Thermal Stress Analysis of Medium-Voltage Converters for Smart Transformers
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A smart transformer (ST) can take over an important managing role in the future electrical distribution grid system and can provide many advanced grid services compared to the traditional transformer. However, the risk is that the advanced functionality is balanced out by a lower reliability. To address this concern, this work conducts thermal stress analysis for a modular multilevel converter (MMC), which is a promising solution for the medium voltage stage of the ST. The focus is put on the mission profiles of the transformer and the impact on the thermal stress of power semiconductor devices. Normal operation at different power levels and medium voltage grid faults in a feeder fed by a traditional transformer are considered as well as the electrical and the thermal stress of the disconnection and the reconnection procedures. For the validation, the thermal stress of one MMC cell is reproduced on a laboratory setup with high-speed temperature measurement. It is concluded that the investigated conditions, including inrush currents and power variations, do not cause a significant lifetime reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039 · cited 2×
“Nevertheless, the failure mechanisms and the dependence on the temperature swing remains [30].”
BackgroundTransitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693 · cited 1×
“The existing research for reliability is mainly limited to the studies of component counts and redundancy, whereas the actual operating status or mission profiles like the control behaviors or the grid conditions are often neglected [9].”
BackgroundSelf-citationGlobal Energy Scenario and Impact of Power Electronics in 21st Century
Bose, B. K. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2203771 · Cited by 476 · cited 1×
“This changes the concept of large centralized power plants for which the actual electrical distribution system is designed [1], [2].”
BackgroundThe Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 2×
“In contrast to other applications, the ST enables to partially shape its mission profile by providing services to the grid, which are not mandatory to the current state, but put loading on the devices [2].”
BackgroundSelf-citationNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Cited by
Junction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
Self-citationSizing and SOC Management of a Smart-Transformer-Based Energy Storage System
Kumar, C., Zhu, R., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784389 · Cited by 71
“However, research on improving the reliability of actual solutions [10] as well as in improving the materials has already shown possibility of improvement.”
BackgroundSelf-citationDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
Xu, J., Yu, Y., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868772 · Cited by 14
Load-Dependent Active Thermal Control of Grid-Forming Converters
Andresen, M., De Carne, G., & Liserre, M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2966573 · Cited by 10
Self-citation
Metadata
- Authors
- Andresen, M., Ma, K., De Carne, G., Buticchi, G., Blaabjerg, F., & Liserre, M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-06
- Volume
- 32
- Issue
- 6
- Pages
- 4753-4765
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2549420021
- Cited by
- 38
- References
- 6
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal Stress Analysis of Medium-Voltage Converters for Smart Transformers. https://app.cochat.ai/papers/10.1109/tpel.2016.2600270
- The paper
- Andresen, M., Ma, K., De Carne, G., Buticchi, G., Blaabjerg, F., & Liserre, M. (2017). Thermal Stress Analysis of Medium-Voltage Converters for Smart Transformers. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2600270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.