical isolation is also known as a power electronic transformer (PET) or solid state transformer [6], [7].”
MethodResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Medium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249 · cited 1×
“ABB and BOMBARDIER suggested configurations with primary-seriessecondary-parallel-connected dc-links as traction converters for high-speed trains [20], [21], as shown in Fig.”
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205
Design of H-bridge multilevel active rectifier for traction systems
Cecati, C., Dell'Aquila, A., Liserre, M., & Giuseppe Monopoli, V. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816515 · Cited by 177
Characterization and Implementation of Dual-SiC MOSFET Modules for Future Use in Traction Converters
Fabre, J., Ladoux, P., & Piton, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2352863 · Cited by 161
New Configuration of Traction Converter With Medium-Frequency Transformer Using Matrix Converters
Drabek, P., Peroutka, Z., Pittermann, M., & Cedl, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2138114 · Cited by 148 · cited 1×
“In other early studies, cascaded single-phase matrix converters were used as the gridconnected converters [17], [18].”
MethodShe, X., Huang, A. Q., & Wang, G. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2142422 · Cited by 144 · cited 1×
“The structure of secondary side dc buses in parallel can drive a single load, however, it is difficult to balance the dc voltages with two or more different loads [22]–[26].”
BackgroundMerkert, A., Krone, T., & Mertens, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2294682 · Cited by 135
Ortiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126
Multilevel Converter for Traction Applications: Small-Scale Prototype Tests Results
Carpita, M., Marchesoni, M., Pellerin, M., & Moser, D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918645 · Cited by 100 · cited 1×
“In other early studies, cascaded single-phase matrix converters were used as the gridconnected converters [17], [18].”
MethodElectric Railway Traction in Europe
Steimel, A. (1996) · IEEE Industry Applications Magazine · doi:10.1109/2943.541241 · Cited by 94 · cited 1×
“S INGLE-PHASE line frequency transformers with fourquadrant power converters are commonly used for traction applications on electric locomotives and electric multiple units (EMUs) [1], [2] due to their simplicity, reliability, and low price.”
BackgroundFlexible Power Electronic Transformer
Sabahi, M., Goharrizi, A. Y., Hosseini, S. H., Sharifian, M. B. B., & Gharehpetian, G. B. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2040840 · Cited by 89 · cited 2×
“2416212 This type of power converter using an MFT for voltage matching and electrical isolation is also known as a power electronic transformer (PET) or solid state transformer [6], [7].”
MethodRepetitive Compensation of Fluctuating DC Link Voltage for Railway Traction Drives
Ouyang, H., Zhang, K., Zhang, P., Kang, Y., & Xiong, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2105283 · Cited by 83 · cited 1×
“However, they also have some obvious drawbacks including large size and weight because of low fundamental frequency and second-order harmonics of the dc output voltage [3].”
BackgroundPower Electronics Technologies for Railway Vehicles
Taufiq, J. (2007) · 2007 Power Conversion Conference - Nagoya · doi:10.1109/pccon.2007.373146 · Cited by 82 · cited 1×
“5-MVA single-output MFT was used for isolation [16].”
MethodLiu, X., Li, H., & Wang, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2200047 · Cited by 60
Nanocrystalline magnetic materials versus ferrites in power electronics
Nikolov, G. T., & Valchev, V. C. (2009) · Procedia Earth and Planetary Science · doi:10.1016/j.proeps.2009.09.209 · Cited by 52
Zheng, Z., Gao, Z., Gu, C., Xu, L., Wang, K., & Li, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2290019 · Cited by 46 · cited 3×
“It is better to use a polygon equivalent circuit instead of a simplified equivalent circuit [34] because the mutual leakage inductance of a high-power MW-MFT cannot be ignored.”
BackgroundMethodSelf-citationWang, J., Witulski, A. F., Vollin, J. L., Phelps, T., & Cardwell, G. I. (1999) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1999.749513 · Cited by 46 · cited 1×
“The circuit diagram [36], [37] of a multiwinding transformer is shown in Fig.”
MethodGeneralized nonlinear diagonal dominance and applications to asynchronous iterative methods
Frommer, A. (1991) · Journal of Computational and Applied Mathematics · doi:10.1016/0377-0427(91)90164-f · Cited by 25 · cited 1×
“Therefore, the use of the Newton iteration method and other methods like the steepest descent method is convergence [38], [39].”
MethodTraction technology for Chinese railways
Yang, Z., Huang, X., Wu, S., & Peng, H. (2010) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2010.5544523 · Cited by 22 · cited 1×
“S INGLE-PHASE line frequency transformers with fourquadrant power converters are commonly used for traction applications on electric locomotives and electric multiple units (EMUs) [1], [2] due to their simplicity, reliability, and low price.”
BackgroundMedium frequency transformer for rail application using new materials
Hoffmann, H., & Piepenbreier, B. (2011) · International Electric Drives Production Conference · doi:10.1109/edpc.2011.6085569 · Cited by 21
Incomplete Jacobian Newton method for nonlinear equations
Liu, H., & Ni, Q. (2008) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2007.12.002 · Cited by 21 · cited 1×
“Therefore, the use of the Newton iteration method and other methods like the steepest descent method is convergence [38], [39].”
MethodOutlook for SiC devices in traction converters
Ladoux, P., Mermet, M., Casarin, J., & Fabre, J. (2012) · IEEE International Conference on Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles & International Transportation Electrification Conference (ESARS-ITEC) · doi:10.1109/esars.2012.6387463 · Cited by 19 · cited 1×
“1(b) and (c), with the increasing demand of lower size/weight and better output voltage performance, especially when the efficiency for the PET is increased with silicon carbide devices and nanocrystalline magnetic materials [8]–[15].”
BackgroundEvaluation of high voltage SiC diodes in a medium frequency AC/DC converter for railway traction
Casarin, J., Ladoux, P., Chauchat, B., Dedecius, D., & Laugt, E. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264491 · Cited by 19
Soft Magnetic Properties of Nanostructured Vitroperm Alloy Powder Cores
Füzer, J., Kollár, P., Fuzerova, J., & Roth, S. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033337 · Cited by 19 · cited 1×
“1(b) and (c), with the increasing demand of lower size/weight and better output voltage performance, especially when the efficiency for the PET is increased with silicon carbide devices and nanocrystalline magnetic materials [8]–[15].”
BackgroundGeneral equivalent circuit of a multi-winding co-axial winding transformer
Sun, C., Kutkut, N. H., Novotny, D. W., & Divan, D. M. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1995.530622 · Cited by 17 · cited 1×
“The circuit diagram [36], [37] of a multiwinding transformer is shown in Fig.”
MethodModular double-cascade converter
Sankala, A., Korhonen, J., Ström, J., Luukko, J., Silventoinen, P., Komulainen, R., Sarén, H., Södö, N., & Isaksson, D. (2012) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2012.6165887 · Cited by 17
Control strategy of a multi-level converter with multi-winding MFT/HFT isolation
Gu, C., Zheng, Z., & Li, Y. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953906 · Cited by 11
Self-citationGu, C., Krishnamoorthy, H. S., Enjeti, P. N., Zheng, Z., & Li, Y. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.6.1166 · Cited by 10
Self-citationGu, C., Krishnamoorthy, H. S., Enjeti, P. N., & Li, Y. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953518 · Cited by 7
Self-citationA multi-level inverter system design with multi-winding transformer
Sarıkurt, T., Sezenoğlu, C., & Balıkçı, A. (2011) · International Aegean Conference on Electrical Machines and Power Electronics · doi:10.1109/acemp.2011.6490668 · Cited by 4 · cited 1×
“Some research works for multiport PETs have been published on circuit topologies [27] and dc-voltage balancing methods [34], [35] with singlephase shift (SPS) [31] control, but there has been little work on multiwinding transformer modeling for PET, multiport power analysis, and zero-voltage switching (ZVS) control.”
BackgroundKorhonen, J., Sankala, A., Ström, J., Luukko, J., Silventoinen, P., Komulainen, R., Sarén, H., Södö, N., & Isaksson, D. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520607 · Cited by 3
Cited by
Review on Advanced Control Technologies for Bidirectional DC/DC Converters in DC Microgrids
Xu, Q., Vafamand, N., Chen, L., Dragicevic, T., Xie, L., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2978064 · Cited by 439
“They have wide applications in automotive powertrains [22], [23], more electric aircraft distribution systems [119], [120], naval shipboard microgrids [73], [121], power electronics transformers [122], nanogrids [123], and median voltage dc applications [124], etc.”
BackgroundThe Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445
“JUNE 2016 ■ IEEE IndustrIal ElEctronIcs magazInE 55 with the additional characteristic of reducing the number of HF transformers [27] because it integrates more active bridge to a single transformer.”
BackgroundPower Electronic Transformer-Based Railway Traction Systems: Challenges and Opportunities
Feng, J., Chu, W. Q., Zhang, Z., & Zhu, Z. Q. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2685464 · Cited by 229
“In [93]–[95], two CHB-based multiport PET railway traction systems are developed by Tsinghua University,”
BackgroundLiu, J., Yang, J., Zhang, J., Nan, Z., & Zheng, Q. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679489 · Cited by 146
“In [3], Siemens and München University introduced a laboratory prototype based on the proposed M2LC ac/ac converter; Tsinghua University proposed a multiport topology with multiwinding medium-frequency transformer isolation [4]; based on 6.”
MethodRuiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 144
“This has been proposed for trains where the series-connected input side works at the catenary voltage level, while the output side of each port is connected to independent machines [67].”
Background
Metadata
- Authors
- Gu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y.
- Affiliations
- Tsinghua University (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-02
- Volume
- 31
- Issue
- 2
- Pages
- 915-927
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1970816228
- Cited by
- 221
- References
- 42
- Citations by year
- 2026: 7 · 2025: 21 · 2024: 23 · 2023: 19 · 2022: 29 · 2021: 23 · 2020: 25 · 2019: 35 · 2018: 23 · 2017: 8 · 2016: 5
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- State Key Laboratory of Control and Simulation of Power System and Generation Equipment
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- electric traction, power decoupling, power balancing, zero-voltage switching, voltage balancing control, equivalent circuit model, locomotives, electric multiple units, ship propulsion, wind power generation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.