Power and Voltage Balance Control of a Novel Three-Phase Solid-State Transformer Using Multilevel Cascaded H-Bridge Inverters for Microgrid Applications
The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Abstract
This paper presents a new application of power and voltage balance control schemes for the cascaded H-bridge multilevel inverter (CHMI)-based solid-state transformer (SST) topology. To reduce load on the controller and simplify modulation algorithm, a master-slave control (MSC) strategy is designed for the dual active bridge (DAB) stage. The master controller executes all control and modulation calculations, and the slave controllers manage only device switching and protection. Due to the inherent power and dc-link voltage unbalance in cascaded H-bridge-based SST, this paper presents a compensation strategy based on three-phase dq decoupled current controller. An optimum zero-sequence component is injected in the modulation scheme so that the three-phase grid currents are balanced. Furthermore, to tightly regulate the output voltage of all the DAB modules to target value, a dynamic reference voltage method is also implemented. With this proposed control method, the three-phase grid currents and dc-link voltage in each module can be simultaneously balanced. Finally, simulation and experimental results are presented to validate the performance of the controller and its application to microgrid SST.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“In contrast, the SST is an intelligent power electronics system with capabilities such as managing power flow, providing power quality improvement, and allowing easy connection of the distribution resources [1]–[5].”
BackgroundSelf-citationA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Research on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 5×
“This paper extends some of the control methods developed previously [20]–[22] for different applications and validates the concept by means of numerical simulations, and extensive experimental validation carried out on a 10-kV·A laboratory prototype.”
BackgroundMethodInfluentialMaharjan, L., Inoue, S., & Akagi, H. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002180 · Cited by 310
Phase-Shifted Carrier PWM Technique for General Cascaded Inverters
Naderi, R., & Rahmati, A. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921186 · Cited by 301
Maharjan, L., Yamagishi, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059045 · Cited by 278
Liu, J., Cheng, K. W. E., & Ye, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2291514 · Cited by 277 · cited 1×
“Different topologies other than DAB dc–dc converter to boost the PV source voltage are also proposed for SST in [23] and [24] but the concept is based on transformerless SST where there is no isolation transformer between input and output.”
Method
Cited by
Items 201–289 of 289
Subramanian, V., & Indragandhi, V. (2022) · Circuit World · doi:10.1108/cw-05-2021-0157 · Cited by 3
Li, L., Sun, Y., Hou, X., Zhou, K., & Su, M. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110218 · Cited by 3
A multi-layer protection scheme for MMC-power electronic transformers
Zhu, X., Zhou, N., Liao, J., Wang, Q., Luo, Y., & Yu, D. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.110786 · Cited by 3
Gao, C., Wu, P., Xu, J., Wang, K., Song, Y., & Blaabjerg, F. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3597458 · Cited by 3
Li, L., Tian, P., Yan, G., & Shen, S. (2024) · International Transactions on Electrical Energy Systems · doi:10.1155/etep/4120338 · Cited by 3
Sharma, A., Chilipi, R., & Kumar, K. V. P. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3618598 · Cited by 3
High-Frequency-Link Isolated Modular Multilevel Converter (I-M2C) Topology
Liu, C., Liu, C., Shan, R., Wang, Y., Pei, Z., & Ying, H. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590659 · Cited by 3
Self-citationArchitecture Design and Evaluation of Hybrid AC/DC Power Grids Based on Power Electronic Transformer
Yang, Y., Pei, W., Zhang, S., Ye, H., Wan, Y., & Qi, X. (2019) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2019.8881775 · Cited by 3
Li, R., Lin, H., Cai, C., Zhu, L., Yan, H., & Shu, Z. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8922078 · Cited by 3
Improved Model Predictive Control for Mitigating False Data Injection on Cascaded H-Bridge Inverters
Rao, R., Liu, Z., Wang, L., Hou, S., & He, Y. (2019) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec45492.2019.8994576 · Cited by 3
Self-citationJahan, H. K., Kurdkandi, N. V., Abapour, M., Zare, K., Hosseini, S. H., Yang, Y., & Blaabjerg, F. (2020) · Mathematics · doi:10.3390/math8101716 · Cited by 3
“This is also the case when applying HFLMIs in PV applications, where the leakage current issue is addressed.”
BackgroundHybrid Technique Based Harmonic Elimination of the Thirty-One Level Multi Level Inverter
Sridhar, K., & Prakash, R. (2022) · Wireless Personal Communications · doi:10.1007/s11277-021-09208-2 · Cited by 3
“[19] showed ANFIS as a shifting angle estimator for a harmonic optimization problem in cascade MLIs.”
BackgroundShu, L., Chen, W., & Jin, H. (2022) · IET Power Electronics · doi:10.1049/pel2.12243 · Cited by 3
Wang, D., Guan, Z., Tian, J., Mao, C., Yang, Y., & Wang, Z. (2022) · IET Power Electronics · doi:10.1049/pel2.12272 · Cited by 4
Mannen, T. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213617 · Cited by 3
Sivamani, S., Mangaiyarkarasi, S. P., & Senthilkumar, S. (2024) · Engineering Research Express · doi:10.1088/2631-8695/ad43bc · Cited by 3
Stability Boundary Characterization and Power Quality Improvement for Distribution Networks
Zhang, M., Long, Y., Guo, S., Xiao, Z., Shi, T., Xiang, X. J., & Fan, R. L. (2024) · Energies · doi:10.3390/en17246215 · Cited by 3
Güç Elektroniği Transformatörlerinin İncelenmesi ve Bir DA/DA Dönüştürücü Uygulaması
Alkul, O., & Demirbaş, Ş. (2019) · Gazi Üniversitesi Fen Bilimleri Dergisi Part C Tasarım ve Teknoloji · doi:10.29109/gujsc.556509 · Cited by 3
Stability Assessment Study for a Triple-Stage Three-Phase Solid-State Transformer
Granata, S., Leuzzi, R., Tresca, G., Bassi, E., Benzi, F., & Zanchetta, P. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9947797 · Cited by 3
“The DAB converters control the dc voltage at their secondary side, namely MVdc-link2 [2], [4].”
BackgroundMethodInfluentialReciprocating Bus in FREEDM System with Solar Farm Integration
Bawazeer, M., Weicheng, D., Meghwar, G., & Xu, J. (2020) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre51194.2020.9233281 · Cited by 2
Hao, Y., Costa, L. F., Shu, L., Puczko, K., & Yang, D. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3617768 · Cited by 4
A Matrix-Type Back-to-Back Three-Phase Isolated AC–AC Converter
Wang, H., Yan, X. W., Zhou, F., Zhou, M., Xie, S., Su, M., & Huang, X. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3658688 · Cited by 2
“Besides, the bulky energy storage elements such as the DC-link electrolytic capacitors for energy buffering, lead to reduced power density and reliability [13], [14], [15].”
Trends in Isolated Power Converters Using High‐Frequency Transformers
Takeshita, T., Kitagawa, W., & Budo, K. (2026) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.70259 · Cited by 2
“The control system to realize these controls has been proposed [68].”
InfluentialMaster-slave control schemes for microgrids: A critical review
Ismail, A. A. A., Mbungu, N. T., Elnady, A., Bansal, R. C., Abo-Khalil, A. G., Hamid, A.-K., Bashir, S. B., Joy, E. R., & Alyammahi, A. K. S. O. (2026) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2026.117065 · Cited by 2
Itoh, J., Aoyagi, K., Kusaka, K., & Adachi, M. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507556 · Cited by 2
Yang, D., Chen, S., Zhang, X., Yang, L., Liu, J., & Shao, D. (2021) · IET Power Electronics · doi:10.1049/pel2.12082 · Cited by 2
“These advantages make CHB well-suited for medium- and high-voltage applications such as active power filters [2], solid-state transformers [3], static synchronous compensators [4], and photovoltaic inverters [5], among others.”
BackgroundA Three-Stage Power Electronic Transformer With Time-Sharing H-Bridges
Li, H., Zhang, C., Li, H., Mo, X., & Wei, P. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479015 · Cited by 2
Sha, D., & Xu, G. (2018) · CPSS power electronics series · doi:10.1007/978-981-13-0259-6_1 · Cited by 2
A Multiple-AC-Ports Power Electronic Transformer
Kong, X., Fan, X., Zhou, J., Shi, G., Zang, J., Wang, J., Cai, X., & Zhang, J. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9807011 · Cited by 2
Non-linear Controllers for Power Quality Improvement using Solid State Transformers in smart grids
Paraiso, G. M., Pinto, S. F., Javadi, S., & Silva, J. F. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968825 · Cited by 2
Saha, J., Pal, D., & Panda, S. K. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567505 · Cited by 2
Kim, D.-H., Han, B.-M., & Lee, J. (2016) · Energies · doi:10.3390/en9090668 · Cited by 2
Yu, C., Wang, Y., & Li, H. (2016) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2016.7779847 · Cited by 2
Self-citationLuo, C., Luo, D., Huang, S., Wu, G., Zhu, H., & He, Q. (2018) · Energies · doi:10.3390/en12010051 · Cited by 2
Liu, Y., He, J., Ge, B., Xue, Y. S., & Bayhan, S. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8592919 · Cited by 2
The Impedance-Based Stability Analysis of the Single-Phase Solid State Transformer
Wang, R., Sun, Q., Zhang, X., & Du, Y. (2018) · Chinese Automation Congress · doi:10.1109/cac.2018.8623288 · Cited by 2
“In the end, the inverter changes from the 400V dc voltage to the 220V ac voltage [10].”
BackgroundModified Carriers Pulse Width Modulation for Cascaded H-bridge Inverters
Korhonen, J., Järvisalo, H., Nykyri, M., Silventoinen, P., Giewont, W., Isaksson, D., & Hannonen, J. (2020) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie45063.2020.9152561 · Cited by 3
“This has led to the concept of solid state transformers, where CHB is a typical topology [9], [10].”
BackgroundHatatah, M., & Grainger, B. M. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236067 · Cited by 2
“Relevant research focuses on the voltage unbalance of the dc-link voltage of different H-bridge topologies [6]-[7].”
BackgroundFlexible control for power‐sharing in the CHB‐based SST under voltage unbalance conditions
Babaei, M., & Ghandehari, R. (2021) · IET Power Electronics · doi:10.1049/pel2.12160 · Cited by 3
“Cascaded H-bridge (CHB) converters and modular multilevel converters (MMC) are generally used for the high-voltage side of the SSTs [9, 10].”
InfluentialTransformer Cascaded 27-Level Multilevel Inverter for Medium-/High-Voltage PV System Integration
Molli, K., Raj, P. A. D. V., & Sudhakaran, M. (2023) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-023-00606-9 · Cited by 2
Ju, J., Choi, D.-H., & Lee, J.-S. (2023) · Energies · doi:10.3390/en16166095 · Cited by 2
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2023) · doi:10.36227/techrxiv.24272290 · Cited by 2
Kadri, A., Ebrahimi, R., & Pouresmaeil, E. (2022) · IET Renewable Power Generation · doi:10.1049/rpg2.12426 · Cited by 1
Min, G., & Xu, Y. (2023) · Energies · doi:10.3390/en16114298 · Cited by 1
Du, L., Zhao, T., Sun, Z., Feng, Z., & Lin, S. (2023) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec58067.2023.10166629 · Cited by 1
Mannen, T. (2024) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera62673.2024.10815268 · Cited by 1
Extreme Fast Charging Using Solid State Transformer
Etaveni, M., & Nukala, N. V. S. B. (2025) · Communications in computer and information science · doi:10.1007/978-3-032-00983-8_25 · Cited by 1
Medium Voltage Conversion Systems with Integrated Galvanic Isolation for Hybrid Photovoltaic Plants
Nguyen, D.-H., Martin, J., Gaillard, A., & Tran, Q. T. (2026) · Solar · doi:10.3390/solar6030018 · Cited by 1
“This configuration has already been investigated in the literature, mainly for LVDC/MVAC conversion, and has recently become a popular topology for MVDC/MVAC conversion in renewable energy applications [36,64–66].”
Yang, B., Zhao, H., Li, J., Zeng, G., & Zhao, J. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216170 · Cited by 1
Haghgooei, P., Khaburi, D. A., Khosravi, M., Heshmatian, S., Rodríguez, J., & Garcia, C. F. (2019) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede.2019.8753297 · Cited by 1
Voltage and Current Loop Controlled Three-stage, Three-port Solid State Transformer
Hadi, A. A., & Challoo, R. (2020) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--35491 · Cited by 1
Novel multi‐level inverters with flyback high frequency link
Guan, Y., Li, L., & Zhang, J. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0041 · Cited by 1
Hybrid Microgrid Based on Solid State Transformer
Nardoto, A. F., Corte, A. L., Santana, N. H. B., Amorim, A. E. A., Encarnação, L. F., & Santos, W. M. D. (2021) · IEEE URUCON · doi:10.1109/urucon53396.2021.9647193 · Cited by 1
Nonlinear Control Strategy of MMC Solid State Transformer under Unbalanced Network Conditions
Cheng, Q., Wen-qian, F., Miaozhen, Z., & Cheng, Y. (2021) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre52634.2021.9635277 · Cited by 1
Active Power Control of Grid Integrated Multiple Rooftop PV Plant with Power Quality Enhancement
Singh, Y., Singh, B., & Mishra, S. (2021) · International Conference on Computing, Communication and Automation · doi:10.1109/iccca52192.2021.9666432 · Cited by 1
“The proposed voltage-mode SMC is utilized in a master DG unit, while the current-mode SMC is utilized for slave units, in microgrid [9].”
MethodDecentralized Control Strategies in Grid-Connected Mode
Sun, Y., Hou, X., Lu, J., Liu, Z., Su, M., & Guerrero, J. M. (2021) · Power systems · doi:10.1007/978-3-030-91511-7_11 · Cited by 1
Control Strategy of Delta-Connected Solid State Transformer Under Unbalanced Grid Voltage
Ouyang, S. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773558 · Cited by 1
Nagano, T., Nishizawa, K., Maharjan, L., Tajyuta, T., & Maruyama, K. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9807172 · Cited by 1
Upreti, S., Yadav, S. K., Singh, B., & Kumar, N. (2023) · IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT) · doi:10.1109/globconht56829.2023.10087497 · Cited by 1
“The work done in [11], proposes a method to handle power imbalance issue for CHBs.”
MethodA H-Bridge-Multiplexing-Based Novel Power Electronic Transformer
Hou, B., Li, Y., Yu, Z.-Y., & Teng, Y. (2023) · Electronics · doi:10.3390/electronics13010022 · Cited by 1
Systematic approach to improve performance of asymmetrical 21‐level inverter with fewer components
Das, M. K., Mahish, P., Buduma, P., & Mishra, S. (2024) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.4229 · Cited by 1
Improved DC Link Voltage Balancing in an MV-Compliant Solid-State Transformer
Burugula, V., Nations, M., Sharma, S., Dhiman, S., Aljumah, O., Bhattacharya, S., & Prabowo, Y. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861784 · Cited by 2
Control strategies and applications of three-phase direct matrix converters
Zhang, J. (2018) · UTS ePRESS (University of Technology Sydney) · Cited by 1
Model Predictive Voltage Control applied to a Nested NPC to micro-grid applications
Norambuena, M., Garcia, C. F., & Rodríguez, J. (2018) · VBN Forskningsportal (Aalborg Universitet)
Li, J., Gong, C., & Chen, J. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9368173
“Individual voltage balancing control is realized by fundamental component injection[9-13], based on fundamental component injection balancing method, a cascaded rectifier voltage balancing method with mixed injection of offset and fundamental components is proposed to improve voltage balancing performance in this pape…”
MethodReactive Current Control Strategy of CHB-DSTATCOM Based on Unit Vector
Chen, J., Yang, D., Xu, S., & Chen, S. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/714/4/042038
“Therefore, it has become one of the most extensive multi-level topologies in power electronic transformers [2], photovoltaic grid-connected systems [3] and wind turbine generator system [4].”
BackgroundResearch on Optimal Control Strategy for Dual Active Bridge Converter with Phase Shift Control
Wang, P., Chen, X., Tong, C., Jia, P., & Wen, C. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479040
Korhonen, J., Jäppinen, J., Tolvanen, J., & Silventoinen, P. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570505
Liu, J., Gong, R., & Zhang, Y. (2022) · Journal of Power Electronics · doi:10.1007/s43236-022-00553-4
Integration Battery Energy Storage Using T- Type Solid State Transformer Based Multilevel InverterPreprint
Molli, K., & P, A. D. V. R. (2023) · Research Square · doi:10.21203/rs.3.rs-2709187/v1
Solid-State Transformer Enabled DCMG Architecture with Distributed Energy Management
Shitole, A. B., Khadkikar, V., Shaaban, M. F., Beig, A. R., & Zeineldin, H. H. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080131
“In addition, the SST also supports various ancillary services similar to FACT’s devices like independent voltage, current and power flow controllability [7], [8].”
Background2016 Index IEEE Transactions on Power Electronics Vol. 31
(2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3272431
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2023) · doi:10.36227/techrxiv.24272290.v1
Design and Modeling of Smart Intellegent Converters in Super Smart Grids
Raghavendra, R., Yadav, S., & Savita, S. (2023) · International Conference on Power Energy, Environment and Intelligent Control (PEEIC) · doi:10.1109/peeic59336.2023.10450287
Dedeoğlu, S. (2024) · Gazi Üniversitesi Fen Bilimleri Dergisi Part C Tasarım ve Teknoloji · doi:10.29109/gujsc.1434904
Vehicle electrification and renewables in modern power grids
Tavares, B., Rodrigues, J., Soares, F. J., Moreira, C., & Lopes, J. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13969-7.00008-4
Hou, N. (2024) · Synthesis lectures on power electronics · doi:10.1007/978-3-031-72963-8_1
Xiao, Z., Guo, S., Qu, Q., Chen, C., Xiang, X. J., & Li, W. (2024) · CPSS & IEEE International Symposium on Energy Storage and Conversion (ISESC) · doi:10.1109/isesc63657.2024.10785505
“[14], would increase the number of controllers and sensors and increase the burden on the main controller.”
Multilevel Converter-Based Charging Station for A Fleet of Electric Transit Buses
Wanjari, N. V., Tak, N., & Chattopadhyay, S. K. (2024) · IEEE Industrial Electronics and Applications Conference (IEACon) · doi:10.1109/ieacon61321.2024.10797446
“This approach minimizes the overall system's size and mitigates the limitations associated with two-level topologies [8], [9].”
Xu, L., Zhang, X., Zhao, W., Xu, J., & Zhuang, J. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3634170
Unruh, R., Böcker, J., & Schafmeister, F. (2025) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecce-europe62795.2025.11238538
Liu, D., Han, H. C., Shi, G., Ou, J., Su, M., & Sun, Y. (2025) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera66237.2025.11283781
“Connecting the PV panels end to end through H-bridge cascade of inverters to form a new energy grid-connected generate system [4] with a higher voltage level is another effective networking form for the new power system to consume distributed energy [5-6].”
Non-Isolated and Isolated Hybrid PET with Extended Vector Capability
Li, M., Meng, L., Lv, X. Q., Nie, J., & Shu, Z. (2025) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee67631.2025.11308946
“However, the power transfer stage is more, and the cost is high, which reduces the system efficiency [5], [6].”
Medium-Voltage Single-Stage Solid-State Transformer Based Fast Charger for Electric Vehicles
Liu, J., Wang, X., Chen, T., Xu, H., Xu, W., & Loo, K. H. (2025) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific63742.2025.11345055
“The number of power switches that work in high switching frequency can be reduced to improve efficiency [12]−[15].”
Dynamic phase shift-controlled SST-MLI for grid-connected battery storage
Molli, K., Hemachander, A., & Raj, P. A. D. V. (2026) · International Journal of Ambient Energy · doi:10.1080/01430750.2026.2630007
A Novel THI-PWM with Sorting Method for Grid-Connected CHB PV Inverter
Maheswari, G., Sharma, K. M., & Prabhakaran, P. (2026) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-026-01155-7
Data-Driven Adaptive Tracking Control for Nonlinear Dual-Active-Bridge Systems
Wang, Y., Song, H., Yang, Z. L., & Zhang, X. (2026) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls71227.2026.11610575
“DC transformers based on DC–DC converters constitute the core control equipment in DC distribution networks [1][2].”
Self-citationLiu, X., Yang, X., & Luo, W. (2026) · Scientific Reports · doi:10.1038/s41598-026-69330-8
DESIGN OF A NOVEL ASYMMETRIC TWENTY-ONE LEVEL INVERTER TOPOLOGY
YALÇİN, M. (2025) · Yildiz Technical University - AVESIS
Metadata
- Authors
- Wang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S.
- Affiliations
- Harbin Institute of Technology (CN)
- Toronto Metropolitan University (CA)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-04
- Volume
- 31
- Issue
- 4
- Pages
- 3289-3301
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2176835823
- Cited by
- 285
- References
- 26
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 20 · 2023: 27 · 2022: 33 · 2021: 33 · 2020: 39 · 2019: 38 · 2018: 31 · 2017: 30 · 2016: 15
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (51247009)
- Shenzhen Science and Technology Plan Project (JCYJ20140417172417127)
- China Academy of Space Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, cascaded H-bridge inverter, power balance control, master-slave control, dual active bridge converter, DC-link voltage balancing, microgrids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.