Open-Circuit Fault Diagnosis and Fault-Tolerant Control for a Grid-Connected NPC Inverter
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper presents an open-circuit fault detection method for a grid-connected neutral-point clamped (NPC) inverter system. Further, a fault-tolerant control method under an open-circuit fault in clamping diodes is proposed. Under the grid-connected condition, it is impossible to identify the location of a faulty switch by the conventional methods which usually use the distortion of outputs because the distortion of the outputs is the same in some fault cases. The proposed fault detection method identifies the location of the faulty switch and the faulty clamping diode of the NPC inverter without any additional hardware or complex calculations. In the case of the clamping diode faults, the NPC inverter can transfer full rated power with sinusoidal currents by the proposed fault-tolerant control. The feasibility of the proposed fault detection and the fault-tolerant control methods for the grid-connected NPC inverter are verified by simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139 · cited 1×
“Finally, it can improve the efficiency compared with the conventional two-level converter in certain switching frequency ranges [10]–[12].”
BackgroundA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621 · cited 1×
“The power electronic converters which convert electrical power efficiently from one stage to another stage play an important role in various applications to achieve high efficiency and also achieve high performance of the systems [1].”
BackgroundSelf-citationAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019 · cited 1×
“selected by 34% of responders as the most fragile components [5].”
BackgroundThe age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016
High‐Power Converters and ac Drives
Wu, B. (2006) · Wiley eBooks · doi:10.1002/0471773719 · Cited by 1,640
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“vice failure accounts for total 21% of converter system’s failures [4].”
BackgroundSelected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916 · cited 2×
“As the power electronics has progressively gained an important status in power generation, distribution, and consumption, recent research endeavor to improve the reliability of the power electronic systems to comply with more stringent constraints on cost, safety, and availability in various applications [2], [3].”
BackgroundSelf-citationSemiconductor Power Devices: Physics, Characteristics, Reliability
Lutz, J., Schlangenotto, H., Scheuermann, U., & De Doncker, R. (2011) · Springer eBooks · doi:10.1007/978-3-642-11125-9 · Cited by 706
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700 · cited 2×
“Several methods to detect the open-circuit fault have been proposed such as the current pattern method, slope method, and dc current method [13], [14].”
MethodSelf-citationTransitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693 · cited 1×
“As the power electronics has progressively gained an important status in power generation, distribution, and consumption, recent research endeavor to improve the reliability of the power electronic systems to comply with more stringent constraints on cost, safety, and availability in various applications [2], [3].”
BackgroundSelf-citationEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 1×
“Most of previous methods can detect the open-circuit fault by analyzing the distortion of the output currents [13]–[16].”
Design for reliability of power electronic systems
Wang, H., Ma, K., & Blaabjerg, F. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6388833 · Cited by 313
Self-citationA New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems
Choi, U.-M., Lee, K.-B., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2269531 · Cited by 257 · cited 1×
“The phase currents can be normalized as given by (1) and (2) [24]”
BackgroundSelf-citationLee, J.-S., Lee, K., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2327151 · Cited by 172 · cited 1×
“In [19], the slope method is applied for back-to-back NPC converter for wind turbine system.”
MethodSelf-citationCaseiro, L. M. A., & Mendes, A. M. S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2341558 · Cited by 170 · cited 1×
“Besides above mentioned methods, there are many methods to detect the faulty switch in the NPC converter based on the distortions of the outputs like current, voltage, and etc [22]-[23].”
MethodChoi, U., Lee, J.-S., & Lee, K. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2013.2293502 · Cited by 150 · cited 1×
“The two-level switching method can be implemented by adding an offset time (Toffset) to the turn-on time of the faulty phase as below [25]”
MethodSelf-citationDetection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems
Kim, T., Lee, W., & Hyun, D.-S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2019775 · Cited by 139 · cited 2×
“In [20], the pole voltage is measured by the additional hardware circuit.”
MethodMendes, A. M. S., Abadi, M. B., & Cruz, S. M. A. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2013.0416 · Cited by 95
Three-level NPC inverter fault diagnosis by the Average Current Park's Vector approach
Abadi, M. B., Mendes, A. M. S., & Cruz, S. M. A. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350140 · Cited by 51 · cited 1×
“In [17], the current vector method is applied to the NPC inverter for the ac motor driver.”
MethodA new fault detection method for NPC converters
Fazio, P., Maragliano, G., Marchesoni, M., & Parodi, G. (2011) · CINECA IRIS Institutial Research Information System (University of Genoa) · Cited by 29
Ku, H.-K., & Kim, J.-M. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699280 · Cited by 15
Cited by
Xu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3128417 · Cited by 262
“Fault tolerance × √ [129] × [130] Fault ride-through capability × × [131] √ [131] × [132]”
Metadata
- Authors
- Choi, U.-M., Lee, J.-S., Blaabjerg, F., & Lee, K.-B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015
- Pages
- 1-1
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2344926255
- Cited by
- 252
- References
- 24
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.