Higher Order Compensation for Inductive-Power-Transfer Converters With Constant-Voltage or Constant-Current Output Combating Transformer Parameter Constraints
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Compensation is crucial for improving performance of inductive-power-transfer (IPT) converters. With proper compensation at some specific frequencies, an IPT converter can achieve load-independent constant output voltage or current, near zero reactive power, and soft switching of power switches simultaneously, resulting in simplified control circuitry, reduced component ratings, and improved power conversion efficiency. However, constant output voltage or current depends significantly on parameters of the transformer, which is often space constrained, making the converter design hard to optimize. To free the design from the constraints imposed by the transformer parameters, this paper proposes a family of higher order compensation circuits for IPT converters that achieves any desired constant-voltage or constant-current (CC) output with near zero reactive power and soft switching. Detailed derivation of the compensation method is given for the desired transfer function not constrained by transformer parameters. Prototypes of CC IPT configurations based on a single transformer are constructed to verify the analysis with three different output specifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern Trends in Inductive Power Transfer for Transportation Applications
Covic, G. A., & Boys, J. T. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2264473 · Cited by 1,263
Covic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223 · cited 1×
“transfer systems [1].”
Wang, C.-S., Covic, G. A., & Stielau, O. H. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.822038 · Cited by 1,213 · cited 1×
“Besides, the use of frequency control for an IPT converter may create stability issues [22], [23].”
BackgroundA Double-Sided LCC Compensation Network and Its Tuning Method for Wireless Power Transfer
Li, S., Li, W., Deng, J., Nguyen, T. D., & Mi, C. C. (2015) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2347006 · Cited by 1,091 · cited 1×
“Besides the four basic compensations, there are some other higher order compensation topologies that have been used in some previous work, such as LCC/LCC [12] and S/SP [34], both realizing the ZPA for a range of load.”
MethodDesign and Optimization of Circular Magnetic Structures for Lumped Inductive Power Transfer Systems
Budhia, M., Covic, G. A., & Boys, J. T. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143730 · Cited by 1,039 · cited 1×
“The authors of [2] and [21] use frequency control to fully compensate the reactive power, and the output is regulated by a downstream converter.”
BackgroundOptimal Design of ICPT Systems Applied to Electric Vehicle Battery Charge
Sallan, J., Villa, J. L., Llombart, A., & Sanz, J. F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2015359 · Cited by 734
Planar Wireless Charging Technology for Portable Electronic Products and Qi
Hui, S. Y. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2246531 · Cited by 648
Khaligh, A., & Dusmez, S. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2213104 · Cited by 630 · cited 1×
“Recently, due to the improved transfer efficiency, IPT technologies have become popular for a range of battery charging applications including low-power consumer electronics [2]–[4], high-power electric vehicles (EVs) [5]–[13], home appliances involving LED lighting [14]–[17], biomedical implants [18], [19], and so on.”
BackgroundA Frequency Control Method for Regulating Wireless Power to Implantable Devices
Si, P., Hu, A. P., Malpas, S., & Budgett, D. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918284 · Cited by 582
A contactless electrical energy transmission system for portable-telephone battery chargers
Jang, Y., & Jovanovic, M. M. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.812472 · Cited by 484
Metadata
- Authors
- Qu, X., Jing, Y., Han, H., Wong, S.-C., & Tse, C. K.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-01
- Volume
- 32
- Issue
- 1
- Pages
- 394-405
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2322331227
- Cited by
- 216
- References
- 26
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Higher Order Compensation for Inductive-Power-Transfer Converters With Constant-Voltage or Constant-Current Output Combating Transformer Parameter Constraints. https://app.cochat.ai/papers/10.1109/tpel.2016.2535376
- The paper
- Qu, X., Jing, Y., Han, H., Wong, S.-C., & Tse, C. K. (2017). Higher Order Compensation for Inductive-Power-Transfer Converters With Constant-Voltage or Constant-Current Output Combating Transformer Parameter Constraints. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2535376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.