CoChat

The Extended Overlap Alternate Arm Converter: A Voltage-Source Converter With DC Fault Ride-Through Capability and a Compact Design

Open access
Merlin, Michael Marc Claude, Soto-Sanchez, Diego, Judge, Paul Daniel, Chaffey, Geraint, Clemow, Philip, Green, Tim C., Trainer, David R., Dyke, Kevin J. · 2018 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 45 of the 54 references it cites were found in a registry or an index.

Abstract

The alternate arm converter (AAC) was one of the first modular converter topologies to feature dc-side fault ride-through capability with only a small penalty in power efficiency. However, the simple alternation of its arm conduction periods (with an additional short overlap period) resulted in 1) substantial six-pulse ripples in the dc current waveform, 2) large dc-side filter requirements, and 3) limited operating area close to an energy sweet spot. This paper presents a new mode of operation called extended overlap (EO) based on the extension of the overlap period to 60°, which facilitates a fundamental redefinition of the working principles of the AAC. The EO-AAC has its dc current path decoupled from the ac current paths, a fact allowing 1) smooth dc current waveforms, 2) elimination of dc filters, and 3) restriction lifting on the feasible operating point. Analysis of this new mode and EO-AAC design criteria are presented and subsequently verified with tests on an experimental prototype. Finally, a comparison with other modular converters demonstrates that the EO-AAC is at least as power efficient as a hybrid modular multilevel converter (MMC) (i.e., a dc fault ride-through-capable MMC), while offering a smaller converter footprint because of a reduced requirement for energy storage in the submodules and a reduced inductor volume.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2017.2723948

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 45 references

Research works printed but not linked: 6

  1. trainer, 2010, A new hybrid voltage-sourced converter for HVDC power transmission, Proc CIGRE Session, 4b
  2. ahmed, 2011, Prospects and challenges of future HVDC supergrids with modular multilevel converters, Proc 14th IEEE Appl Power Electron Conf, 1
  3. 2014, Terminology for Voltage-Sourced Converters for High-Voltage Direct Current Systems BS EN 62747 2014
  4. 2014, Power Losses in Voltage Sourced Converter (VSC) Valves for High-Voltage Direct Current Systems Part 2 Modular Multilevel Converters BS EN 62751–2 2014
  5. 2014, Power Losses in Voltage Sourced Converter (VSC) Valves for High-Voltage Direct Current Systems Part 1 General Requirements BS EN 62751–1 2014
  6. judge, 2015, Hardware testing of the alternate arm converter operating in its extended overlap mode, Cigre HVDC

Cited by

See all 148

Metadata

Authors
Merlin, M. M. C., Soto-Sanchez, D., Judge, P. D., Chaffey, G., Clemow, P., Green, T. C., Trainer, D. R., & Dyke, K. J.
Affiliations
Imperial College London (GB)
Venue
IEEE Transactions on Power Electronics
Published
2018-05
Volume
33
Issue
5
Pages
3898-3910
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2742461864
Cited by
142
References
54
Citations by year
2026: 5 · 2025: 7 · 2024: 11 · 2023: 22 · 2022: 20 · 2021: 15 · 2020: 23 · 2019: 18 · 2018: 19
FWCI
7.05
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Power Electronics (publishedVersion, cc-by)
  • Edinburgh Research Explorer (University of Edinburgh) (submittedVersion, cc-by)
  • Spiral (Imperial College London) (submittedVersion, cc-by)
Funders
Engineering and Physical Sciences Research Council (EP/I013636/1, EP/K035096/1, EP/L014351/1)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
Keywords
alternate arm converter, modular multilevel converter, DC fault ride-through, voltage source converter, DC current ripple, power efficiency

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.