Power and Voltage Balance Control of a Novel Three-Phase Solid-State Transformer Using Multilevel Cascaded H-Bridge Inverters for Microgrid Applications
The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Abstract
This paper presents a new application of power and voltage balance control schemes for the cascaded H-bridge multilevel inverter (CHMI)-based solid-state transformer (SST) topology. To reduce load on the controller and simplify modulation algorithm, a master-slave control (MSC) strategy is designed for the dual active bridge (DAB) stage. The master controller executes all control and modulation calculations, and the slave controllers manage only device switching and protection. Due to the inherent power and dc-link voltage unbalance in cascaded H-bridge-based SST, this paper presents a compensation strategy based on three-phase dq decoupled current controller. An optimum zero-sequence component is injected in the modulation scheme so that the three-phase grid currents are balanced. Furthermore, to tightly regulate the output voltage of all the DAB modules to target value, a dynamic reference voltage method is also implemented. With this proposed control method, the three-phase grid currents and dc-link voltage in each module can be simultaneously balanced. Finally, simulation and experimental results are presented to validate the performance of the controller and its application to microgrid SST.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“In contrast, the SST is an intelligent power electronics system with capabilities such as managing power flow, providing power quality improvement, and allowing easy connection of the distribution resources [1]–[5].”
BackgroundSelf-citationA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Research on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 5×
“This paper extends some of the control methods developed previously [20]–[22] for different applications and validates the concept by means of numerical simulations, and extensive experimental validation carried out on a 10-kV·A laboratory prototype.”
BackgroundMethodInfluentialMaharjan, L., Inoue, S., & Akagi, H. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002180 · Cited by 310
Phase-Shifted Carrier PWM Technique for General Cascaded Inverters
Naderi, R., & Rahmati, A. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921186 · Cited by 301
Maharjan, L., Yamagishi, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059045 · Cited by 278
Liu, J., Cheng, K. W. E., & Ye, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2291514 · Cited by 277 · cited 1×
“Different topologies other than DAB dc–dc converter to boost the PV source voltage are also proposed for SST in [23] and [24] but the concept is based on transformerless SST where there is no isolation transformer between input and output.”
Method
Cited by
Items 101–200 of 289
Modeling and simulation of a MMC-based solid-state transformer
Adabi, M. E., Martínez-Velasco, J. A., & Alepuz, S. (2017) · Electrical Engineering · doi:10.1007/s00202-017-0510-x · Cited by 19
Islam, M. R., Hasan, M. M., Badal, F. R., Das, S. K., & Ghosh, S. K. (2020) · IEEE Access · doi:10.1109/access.2020.2986213 · Cited by 16
“An inverter with transformer consists of galvanic isolation that acts as voltage boosters which provides the galvanic isolation safety during the operation of the MG [12], [13].”
BackgroundA novel multi-port solid state transformer enabled isolated hybrid microgrid architecture
Nair, A. C., & Fernandes, B. G. (2017) · IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2017.8216113 · Cited by 15
Research on Control Strategy of Solid State Transformer Based on Improved MPC Method
Ding, C., Zhang, H., Chen, Y.-W., & Pu, G. (2023) · IEEE Access · doi:10.1109/access.2023.3240310 · Cited by 13
“The modular cascade topology in [6] has the limitation of voltage and power imbalance between modules, which can be controlled by the voltage and power equalization strategy, but it will greatly increase the complexity of the control system.”
BackgroundWang, C., Wang, X., Dong, Z., & Gu, C. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3039939 · Cited by 15
“Some similar balance methods were proposed in [19]–[22].”
MethodNOC-Based Multiple Low-Order Harmonic Currents Suppression Method
Lin, Z., He, L., Zhou, H., Zhang, J., & Xiong, Z. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3196918 · Cited by 15
“The power decoupling-based APF can suppress current harmonics while keeping the bus voltage stable, but the bulk passive components’ employment and corresponding loss and cost reduce its competitiveness [10], [11], [20], [21], [22], [23], [24], [25].”
BackgroundMethodAnalysis of Holdup Time for DC Grid-Forming Isolated Active Front-End Converters
Carvalho, E. L., Blinov, A., Chub, A., & Vinnikov, D. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9969075 · Cited by 15
“The advantage of this approach is related to the simplicity, as very-known and consolidated technologies could be used, including fullbridge [15] and neutral point clamped [16].”
Control of single-stage AC-AC solid state transformer for power exchange between grids
Liu, Y., Wang, W., Liu, Y., Abu‐Rub, H., & Li, Y. (2016) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2016.7603708 · Cited by 16
Cascaded multilevel converters in recent research and applications
Malinowski, M. (2017) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.1515/bpasts-2017-0062 · Cited by 17
Control Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
Ouyang, S., Liu, J., Chen, X., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2885562 · Cited by 15
Modified H-bridge multilevel inverter for Photovoltaic micro-grid systems
Biswas, M. M., Podder, S., & Khan, M. Z. R. (2016) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2016.7853935 · Cited by 15
“I. INTRODUCTION At the present time, the application of micro-grid connected PV systems is broadly preferable compared to standalone PV systems [1-3].”
BackgroundLi, J., Chen, J., Gong, C., & He, Q. S. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3244543 · Cited by 14
The hierarchical energy management control for residential energy harvesting system
Zhao, S., Zhang, Y., Moquin, S. J., & Mantooth, H. A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855501 · Cited by 14
“[10] L.”
MethodYang, D., Yin, L., Xu, S., & Wu, N. (2018) · Energies · doi:10.3390/en11092435 · Cited by 14
Sharma, B., Pankaj, P. K., Terriche, Y., Saim, A., Shrestha, A., Su, C., & Guerrero, J. M. (2023) · IEEE Access · doi:10.1109/access.2023.3250219 · Cited by 14
A New Topology of Multilevel Inverter with Reduced Part Count
Vijayaraja, L., Kumar, S. G., & Rivera, M. E. (2018) · IEEE International Conference on Automatica · doi:10.1109/ica-acca.2018.8609742 · Cited by 14
“compensation, Variable speed drives, High voltage DC and High voltage AC transmission lines, power factor corrector circuits, Back to back frequency link systems and in renewable energy systems [8] – [13].”
BackgroundRahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3137720 · Cited by 13
Li, H., Wang, Y., & Yu, C. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7794142 · Cited by 13
Self-citationZhao, T., & Chen, D. (2020) · IEEE Access · doi:10.1109/access.2020.3028122 · Cited by 14
“Several control strategies have been proposed in [10]–[12], [18] for CDBCHB PV inverter, which can ensure all modules to transmit the same active power, but these methods only consider the scenario that phase A, B, and C have the same number of modules.”
MethodHou, N., Li, Y., Quan, Z., Li, Y., & Zhou, A. F. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3085863 · Cited by 13
Song, J., Zhang, W., Liang, H., Jiang, J., & Yu, W. (2018) · Energies · doi:10.3390/en11010171 · Cited by 13
Solid-State Transformers: A Review—Part II: Modularity and Applications
Predescu, D.-M., & Rosu, S. G. (2025) · Technologies · doi:10.3390/technologies13020050 · Cited by 15
“In contrast, phase-modular configurations require the control of multiple converters and the balancing of their voltages and loadings [19,153,154].”
Transformer-less based solid state transformer for intelligent power management
Al-Hafri, A., Ali, H., Ghias, A., & Nasir, Q. (2016) · International Conference on Electronic Devices, Systems and Applications · doi:10.1109/icedsa.2016.7818507 · Cited by 10
Design and implementation of a PI-PBC to manage bidirectional power flow in the DAB of an SST
López-Rodríguez, K., Gil-González, W., & Mejía, A. E. (2022) · Results in Engineering · doi:10.1016/j.rineng.2022.100437 · Cited by 13
Wang, R., Sun, Q., Cheng, Q., & Ma, D. (2018) · Energies · doi:10.3390/en11092250 · Cited by 12
“Finally, the back-end side DC-AC converter produces an AC voltage to integrate an AC load, and the back-end side DC-DC co verter produces a DC voltage to integrate a DC load [29].”
BackgroundFalehi, A. D. (2020) · Electrical Engineering · doi:10.1007/s00202-020-00983-y · Cited by 12
Li, Y., Sun, Q., Wang, D., & Lin, S. (2019) · Energies · doi:10.3390/en12030517 · Cited by 12
Sensorless Voltage-Balanced Cascaded H-Bridge Rectifier Through Submodule Parallelization
Zhang, R., Wang, S., Ma, J., Wang, P., Qin, K., Li, J., & Liu, T. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3377277 · Cited by 11
“The software-based capacitor voltage balance methods have been widely applied in the industry due to the advantages of favorable balance performance, stable control ability, and easy implementation [7], [8], [9], [10], [11].”
BackgroundMethodZhao, T., Feng, Z., Wang, M., Wu, M., & Zhang, X. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3234304 · Cited by 11
“Compared with the centralized inverters connected to medium-voltage grid through line-frequency (LF) transformer [6], [7], [8], the advantages of three-phase PV solidstate transformer (SST) based on cascaded H-bridge (CHB) topology applied to large-scale PV power plants are more prominent, such as modular structure, l…”
BackgroundZhao, T., Sun, Z., Feng, Z., Wang, M., Wu, M., & Zhang, X. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3266613 · Cited by 11
“Since three-phase common dc-bus isolated CHB inverter has the advantages of no intermodule and interphase power imbalance problems, it is studied in this article due to simple control [8], [12], [14].”
BackgroundMa, X., Yang, X., Zhang, F., Huang, L., Li, Z., & Song, H. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930736 · Cited by 12
Rodrigues, W. A., de Oliveira, T. R., Morais, L. M. F., & Rosa, A. H. R. (2018) · Energies · doi:10.3390/en11071802 · Cited by 13
Single-Phase Switched-Capacitor Integrated-Boost Five-level Inverter
Khan, M. N. H., Siwakoti, Y. P., Li, L., & Forouzesh, M. (2018) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tenconspring.2018.8692066 · Cited by 11
Haritha, G., Sundaramoorthy, K., & Sankar, A. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2963277 · Cited by 11
“Different power management schemes are also incorporated by modulating the three-phase inverter controller to achieve power flow schemes [27], [28].”
BackgroundA triple port active bridge converter based multi-fed power electronic transformer
Jakka, V. N. S. R., & Shukla, A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854797 · Cited by 11
A fault tolerant control approach for a three-stage cascaded multilevel solid state transformer
Gorla, N. B. Y., Kolluri, S., Chauhan, P. J., & Panda, S. K. (2017) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2017.8013310 · Cited by 11
“A promising modular SST architecture that is being studied more often in the recent past is a three-stage cascaded multilevel SST [5]–[7].”
BackgroundMethodOuyang, S., Liu, J., & Chen, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3075085 · Cited by 12
“Other than [18], the mainstream control of SST+LVdc chooses just setting ZS component to zero [19]–[22].”
BackgroundLewicki, A., & Morawiec, M. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5886 · Cited by 10
“The vast majority of papers show the methods for balancing the DC-link voltages [23], [25], [46], [47], [53], [54].”
BackgroundSingle-Phase Operating Modes for DC–DC Three-Phase Dual-Active-Bridge With YΔ Transformer
Cúnico, L. M., & Kirsten, A. L. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3142686 · Cited by 10
Prabaharan, N., Saravanan, S., Jerin, A. R. A., & Palanisamy, K. (2017) · InTech eBooks · doi:10.5772/67863 · Cited by 10
Jeyapradha, R. B., & Rajini, V. (2018) · ISA Transactions · doi:10.1016/j.isatra.2018.09.012 · Cited by 11
A Control Scheme Based on Lyapunov Function for Cascaded H-Bridge Multilevel Active Rectifiers
Jean-Pierre, G., Altın, N., Shafei, A. E., & Nasiri, A. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124234 · Cited by 9
“In [23], a compensation controller based on three-phase dq decoupled strategy was presented to address the unbalanced DC voltage and power of the converter.”
MethodSmith, C., & Haque, M. E. (2020) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias44978.2020.9334924 · Cited by 9
“There is good scope for the introduction of a master-slave SST arrangement in microgrids to handle grid conditions from a central point, as well as introduce load balancing on connected storage devices [16] [17] [18].”
BackgroundNew configurations of power converters for grid interconnection systems
Rivera, M. E., Toledo, S., Nasir, U., Costabeber, A., & Wheeler, P. W. (2016) · IEEE International Conference on Automatica · doi:10.1109/ica-acca.2016.7778521 · Cited by 9
“ers such as the three-level neutral point clamped (3L-NPC) converters [21]-[23] and cascade H-Bridge topologies [24].”
BackgroundAmended THD with modified phase-shifted PWM for micro-grid connected multilevel inverter
Biswas, M. M., & Khan, M. Z. R. (2017) · IEEE Power and Energy Conference at Illinois (PECI) · doi:10.1109/peci.2017.7935734 · Cited by 9
Katir, H., Abouloifa, A., Lachkar, I., Noussi, K., Giri, F., & Guerrero, J. M. (2020) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2020.12.2095 · Cited by 9
“Whereas, using a boost converter offers the opportunity to minimize the number of the PV modules (Wang et al., 2016).”
MethodAdvanced modeling of solid state transformer
Adabi, M. E. (2018) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-113997 · Cited by 10
ILYUSHIN, P. V., Volnyi, V., & Suslov, K. (2025) · Applied Sciences · doi:10.3390/app152010970 · Cited by 9
Three-Level Isolated Direct AC–AC Converter and its Closed-Loop Control Strategy
Wu, F., Wei, Y., & Su, J. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3238399 · Cited by 9
“The first one is the dual active bridge (DAB) dc–dc converter-based three-stage ac–dc–ac structures [8], [9], [10].”
BackgroundBabkrani, Y., Naddami, A., & Mohamed, H. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-11928-7_5 · Cited by 8
Esenboğa, B., & Demirdelen, T. (2022) · Sustainability · doi:10.3390/su15010032 · Cited by 8
Xiao, X., Zhang, M., Yang, R. H., Chen, X., & Zheng, Z. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123629 · Cited by 8
Li, L., Sun, Y., Hou, X., Su, M., Zhang, X., Wang, P., & Guerrero, J. M. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.0990 · Cited by 8
Transient Current Constraint of DAB Converter Based on Model Predictive Control
Xiao, Z., Lei, W., Gao, G., Cui, Y., Kang, Q., & Wang, M. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367975 · Cited by 8
HRES power generation: the power injection control and the grid synchronization cases
(2019) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v9i2.9050.g7634 · Cited by 8
“This is a good advantage compared to similar methods of only current control [25], [26] or voltage control [27].”
MethodTanguturi, J., & Keerthipati, S. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3544210 · Cited by 7
“The present trend of using solid state transformers (SST) for power electronics has resulted in various MLI topologies for PV applications to avoid power imbalance [13], [14].”
Modelling, Design and Control of Cascaded H-Bridge Single Phase Rectifier
Kadandani, N. B., Ethni, S., Dahidah, M., & Khalfalla, H. (2019) · International Renewable Energy Congress · doi:10.1109/irec.2019.8754627 · Cited by 7
Coupled-DC Module-Based Photovoltaic System With Power Mismatch-Tolerated Modulation
Wang, C., He, P., He, L., Li, L., & Xue, Y. S. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3131182 · Cited by 7
“a medium- or high-voltage (MV/HV) distribution grid are growing in a rapid way [1]–[6].”
BackgroundTwo-Type Single-Stage Isolated Modular Multilevel Cascaded Converter (I-M2C2) Topologies
Liu, C., Wen, L., Yang, D., Ying, H., Liu, C., & Zhang, H. (2019) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2019.00002 · Cited by 7
Modular Medium Voltage AC to Low Voltage DC Converter for Extreme Fast Charging ApplicationsPreprint
Awal, M. A., Husain, I., Bipu, M. R. H., Bipu, M. R. H., Montes, O. A., Teng, F., Feng, H., Khan, M. A., & Lukic, S. M. (2020) · arXiv (Cornell University) · doi:10.13140/rg.2.2.26685.90082 · Cited by 7
Efficiency Improvement of DAB Converters with Enhanced Inductor Current Classification
Xiao, Z., Zhang, L., He, Z., & Tang, Y. K. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362300 · Cited by 6
“…features galvanic isolation, soft switching capability, wide voltage gain range, high power density, and bidirectional power flow ability [1]-[5], and has been widely applied to energy storage systems [4], micro-grids [5]-[7], automation application [8], [9], and solid-state transformer [10]-[12].”
BackgroundLi, H., Wang, Y., & Yu, C. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793369 · Cited by 6
Self-citationTang, X., Zhang, J., Liu, Z., & Zhang, M. (2017) · Energies · doi:10.3390/en10050725 · Cited by 6
Single-Phase Reactive Power Compensation Control for STATCOMs via Unknown System Dynamics Estimation
Guo, C., Zhong, L., Zhao, J., & Gao, G. (2020) · Mathematical Problems in Engineering · doi:10.1155/2020/8394513 · Cited by 6
Design of Three Phase Solid State Transformer Deployed within Multi-Stage Power Switching Converters
Tahir, U., Abbas, G., Glãvan, D. O., Bălaş, V. E., Farooq, U., Bǎlaş, M. M., Raza, A., Asad, M. U., & Gu, J. J. (2019) · Applied Sciences · doi:10.3390/app9173545 · Cited by 7
Unruh, R., Lange, J. H., Schafmeister, F., & Böcker, J. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570542 · Cited by 8
Hybrid bidirectional DC/DC converter: Mutual control and stability analysis
Liu, H., Cui, S., Zhang, H., Hu, Y., Xue, Y., & Liu, C. (2022) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2021.00260 · Cited by 8
Alam, K. S., Tria, L. A. R., Zhang, D., Xiao, D., & Rahman, M. F. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056068 · Cited by 6
Self-citationAlshawish, A. M., Eshtaiwi, S. M. M., Ahmadi, R., & Saadatmand, S. (2020) · IEEE Power and Energy Conference at Illinois (PECI) · doi:10.1109/peci48348.2020.9064642 · Cited by 6
“The proposed SST topology is derived by introducing Z-source circuitry into a well-known three-stage cascaded multilevel SST topology [6]-[7].”
MethodZaid, M. M., & Ro, J. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1389 · Cited by 6
Suryawanshi, A. R., & Chopade, N. B. (2019) · International Conference on Innovative Trends and Advances in Engineering and Technology (ICITAET) · doi:10.1109/icitaet47105.2019.9170239 · Cited by 6
“This statement can be expressed as [1, 6, 25, 29, 30].”
López-Rodríguez, K., Mejía, A. E., Piedrahita-Echavarria, E. Y., & Gil-González, W. (2020) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg48541.2020.9244412 · Cited by 6
“Contrary to this methodology, a master-slave control scheme is proposed in [17], where one converter receives signals at the”
MethodSolid state transformer control aspects for various smart grid scenarios
Gorla, N. B. Y., Kolluri, S., & Panda, S. K. (2017) · 2017 IEEE Innovative Smart Grid Technologies - Asia (ISGT-Asia) · doi:10.1109/isgt-asia.2017.8378443 · Cited by 5
“The operation and basic control schemes of the threestage CMSST are discussed in [8]–[10] and are not discussed here again.”
BackgroundSingle-Phase AC/AC Multilevel H-Bridge Transformerless Converter with SST Functionalities
Campos, B. F. D. A., Camargo, R. S., Peña, E. J. B., & Encarnação, L. F. (2021) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng50821.2021.9501201 · Cited by 6
Bipu, M. R. H., Montes, O. A., Lukic, S. M., & Husain, I. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362709 · Cited by 5
“In traditional approach, the SST is controlled by the controller CCon where the AFEs control the voltage of MV DC buses and the DABs control the required power flow to maintain the voltage of the LV DC bus [8], [9].”
MethodNayak, G., & Dasgupta, A. (2024) · IEEE Access · doi:10.1109/access.2024.3376386 · Cited by 5
Power Balance Control Scheme for a Cascaded Matrix-Based Dual-Active-Bridge (CMB-DAB) Converter
Saha, J. (2022) · Springer theses · doi:10.1007/978-981-19-4902-9_5 · Cited by 5
Power Quality Improvement of the Distribution System using a Solid-State Transformer
Hossain, M. S., Rahman, M. A., Islam, M. R., Sutanto, D., & Muttaqi, K. M. (2022) · IEEE Industrial Electronics Society Annual On-Line Conference (ONCON) · doi:10.1109/oncon56984.2022.10126708 · Cited by 5
“The three-stage SST architecture based on the high-frequency magnetic link is shown as one of the most promising configurations for combining all the advantages aspects of SST into a single energy buffer unit [4].”
BackgroundMethodReducing neutral-point voltage fluctuation in NPC three-level active power filters
Qian, P., Ma, X., Liu, G., & Chen, Z. (2017) · Electrical Engineering · doi:10.1007/s00202-017-0538-y · Cited by 5
Haritha, G., Kumaravel, S., & Ashok, S. (2018) · 2018 2nd International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2018.8356290 · Cited by 5
Nie, J., Yuan, L., Gu, Q., Sun, J., & Zhao, Z. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507492 · Cited by 5
Rong, J., Ai, X., Li, Y., & Ren, D. (2019) · Applied Sciences · doi:10.3390/app9040727 · Cited by 5
Design and software implementation of solid state transformer
Hassan, R. F. (2018) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i3.16423 · Cited by 6
Research of SIC Solid State Transformer Model for Electric Vehicles Chargers Applications
Moradewicz, A. J., Miskiewicz, R. M., Parchomiuk, M., & Sak, T. (2019) · Progress in Applied Electrical Engineering (PAEE) · doi:10.1109/paee.2019.8788996 · Cited by 5
A Multilevel Solid-State Transformer-Based Grid-Connected Solar Photovoltaic Systems
Taghvaie, A., Haque, M. E., Saha, S., & Mahmud, M. A. (2021) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias48185.2021.9677143 · Cited by 5
Qiao, L., Shimizu, Y., & Hagiwara, M. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3204736 · Cited by 5
“Therefore, the line-frequency transformer is necessary to galvanically isolate the dc side from the ac side and to step-up the voltage of the PV array to the voltage level of the medium-voltage ac grid [17], [18], [19].”
BackgroundJean-Pierre, G., Altın, N., Shafei, A. E., & Nasiri, A. (2023) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2023.3239414 · Cited by 5
“In [25], a decoupled dq three-phase control strategy was studied to compensate for the unbalanced DC voltage and power of the converter.”
BackgroundHaghighat, M., Tafti, H. D., Gholipour, M., Niroomand, M., Townsend, C. D., Vazquez, N., Liang, G., Konstantinou, G. S., & Pou, J. (2024) · IEEE Access · doi:10.1109/access.2024.3496518 · Cited by 4
Level-phase-shifted pulse-width modulation for cascaded H-bridges
Korhonen, J., Järvisalo, H., Jäppinen, J., & Silventoinen, P. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968448 · Cited by 4
“Since, the application range has vastly increased with the applications like static synchronous compensator (STATCOM) and solid state transformers [2], [3], [4], [5].”
BackgroundGorla, N. B. Y., Saha, J., Chandra, R., & Panda, S. K. (2020) · IEEE PES Innovative Smart Grid Technologies Conference Europe · doi:10.1109/isgt-europe47291.2020.9248868 · Cited by 4
“According to [5]–[7], [11], [12], the major advantage with the VBC in stage-1 is that it reduces the control complexity in stage-2.”
BackgroundConcepts, Configurations, and Challenges of Solid-State Transformer: A Review
Solanki, J. B., & Chudasama, K. J. (2022) · Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering) · doi:10.2174/2352096515666220707120302 · Cited by 8
A Cascaded H-Bridge Multilevel Inverter with SOC Battery Balancing
Khalili, T., Raihani, A., Bouattane, O., & Ouajji, H. (2017) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2017.081245 · Cited by 4
Falehi, A. D. (2019) · Multidimensional Systems and Signal Processing · doi:10.1007/s11045-019-00669-0 · Cited by 4
A Multiport Three-stage Power Electronic Transformer
Ma, D.-J., Chen, W., & Shu, L. (2020) · Applied Power Electronics Conference · doi:10.1109/apec39645.2020.9124369 · Cited by 3
“Moreover, PETs can be used in the smart grid to realize energy management and AC/DC hybrid distribution [2], [3].”
A New Fault Tolerant SST Topology and Operation Strategy for Alleviating HVAC Grid Faults
Alshawish, A. M., Jafarishiadeh, S., Ghasemi, A., Shojaeighadikolaei, A., & Ahmadi, R. (2020) · IEEE Kansas Power and Energy Conference (KPEC) · doi:10.1109/kpec47870.2020.9167634 · Cited by 4
“The proposed SST topology is derived by introducing Z-source circuitry into a well-known three-stage cascaded multilevel SST topology [8]-[9].”
MethodYang, B., Wang, R., Xiao, F., Zhang, X., Jie, G., Gao, S., Wang, H., & Kang, W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3237721 · Cited by 4
“topology of a three-phase cascaded H-bridge inverter [2], [3], as shown in Fig.”
MethodSOLID STATE TRANSFORMER (SST) AND THE CHALLENGES OF THE FUTURE GRID
Kadandani, N. B., Hassan, S., & Abubakar, I. (2023) · FUDMA Journal of Sciences · doi:10.33003/fjs-2023-0703-1965 · Cited by 4
A DC-DC Converter-Based Single-Source Transformer-less Multilevel Inverter
Jahan, H. K., Shotorbani, A. M., Khosroshahi, A. E., Wang, L., Blaabjerg, F., Abapour, M., & Zare, K. (2019) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2019.8769709 · Cited by 4
Self-citationPower Electronic Transformer Based on Mixed-Frequency Modulation Strategy
Shu, L., Chen, W., & Zhang, C. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797164 · Cited by 5
Rahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070582 · Cited by 5
“Several research works have been reported in [9]–[12] to balance the power and the voltage of the dual-active bridge (DAB)-based dc-dc converter for the SST applications.”
Background
Metadata
- Authors
- Wang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S.
- Affiliations
- Harbin Institute of Technology (CN)
- Toronto Metropolitan University (CA)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-04
- Volume
- 31
- Issue
- 4
- Pages
- 3289-3301
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2176835823
- Cited by
- 285
- References
- 26
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 20 · 2023: 27 · 2022: 33 · 2021: 33 · 2020: 39 · 2019: 38 · 2018: 31 · 2017: 30 · 2016: 15
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (51247009)
- Shenzhen Science and Technology Plan Project (JCYJ20140417172417127)
- China Academy of Space Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, cascaded H-bridge inverter, power balance control, master-slave control, dual active bridge converter, DC-link voltage balancing, microgrids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.