Power and Voltage Balance Control of a Novel Three-Phase Solid-State Transformer Using Multilevel Cascaded H-Bridge Inverters for Microgrid Applications
The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.
Abstract
This paper presents a new application of power and voltage balance control schemes for the cascaded H-bridge multilevel inverter (CHMI)-based solid-state transformer (SST) topology. To reduce load on the controller and simplify modulation algorithm, a master-slave control (MSC) strategy is designed for the dual active bridge (DAB) stage. The master controller executes all control and modulation calculations, and the slave controllers manage only device switching and protection. Due to the inherent power and dc-link voltage unbalance in cascaded H-bridge-based SST, this paper presents a compensation strategy based on three-phase dq decoupled current controller. An optimum zero-sequence component is injected in the modulation scheme so that the three-phase grid currents are balanced. Furthermore, to tightly regulate the output voltage of all the DAB modules to target value, a dynamic reference voltage method is also implemented. With this proposed control method, the three-phase grid currents and dc-link voltage in each module can be simultaneously balanced. Finally, simulation and experimental results are presented to validate the performance of the controller and its application to microgrid SST.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“In contrast, the SST is an intelligent power electronics system with capabilities such as managing power flow, providing power quality improvement, and allowing easy connection of the distribution resources [1]–[5].”
BackgroundSelf-citationA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Research on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 5×
“This paper extends some of the control methods developed previously [20]–[22] for different applications and validates the concept by means of numerical simulations, and extensive experimental validation carried out on a 10-kV·A laboratory prototype.”
BackgroundMethodInfluentialMaharjan, L., Inoue, S., & Akagi, H. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002180 · Cited by 310
Phase-Shifted Carrier PWM Technique for General Cascaded Inverters
Naderi, R., & Rahmati, A. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921186 · Cited by 301
Maharjan, L., Yamagishi, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059045 · Cited by 278
Liu, J., Cheng, K. W. E., & Ye, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2291514 · Cited by 277 · cited 1×
“Different topologies other than DAB dc–dc converter to boost the PV source voltage are also proposed for SST in [23] and [24] but the concept is based on transformerless SST where there is no isolation transformer between input and output.”
Method
Cited by
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 473
“solid state transformers [36]–[39]), motor drives (which used in transportation/traction [40]–[47], marine propulsion [48]–[52], mine hoists [53], conveyors [54], [55]), industrial application”
BackgroundHybrid AC–DC Microgrid: Systematic Evaluation of Control Strategies
Gupta, A., Doolla, S., & Chatterjee, K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2727344 · Cited by 355
“Thus, SST based HMG can coordinate power exchange among existing neighboring ac and dc microgrid [62], [63] and provide ancillary services to the grid [59].”
BackgroundHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“The control strategies and balancing circuits are also required to prevent the problem in voltage and power balancing and that comes with drawbacks like complex systems in configuration and control scheme [17], [18].”
BackgroundPrabaharan, N., & Palanisamy, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.121 · Cited by 302
Rabiul Islam, M., Mahfuz-Ur-Rahman, A. M., Muttaqi, K. M., & Sutanto, D. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2878885 · Cited by 178
Choudhury, S., Bajaj, M., Dash, T., Kamel, S. M., & Jurado, F. (2021) · Energies · doi:10.3390/en14185773 · Cited by 179
Modeling Electronic Power Converters in Smart DC Microgrids—An Overview
Francés, A., Asensi, R., García, O., Prieto, R., & Uceda, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2707345 · Cited by 148
“DAB can be often found in microgrids designs associated with solid-state transformers [19], [20].”
BackgroundKala, P., & Arora, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.008 · Cited by 149
Ruiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 144
“Additionally, depending on the MV converter topology, NPC, CHB, and MMC, the first level should provide a balance of dc-link voltages capacitors [76]–[82].”
BackgroundLiu, T., Yang, X., Chen, W., Li, Y., Xuan, Y., Huang, L., & Hao, X. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2864657 · Cited by 144
A review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 130
Dynamic Control and Performance of a Dual-Active-Bridge DC–DC Converter
Takagi, K., & Fujita, H. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2773267 · Cited by 118
Shadfar, H., Pashakolaei, M. G., & Foroud, A. A. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12996 · Cited by 99
Sha, D., Xu, G., & Xu, Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696511 · Cited by 98
“CHB converter has also been widely used in EV motor drive [20], microgrid [32], and grid-tied PV system [33], [34].”
MethodElectric cars, ships, and their charging infrastructure – A comprehensive review
Mutarraf, M. U., Guan, Y., Xu, L., Su, C. L., Vásquez, J. C., & Guerrero, J. M. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2022.102177 · Cited by 114
Wai, R., Zhang, Q.-Q., & Wang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2831673 · Cited by 88
“System dominant root locus at ke ∈ [1, 50].”
BackgroundSelf-citationWang, Y., Li, Y., Cao, Y., Tan, Y., He, L., & Han, J. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.02.048 · Cited by 89
Self-citationHan, Y., Li, H., Xu, L. W., Zhao, X., & Guerrero, J. M. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2647958 · Cited by 81
“Compared to the conventional distributed power generation systems, a microgrid has enhanced control flexibilities to fulfill system reliability and power quality requirements, which can operate in either grid-connected or islanded mode [3]–[7].”
BackgroundMultiport Railway Power Conditioner and Its Management Control Strategy With Renewable Energy Access
Ma, F., Wang, X., Deng, L., Zhu, Z. Q., Xu, Q., & Xie, N. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899138 · Cited by 78
Nair, A. C., & Fernandes, B. G. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3038091 · Cited by 75
“The issue of power unbalance in SST is investigated in [24]– [26].”
BackgroundGorla, N. B. Y., Kolluri, S., Chai, M., & Panda, S. K. (2019) · IEEE transactions on power electronics · doi:10.1109/tpel.2018.2873201 · Cited by 48
“According to [35]–[39], the major advantage with the VBC in stage-1 is that it reduces the control complexity in stage-”
BackgroundMethodInfluentialLee, M., Yeh, C.-S., Yu, O., Kim, J., Choe, J.-M., & Lai, J. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2919200 · Cited by 57
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3118657 · Cited by 68
“power routing through each H-bridge, leading to unequal voltage stresses in the semiconductor devices and increased gridcurrent’s total harmonic distortion (THD) [13], [15].”
BackgroundMethodInfluentialAnalysis and Control of a Novel Modular-Based Energy Router for DC Microgrid Cluster
Tu, C., Xiao, F., Zheng, L. X., Guo, Q., & Shuai, Z. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2878004 · Cited by 67
“Compared with the classical SST [11], [12], MBER does not need extra dc/dc converters (ECs), and it can offer multiport for DCMG, so it is more suitable for DCMG cluster.”
BackgroundMethodYu, H., Niu, S., Shao, Z., & Jian, L. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107476 · Cited by 68
Overview of Recent Advanced Topologies for Transformerless Dual-Grounded Inverters
Guo, X., Zhang, H., Tang, W., Lu, Z., Hua, C., Siwakoti, Y. P., Malinowski, M., & Blaabjerg, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3170931 · Cited by 63
Hota, A., Jain, S., & Agarwal, V. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2688394 · Cited by 60
Ouyang, S., Liu, J., Yang, Y., Chen, X., Song, S., & Wu, H. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2922915 · Cited by 60
“balance the dc voltage among phases by zero-sequence voltage injection [21], [22] or negative-sequence current injection [23]”
BackgroundKrishnachaitanya, D., & Chitra, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3071375 · Cited by 61
Liu, Y., Liu, Y., Ge, B., & Abu‐Rub, H. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2679137 · Cited by 61
An Isolated Modular Multilevel Converter (I-M2C) Topology Based on High-Frequency Link (HFL) Concept
Liu, C., Liu, C., Cai, G., Ying, H., Zhang, Z., Shan, R., Pei, Z., & Song, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923355 · Cited by 61
Yi, Z., Sun, K., Liu, H., Cao, G., & Lu, S. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3094674 · Cited by 57
Review of Solid-State Transformer Applications on Electric Vehicle DC Ultra-Fast Charging Station
Valedsaravi, S., Aroudi, A. E., & Martinez-Salamero, L. (2022) · Energies · doi:10.3390/en15155602 · Cited by 60
Kersten, A., Theliander, O., Grunditz, E. A., Thiringer, T., & Bongiorno, M. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2921852 · Cited by 51
Sun, Q., Li, Y., Ma, D., Zhang, Y., & Qin, D. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3064418 · Cited by 51
Xiao, Q., Mu, Y., Jia, H., Jin, Y., Hou, K., Yu, X., Teodorescu, R., & Guerrero, J. M. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.116154 · Cited by 52
Lee, J.-S., Sim, H.-W., Kim, J.-Y., & Lee, K. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2772139 · Cited by 50
“There are several multilevel inverter topologies: the neutralpoint clamped topology [2], [4], [7], the flying capacitor topology [10], [11], the cascaded H-bridge (CHB) topology [3], [6], etc.”
BackgroundXiang, X., Zhang, X., Chaffey, G. P., & Green, T. C. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2735634 · Cited by 50
Inverter-based islanded microgrid: A review on technologies and control
Fani, B., Shahgholian, G., Alhelou, H. H., & Siano, P. (2022) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2022.100068 · Cited by 46
Tian, J., Mao, C., Wang, D., Nie, S., & Yang, Y. (2018) · IEEE transactions on power electronics · doi:10.1109/tpel.2018.2794558 · Cited by 33
Rahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2972507 · Cited by 50
“A solution to the grid interphase voltage unbalance problem and a harmonic analysis-based control strategy to remove grid current harmonics have been reported for an SST-driven distribution system in [18] and [19], respectively.”
BackgroundWang, C., Zhang, K., Xiong, J., Xue, Y. S., & Liu, W. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2842789 · Cited by 46
“Similarly, for SSTs [6]–[8], even though total active power is determined by the load, the power distribution among the modules is still adjustable thanks to a common dc link.”
BackgroundZhang, J., Li, L., Dorrell, D. G., Norambuena, M., & Rodríguez, J. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2874275 · Cited by 44
Power-Linked Predictive Control Strategy for Power Electronic Traction Transformer
Zhao, N., Liu, J., Ai, Y., Yang, J., Zhang, J., & You, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2952914 · Cited by 44
“Similar structures that use module-cascaded structure and high-frequency-link technology are also used in a solidstate transformer (SST) [5]–[7] or power electronic transformer (PET) [8]–[10] to realize power conversion.”
Song, W., Zhong, M., Luo, S., & Yang, S. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3006135 · Cited by 42
“In the locomotive PET application, the intermediate-stage dc–dc converter usually works under load fluctuation conditions [18], [19]; therefore, it is significant to improve its dynamic response.”
BackgroundZhao, T., Zhang, X., Wang, M., Mao, W., Ma, M., Wang, F., & Wang, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2988989 · Cited by 39
Lin, H., Lin, C., Xie, D., Acuna, P. F., & Liu, W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3324871 · Cited by 38
Ahmed, T. A., Mohamed, E. E. M., Youssef, A., Ibrahim, A. A., Saeed, M. S. R., & Ali, A. I. M. (2020) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2019.11.003 · Cited by 37
Feedforward Proportional Carrier-Based PWM for Cascaded H-Bridge PV Inverter
Huang, Q., & Huang, A. Q. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2817183 · Cited by 34
“In summary, all the conventional carrier-based PWM techniques need at least n dc voltage controllers for the individual dc voltage control [10]–[19], [22]–[29], [31]–[35], [49].”
BackgroundInfluentialDu, L., & He, J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2919386 · Cited by 34
A Simplified SVM-Based Fault-Tolerant Strategy for Cascaded H-Bridge Multilevel Converters
Lin, H., Zhu, L., Mehrabankhomartash, M., Saeedifard, M., & Shu, Z. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2987178 · Cited by 33
“In the technical literature, the CHMC has been investigated for motor drive [3], STATCOM [4], and solid-state transformer [5] applications.”
BackgroundAn Efficient Modulation Strategy for Cascaded Photovoltaic Systems Suffering From Module Mismatch
Wang, C., Zhang, K., Xiong, J., Xue, Y. S., & Liu, W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2756338 · Cited by 34
Qu, Z.-W., Yao, Y., Wang, Y.-J., Zhang, C.-J., Chong, Z., & Abu-siada, A. (2019) · IEEE Access · doi:10.1109/access.2019.2933414 · Cited by 23
Self-citationZhao, T., Zhang, X., Wang, M., Mao, W., Li, F., Wang, F., & Wang, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2964950 · Cited by 33
“Several different control strategies of cascaded modular PV SST are proposed in [7]–[9] and [13], but these methods are only applied to the scenarios where the number of modules in each phase, of a three-phase system, is the same.”
MethodZheng, L., Kandula, R., & Divan, D. (2021) · IEEE transactions on power electronics · doi:10.1109/tpel.2021.3085679 · Cited by 20
“In [19], the CHB has PI controllers for dc-link voltage balance and MV grid current control while common-duty-cycle control is used for the DAB.”
BackgroundMethodA Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems
Duman, T., Marti, S., Moonem, M. A., Kader, A. A., & Krishnaswami, H. (2017) · Energies · doi:10.3390/en10050698 · Cited by 31
A Rotational Control in Medium-Voltage Modular Solid-State Transformer-Based Converter System
Dong, D., Raju, R., Ganireddy, G., & Agamy, M. S. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2932958 · Cited by 31
Zheng, L., Kandula, R. P., Kandasamy, K., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3050115 · Cited by 28
Song, W., Zhong, M., Deng, Y., Yin, S., & Yu, B. (2022) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2022.3174800 · Cited by 28
A Decentralized Control for Cascaded Inverters in Grid-Connected Applications
Li, L., Sun, Y., Han, H., Shi, G., Su, M., & Zheng, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2945266 · Cited by 27
“Recently, they have been extended to distributed generation, such as acstacked photovoltaic (PV) generation, the energy storage system, and microgrids [3], [4].”
BackgroundLi, X., Cheng, L., He, L., Wang, C., & Zhu, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3138594 · Cited by 26
A review on multilevel inverter with reduced switch count
Vijayaraja, L., Kumar, S. G., & Rivera, M. E. (2016) · IEEE International Conference on Automatica · doi:10.1109/ica-acca.2016.7778467 · Cited by 26
“In [14], a dynamic reference voltage, optimum zero sequence injection and power balance control technique for three phase solid state transformer with Cascaded H-bridge multilevel inverter used in microgrid applications was proposed.”
MethodA Self-Synchronized Decentralized Control for Series-Connected H-Bridge Rectifiers
Hou, X., Sun, Y., Zhang, X., Zhang, G., Lu, J., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896150 · Cited by 26
“In practice, it is very common in solid-state transformers and traction applications [3]–[5].”
BackgroundZhang, X., Xu, Y., Siddique, A., Long, Y., & Xiao, X. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2946463 · Cited by 26
Sun, J., Sun, Q., Ma, D., & Wang, P. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0076 · Cited by 25
Low-Frequency Voltage Ripples Decoupling With Switched-Capacitor Conversion for an MMC-Based SST
Bu, Z., Teng, J., Sun, X., Pan, Y., & Pan, Y. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3121715 · Cited by 25
Xiao, Q., Mu, Y., Jia, H., Jin, Y., Yu, X., Teodorescu, R., & Guerrero, J. M. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.118140 · Cited by 26
Pan, Y., Teng, J., Yang, C., Bu, Z., Wang, B., Li, X., & Sun, X. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3239164 · Cited by 24
“drive and smart grid as it is modular highly, easy to expand and friendly for redundant operation [1], [2], [3].”
BackgroundSun, X., Teng, J., Bu, Z., Pan, Y., Zhao, W. M., & Li, X. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3065235 · Cited by 28
Switch fault detection and diagnosis in space vector modulated cascaded H-bridge multilevel inverter
Raj, N., Kale, T., Anjali Anand, K., Jagadanand, G., & George, S. (2018) · International Journal of Electronics · doi:10.1080/00207217.2018.1494327 · Cited by 23
Li, Y., Sun, Q., Qin, D., Cheng, K., & Li, Z. (2020) · IEEE Access · doi:10.1109/access.2020.2987075 · Cited by 24
“For the predigesting modulation algorithm, a master-slave control (MSC) strategy was scheduled for the cascaded dual active bridge (DAB) stage [19].”
BackgroundMethodZheng, L., Kandula, R. P., Kandasamy, K., & Divan, D. M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101811 · Cited by 26
“[6], PV farms [7], microgrids [8], MVdc grids [9], etc.”
BackgroundTransformer Based 25-Level T-Type MLI for Renewable Energy Integration
Molli, K., Raj, P. A. D. V., & Subramaniam, N. P. (2022) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2022.3164252 · Cited by 23
“The transformer-based multilevel topologies has been presented in [15]–[17].”
MethodSaha, J., Gorla, N. B. Y., & Panda, S. K. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3362830 · Cited by 23
Lin, H., Mehrabankhomartash, M., Yang, F., Saeedifard, M., Yang, J., & Shu, Z. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3128888 · Cited by 22
Unified Description and Optimization Method of Dual Active Bridge DC–DC Converters
Xiao, Z., He, Z., Li, Z., Zhu, L., & Wang, L. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3177245 · Cited by 22
Self-citationMedium Voltage Solid State Transformer for Extreme Fast Charging Applications
Awal, M. A., Montes, O. A., Teng, F., Wang, D., Bipu, M. R. H., Yu, W., Lukic, S. M., & Husain, I. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131285 · Cited by 24
Sadigh, A. K., Dargahi, V., & Corzine, K. A. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2613987 · Cited by 22
Babkrani, Y., Naddami, A., & Hilal, M. (2019) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v10.i4.pp1852-1862 · Cited by 22
“Thus it is a wiser decision for governments all around the world to reduce their dependency on such traditional types of energy and replace it with other sources of energy that can be safer, cheaper cleaner and renewable, solar energy is undeniably one of these sources, using solar radiation to produce the heat and el…”
Model Predictive Control of Dual Active Bridge Converter Based on the Lookup Table Method
Gao, G., Lei, W., Cui, Y., Li, K., Hu, X., Xu, J., & Lv, G. (2019) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2019.8807650 · Cited by 21
Power Electronics Converters for the Internet of Energy: A Review
Granata, S., Benedetto, M. D., Terlizzi, C., Leuzzi, R., Bifaretti, S., & Zanchetta, P. (2022) · Energies · doi:10.3390/en15072604 · Cited by 22
Tanguturi, J., & Keerthipati, S. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3330519 · Cited by 21
A Hybrid Data-Driven Power Loss Minimization Method of Dual-Active Bridge Converters
Xiao, Z., Jiang, Y. Y., Yao, Z., He, Z., Jiang, Y., Li, Y., & Tang, Y. K. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3368330 · Cited by 21
Electric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer
Huang, P., Mao, C., & Wang, D. (2017) · Energies · doi:10.3390/en10030371 · Cited by 22
Review on design and control of solid state transformer based microgrids
de Silva, H. H. H., Jayamaha, D. K. J. S., & Lidula, N. W. A. (2019) · AIMS energy · doi:10.3934/energy.2019.6.901 · Cited by 22
Types of inverters and topologies for microgrid applications
de Santander, U. I., Bastidas‐Rodríguez, J. D., Ramos‐Paja, C. A., & de Colombia, U. N. (2017) · Revista UIS Ingenierías · doi:10.18273/revuin.v16n1-2017001 · Cited by 20
“A widely used multilevel inverter topology is the Cascaded HBridge (CHB) inverter [21]–[23].”
BackgroundMethodSolid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
Model predictive control of matrix converter based solid state transformer
Liu, Y., Liu, Y., Abu‐Rub, H., & Ge, B. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474933 · Cited by 19
“In order to handle the HV level while maintaining the high power density, modular series connection at HV side and series/parallel connection at the LV side were developed, leading to more power devices [8], [9]; or control scheme has to be elaborately designed to reduce that dc-link capacitance [10].”
Li, Y., Li, Y., Han, J., Tan, Y., Cai, Y., & Jiang, Y. (2016) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2016.7555444 · Cited by 21
Liu, Z., Wang, T., Tang, T., & Wang, Y. (2017) · Energies · doi:10.3390/en10091273 · Cited by 19
Self-citationGeneral High-Frequency-Link Analysis and Application of Dual Active Bridge Converters
Xiao, Z., He, Z., Wang, H., Luo, A., Shuai, Z., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2963746 · Cited by 19
“like phase-shift full bridge converters (PSFB), resonant or multiresonant converters, and dual active bridge converters (DAB) are widely adopted in battery charger [10]–[12], automotive application [13]–[16], solid-state transformer [17]–[22], photovoltaic application [23], [24], and dc microgrid [25], [26].”
BackgroundChakraborty, S. S., Hatua, K., & Bhattacharya, S. (2023) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2023.3243844 · Cited by 18
“In the applications, such as SST for a distribution generation [18] and pulsed power loads [19], where the system experiences frequent load fluctuations, keeping low settling time for the reactive power control loop will cause significant switching loss and conduction loss.”
BackgroundMethodZhang, J., Li, L., Malekjamshidi, Z., & Dorrell, D. G. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096597 · Cited by 18
Power Balance Control of Cascaded Matrix-Based Dual-Active-Bridge Converter
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379382 · Cited by 18
A Three-Phase Reduced Switch Count Multilevel Inverter Topology
Sivamani, S., & Mohan, V. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/6193731 · Cited by 18
“Te topology requires independent control strategies to regulate the dc-link voltages and balance the three-phase grid currents [27].”
BackgroundChoudhary, A., Kumar, R., Letha, S. S., Bakhsh, F. I., Singh, A., & Khan, M. J. (2024) · IET Power Electronics · doi:10.1049/pel2.12564 · Cited by 17
Tian, J., Hu, D., Zhou, C., Yang, Y., Wu, W., Mao, C., & Wang, D. (2019) · IEEE Access · doi:10.1109/access.2019.2905006 · Cited by 13
Chen, M., Xia, M., & Chen, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2946865 · Cited by 18
Itoh, J., Aoyagi, K., Kusaka, K., & Adachi, M. (2019) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.8.795 · Cited by 17
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9807000 · Cited by 16
Metadata
- Authors
- Wang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S.
- Affiliations
- Harbin Institute of Technology (CN)
- Toronto Metropolitan University (CA)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-04
- Volume
- 31
- Issue
- 4
- Pages
- 3289-3301
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2176835823
- Cited by
- 285
- References
- 26
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 20 · 2023: 27 · 2022: 33 · 2021: 33 · 2020: 39 · 2019: 38 · 2018: 31 · 2017: 30 · 2016: 15
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (51247009)
- Shenzhen Science and Technology Plan Project (JCYJ20140417172417127)
- China Academy of Space Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, cascaded H-bridge inverter, power balance control, master-slave control, dual active bridge converter, DC-link voltage balancing, microgrids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.