An Improved Distributed Secondary Control Method for DC Microgrids With Enhanced Dynamic Current Sharing Performance
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
This paper proposes an improved distributed secondary control scheme for dc microgrids (MGs), aiming at overcoming the drawbacks of conventional droop control method. The proposed secondary control scheme can remove the dc voltage deviation and improve the current sharing accuracy by using voltage-shifting and slope-adjusting approaches simultaneously. Meanwhile, the average value of droop coefficients is calculated, and then it is controlled by an additional controller included in the distributed secondary control layer to ensure that each droop coefficient converges at a reasonable value. Hence, by adjusting the droop coefficient, each participating converter has equal output impedance, and the accurate proportional load current sharing can be achieved with different line resistances. Furthermore, the current sharing performance in steady and transient states can be enhanced by using the proposed method. The effectiveness of the proposed method is verified by detailed experimental tests based on a 3 × 1 kW prototype with three interface converters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 10×
“It can be seen from (1) that the secondary control method in [27] can be regarded as a voltage-shifting-based method.”
BackgroundMethodInfluentialDC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Self-citationDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Self-citationDistributed Secondary Control for Islanded Microgrids—A Novel Approach
Shafiee, Q., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2259506 · Cited by 1,069
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Self-citationLow-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Distributed Cooperative Control of DC Microgrids
Nasirian, V., Moayedi, S., Davoudi, A., & Lewis, F. L. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2324579 · Cited by 971
Anand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
Supervisory Control of an Adaptive-Droop Regulated DC Microgrid With Battery Management Capability
Dragicevic, T., Guerrero, J. M., Vasquez, J. C., & Skrlec, D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257857 · Cited by 770
Lu, X., Sun, K., Guerrero, J. M., Vasquez, J. C., & Huang, L. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279374 · Cited by 752
Self-citation
Cited by
Review on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Self-citationDistributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Primary and secondary control in DC microgrids: a review
GAO, F., KANG, R., CAO, J., & YANG, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-018-0466-5 · Cited by 314
Review of hierarchical control strategies for DC microgrid
Abhishek, A., Ranjan, A., Devassy, S., Kumar Verma, B., Ram, S. K., & Dhakar, A. K. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.1136 · Cited by 195
Plug-and-Play Robust Voltage Control of DC Microgrids
Sadabadi, M. S., Shafiee, Q., & Karimi, A. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2728319 · Cited by 167
Zhang, Q., Zeng, Y., Hu, Y., Liu, Y., Zhuang, X., & Guo, H. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3184841 · Cited by 40
“5A in the method proposed in [10], and the load power that DG1 cannot bear is shared by other DGs.”
BackgroundMethodInfluentialDesign of Space Microgrid for Manned Lunar Base: Spinning-in Terrestrial Technologies
Bintoudi, A. D., Timplalexis, C., Mendes, G., Guerrero, J. M., & Demoulias, C. (2019) · 2019 European Space Power Conference (ESPC) · doi:10.1109/espc.2019.8932024 · Cited by 23
“The authors of [50] suggest an improved distributed secondary control scheme, which is a hybrid scheme of voltage shifting and slope adjusting.”
Background
Metadata
- Authors
- Wang, P., Lu, X., Yang, X., Wang, W., & Xu, D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-09
- Volume
- 31
- Issue
- 9
- Pages
- 6658-6673
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2311260476
- Cited by
- 364
- References
- 31
- FWCI
- 25.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.