A high-voltage-gain dc-dc converter based on modified dickson charge pump voltage multiplier
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A high-voltage-gain dc-dc converter is introduced in this paper. The proposed converter resembles a two-phase interleaved boost converter on its input side while having a Dickson-charge-pump-based voltage multiplier (VM) on its output side. This converter offers continuous input current, which makes it more appealing for the integration of renewable sources like solar panels to a 400-V dc bus. Also, the proposed converter is capable of drawing power from either a single source or two independent sources. Furthermore, the VM used offers low voltage ratings for capacitors that potentially leads to size reduction. The converter design and component selection have been discussed in detail with supporting simulation results. A hardware prototype of the proposed converter with Vin= 20 and Vout= 400 V has been developed to validate the analytical results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonisolated High Step-Up DC–DC Converters Adopting Switched-Capacitor Cell
Wu, G., Ruan, X., & Ye, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2327000 · Cited by 408
Ajami, A., Ardi, H., & Farakhor, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360495 · Cited by 406
A DC–DC Converter With High Voltage Gain and Two Input Boost Stages
Prabhala, V. A. K., Fajri, P., Gouribhatla, V. S. P., Baddipadiga, B. P., & Ferdowsi, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2476377 · Cited by 353
Self-citationA High Voltage Gain DC–DC Converter Integrating Coupled-Inductor and Diode–Capacitor Techniques
Hu, X., & Gong, C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257870 · Cited by 347 · cited 1×
“High-voltage-gain dc-dc converters using coupled inductors and high frequency transformers have been proposed for the integration of solar panels to 400V dc bus [12-18].”
BackgroundA Switched-Capacitor-Based Active-Network Converter With High Voltage Gain
Tang, Y., Wang, T., & He, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2272639 · Cited by 317
Edison Redux: 380 Vdc Brings Reliability and Efficiency to Sustainable Data Centers
AlLee, G., & Tschudi, W. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212607 · Cited by 273 · cited 1×
“INTRODUCTION Distribution systems at 400-V dc have been gaining popularity as they offer better efficiency, higher reliability at an improved power quality, and low cost compared to ac distribution systems [1-4].”
BackgroundDC microgrids in buildings and data centers
Becker, D. J., & Sonnenberg, B. J. (2011) · 2011 IEEE 33rd International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.2011.6099725 · Cited by 178 · cited 1×
“Currently, telecom centers, data centers, commercial buildings, residential buildings, and microgrids are among the emerging examples of dc distribution systems [5-7].”
BackgroundA New Hybrid Boosting Converter for Renewable Energy Applications
Wu, B., Li, S., Liu, Y., & Ma Smedley, K. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2420994 · Cited by 177
Li, W., Li, W., Xiang, X., Hu, Y., & He, X. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273977 · Cited by 173
Wu, H., Mu, T., Ge, H., & Xing, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2425956 · Cited by 152
An overview of low voltage DC distribution systems for residential applications
Rodriguez-Diaz, E., Savaghebi, M., Vásquez, J. C., & Guerrero, J. M. (2015) · IEEE International Conference on Consumer Electronics - Berlin (ICCE-Berlin) · doi:10.1109/icce-berlin.2015.7391268 · Cited by 127 · cited 1×
“Currently, telecom centers, data centers, commercial buildings, residential buildings, and microgrids are among the emerging examples of dc distribution systems [5]–[7].”
BackgroundA High Step-Up Converter With Voltage-Multiplier Modules for Sustainable Energy Applications
Tseng, K., Huang, C.-C., & Cheng, C. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2404943 · Cited by 82
Li, W., Xu, C., Yu, H., Gu, Y., & He, X. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0072 · Cited by 47
DC distribution systems — An overview
Prabhala, V. A. K., Baddipadiga, B. P., & Ferdowsi, M. (2014) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2014.7016575 · Cited by 36 · cited 1×
“D ISTRIBUTION systems at 400 V dc have been gaining popularity as they offer better efficiency, higher reliability at an improved power quality, and low cost compared to ac distribution systems [1]–[4].”
BackgroundSelf-citationMarshall, B. R., Morys, M. M., & Durgin, G. D. (2015) · IEEE International Conference on RFID · doi:10.1109/rfid.2015.7113070 · Cited by 35
Cited by
Anand, P., Singh, Y., Selwal, A., Alazab, M., Tanwar, S., & Kumar, N. (2020) · IEEE Access · doi:10.1109/access.2020.3022842 · Cited by 159
Wu, X., Wang, J., Zhang, Y., Du, J., Liu, Z., & Chen, Y. (2021) · Automotive Innovation · doi:10.1007/s42154-021-00163-z · Cited by 42
Metadata
- Authors
- Baddipadiga, B. P., & Ferdowsi, M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-10
- Volume
- 32
- Issue
- 10
- Pages
- 7707-7715
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2489985317
- Cited by
- 223
- References
- 15
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.