The Extended Overlap Alternate Arm Converter: A Voltage-Source Converter With DC Fault Ride-Through Capability and a Compact Design
Open accessThe DOI matches its Crossref record; 45 of the 54 references it cites were found in a registry or an index.
Abstract
The alternate arm converter (AAC) was one of the first modular converter topologies to feature dc-side fault ride-through capability with only a small penalty in power efficiency. However, the simple alternation of its arm conduction periods (with an additional short overlap period) resulted in 1) substantial six-pulse ripples in the dc current waveform, 2) large dc-side filter requirements, and 3) limited operating area close to an energy sweet spot. This paper presents a new mode of operation called extended overlap (EO) based on the extension of the overlap period to 60°, which facilitates a fundamental redefinition of the working principles of the AAC. The EO-AAC has its dc current path decoupled from the ac current paths, a fact allowing 1) smooth dc current waveforms, 2) elimination of dc filters, and 3) restriction lifting on the feasible operating point. Analysis of this new mode and EO-AAC design criteria are presented and subsequently verified with tests on an experimental prototype. Finally, a comparison with other modular converters demonstrates that the EO-AAC is at least as power efficient as a hybrid modular multilevel converter (MMC) (i.e., a dc fault ride-through-capable MMC), while offering a smaller converter footprint because of a reduced requirement for energy storage in the submodules and a reduced inductor volume.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Alternate Arm Converter (AAC) topology, in which the arms are connected in series with a high voltage switch, as shown in Fig. 5(c), allows the activation or deactivation of the complete arm. Therefore, it provides better performance than the standard MMC in terms of circulating current, power losses, and capacitor voltage ripple [143].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [143]
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 2×
“The well-established modular multilevel converter (MMC) [4] offers both high power efficiency and high-quality waveforms.”
BackgroundMethodCircuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 2×
“by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the double clamped submodule [21]–[24] and other designs [17], [25]–[27].”
BackgroundMethodModular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
HVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909 · cited 1×
“any further rectification of ac-side fault current [9], and on multiterminal schemes, dc circuit breakers [10]–[14] are needed in order to prevent the entire dc grid from being blacked out as a result of a single dc-side fault.”
BackgroundMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773 · cited 1×
“by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the double clamped submodule [21]–[24] and other designs [17], [25]–[27].”
MethodDesign, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems
Sharifabadi, K., Harnefors, L., Nee, H., Norrga, S., & Teodorescu, R. (2016) · Wiley eBooks · doi:10.1002/9781118851555 · Cited by 678
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640 · cited 1×
“any further rectification of ac-side fault current [9], and on multiterminal schemes, dc circuit breakers [10]–[14] are needed in order to prevent the entire dc grid from being blacked out as a result of a single dc-side fault.”
BackgroundProactive Hybrid HVDC Breakers - A key Innovation for Reliable HVDC Grids
Häfner, J., & Jacobson, B. (2011) · Medical Entomology and Zoology · Cited by 556
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455 · cited 3×
“Here, the H-MMC is taken to have the same number of SMs as the HB-MMC but with half of them replaced by full-bridge SMs [16].”
MethodResultModular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413
Meshram, P. M., & Borghate, V. B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2317705 · Cited by 405 · cited 1×
“Finally, the “Low Level Controller” converts the stack voltage commands into individual SM firing commands, taking into account the state of their respective DS and voltage deviations between the individual SMs using sorting algorithms similar to [49], [50].”
MethodThe Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
Merlin, M. M. C., Green, T. C., Mitcheson, P. D., Trainer, D. R., Critchley, R., Crookes, W., & Hassan, F. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2282171 · Cited by 402 · cited 5×
“The alternate arm converter (AAC) [28], [33], [34] is a hybrid between the two-level converter [in the”
BackgroundMethodResultInfluentialSelf-citationHybrid Design of Modular Multilevel Converters for HVDC Systems Based on Various Submodule Circuits
Qin, J., Saeedifard, M., Rockhill, A., & Zhou, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2351794 · Cited by 358 · cited 2×
“by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the double clamped submodule [21]–[24] and other designs [17], [25]–[27].”
MethodResultOn Energy Storage Requirements in Modular Multilevel Converters
Ilves, K., Norrga, S., Harnefors, L., & Nee, H.-P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254129 · Cited by 353 · cited 1×
“These improvements have been made possible, thanks to the use of many submodules (SMs) connected in series in stacks and the charged SM capacitors [5]–[7] switched in the arm current conduction path one at a time.”
BackgroundVSC-HVDC Transmission with Cascaded Two-Level Converters
Jacobson, B., Karlsson, P., Asplund, G., Harnefors, L., & Jönsson, T. (2010) · Cited by 326
Parameter design principle of the arm inductor in modular multilevel converter based HVDC
Tu, Q., Xu, Z., Huang, H., & Zhang, J. (2010) · 2010 International Conference on Power System Technology · doi:10.1109/powercon.2010.5666416 · Cited by 238 · cited 3×
“to limit the rate of rise of the current in the case of a dc-side fault, as detailed in [8].”
BackgroundResultFull-Bridge MMC Converter Optimal Design to HVDC Operational Requirements
Lin, W., Jovcic, D., Nguefeu, S., & Saad, H. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2475130 · Cited by 224 · cited 1×
“by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the double clamped submodule [21]–[24] and other designs [17], [25]–[27].”
MethodMerlin, M. M. C., & Green, T. C. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0328 · Cited by 216 · cited 4×
“It was estimated in [7] that a dc-bus capacitance equivalent to two additional stacks worth of SM capacitors would be needed with the SO-AAC.”
BackgroundMethodInfluentialSelf-citationCui, S., & Sul, S.-K. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513426 · Cited by 210
A new hybrid multi-level voltage-source converter with DC fault blocking capability
Merlin, M. M. C., Green, T. C., Mitcheson, P. D., Trainer, D. R., Critchley, D. R., & Crookes, R. W. (2010) · 9th IET International Conference on AC and DC Power Transmission (ACDC 2010) · doi:10.1049/cp.2010.0987 · Cited by 210 · cited 1×
“The alternate arm converter (AAC) [28], [33], [34] is a hybrid between the two-level converter [in the”
BackgroundSelf-citationBarnes, M., Van Hertem, D., Teeuwsen, S. P., & Callavik, M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2672879 · Cited by 209 · cited 1×
“networks [2], [3].”
Integrated current control, energy control and energy balancing of Modular Multilevel Converters
Munch, P., Gorges, D., Izak, M., & Liu, S. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5675185 · Cited by 173 · cited 1×
“It operation is closely related to the one of the MMC [44],”
BackgroundA Hybrid Modular Multilevel Voltage Source Converter for HVDC Power Transmission
Feldman, R., Tomasini, M., Amankwah, E., Clare, J. C., Wheeler, P. W., Trainer, D. R., & Whitehouse, R. S. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2257636 · Cited by 165
Self-citationImpacts of Three MMC-HVDC Configurations on AC System Stability Under DC Line Faults
Tang, G., Xu, Z., & Zhou, Y. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2315666 · Cited by 164
Ilves, K., Harnefors, L., Norrga, S., & Nee, H.-P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2308018 · Cited by 151
Static VAr compensator (STATCOM) based on single-phase chain circuit converters
Ainsworth, J. D., Davies, M., Fitz, P. J., Owen, K. E., & Trainer, D. R. (1998) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19982032 · Cited by 141 · cited 1×
“the AAC can also act as a STATCOM in order to support the ac grid [34], [38], [39], similar to the system described in [40].”
ResultSelf-citationInnovative concepts for hybrid multi-level converters for HVDC power transmission
Davidson, C. C., & Trainer, D. R. (2010) · 9th IET International Conference on AC and DC Power Transmission (ACDC 2010) · doi:10.1049/cp.2010.0982 · Cited by 128
Self-citationModéer, T., Nee, H., & Norrga, S. (2012) · EPE Journal · doi:10.1080/09398368.2012.11463829 · Cited by 120
Future HVDC-grids employing modular multilevel converters and hybrid DC-breakers
Wang, Y., & Marquardt, R. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6631861 · Cited by 116 · cited 1×
“However, the previously proposed operating mode of the AAC exhibits several shortcomings [11], [41].”
BackgroundA Hybrid Modular Multilevel Converter With Novel Three-Level Cells for DC Fault Blocking Capability
Li, R., Fletcher, J. E., Xu, L., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2423258 · Cited by 115
Operating DC Circuit Breakers With MMC
Cwikowski, O., Wood, A. R., Miller, A., Barnes, M., & Shuttleworth, R. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2658540 · Cited by 92 · cited 1×
“any further rectification of ac-side fault current [9], and on multiterminal schemes, dc circuit breakers [10]–[14] are needed in order to prevent the entire dc grid from being blacked out as a result of a single dc-side fault.”
BackgroundNetwork fault tolerant voltage-source-converters for high-voltage applications
Adam, G. P., Finney, S. J., Williams, B., Trainer, D. R., Oates, C., & Critchley, D. (2010) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp.2010.0985 · Cited by 73
Self-citationCell capacitor sizing in modular multilevel converters and hybrid topologies
Merlin, M., Green, T. C., Mitcheson, P. D., Moreno, F., Dyke, K. J., & Trainer, D. R. (2014) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910972 · Cited by 72
Self-citationModeer, Nee, & Norrga (2011) · European Conference on Power Electronics and Applications · Cited by 72
STATCOM Operation Scheme of the CDSM-MMC During a Pole-to-Pole DC Fault
Yu, X., Wei, Y., & Jiang, Q. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2464320 · Cited by 66 · cited 1×
“Recent design innovations have helped the MMC to cope with these fault situations either by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the Double Clamped Submodule (DCS) [21]–[24] and other designs [17], [25]–[27].”
BackgroundAn improved modular multilevel converter with DC fault blocking capability
Zeng, R., Xu, L., & Yao, L. (2014) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2014.6938937 · Cited by 50 · cited 1×
“by using hybrid stacks consisting of both full- and half-bridge SMs [15]–[20] or new SM circuits such as the double clamped submodule [21]–[24] and other designs [17], [25]–[27].”
MethodEnergetic macroscopic representation and inversion based control of a modular multilevel converter
Delarue, P., Gruson, F., & Guillaud, X. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6631859 · Cited by 49 · cited 1×
“It operation is closely related to the one of the MMC [44], [45] and SO-AAC [34].”
BackgroundModeling and current control of modular multilevel converters considering actuator and sensor delays
Munch, P., Liu, S., & Dommaschk, M. (2009) · 2009 35th Annual Conference of IEEE Industrial Electronics · doi:10.1109/iecon.2009.5414756 · Cited by 48 · cited 1×
“The “Current Controller” compares these reference waveforms with the measured arm currents and computes the optimal stack voltage, similarly to the method described in [47] and [48].”
MethodFeldman, R., Tomasini, M., Wheeler, P. W., Clare, J., Trainer, D. R., & Whitehouse, R. S. (2010) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2010.0093 · Cited by 33
Self-citationDC fault ride‐through capability and STATCOM operation of a HVDC hybrid voltage source converter
Feldman, R., Farr, E., Watson, A. J., Clare, J., Wheeler, P. W., Trainer, D. R., & Crookes, R. W. (2014) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2012.0713 · Cited by 31 · cited 2×
“During such events, the AAC can also act as a STATCOM in order to support the AC grid [34], [38], [39], similar to the system described in [40].”
BackgroundResultSelf-citationZero phase sequence voltage injection for the alternate arm converter
Moreno, F. J., Trainer, D. R., Dyke, K. J., Merlin, M., & Green, T. C. (2015) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp.2015.0080 · Cited by 30 · cited 1×
“A means to mitigate this rating increase was suggested in [43] and consists in injecting a specific triplen harmonic voltage.”
BackgroundSelf-citationComparison of bipolar sub-modules for the alternate arm converter
Wickramasinghe, H. R., Konstantinou, G. S., & Pou, J. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.01.023 · Cited by 25
Feldman, R., Watson, A. J., Clare, J., Wheeler, P. W., Trainer, D. R., & Crookes, R. W. (2012) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2012.0343 · Cited by 19 · cited 2×
“the AAC can also act as a STATCOM in order to support the ac grid [34], [38], [39], similar to the system described in [40].”
BackgroundResultSelf-citationLab-scale experimental multilevel modular HVDC converter with temperature controlled cells
Clemow, P., Judge, P. D., Chaffey, G. P., Merlin, M., Luth, T., & Green, T. C. (2014) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910976 · Cited by 8 · cited 1×
“It was first presented in its prototype form in [51] and upgraded for [52].”
BackgroundSelf-citationControl of MMC converter integrated in HVDC link based on quadratic optimization approach
Belhaouane, M. M., Colas, F., Gruson, F., Braïek, N. B., & Guillaud, X. (2016) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2016.7556763 · Cited by 5 · cited 1×
“The “Current Controller” compares these reference waveforms with the measured arm currents and computes the optimal stack voltage, similarly to the method described in [47] and [48].”
Method
Research works printed but not linked: 6
- trainer, 2010, A new hybrid voltage-sourced converter for HVDC power transmission, Proc CIGRE Session, 4b
- ahmed, 2011, Prospects and challenges of future HVDC supergrids with modular multilevel converters, Proc 14th IEEE Appl Power Electron Conf, 1
- 2014, Terminology for Voltage-Sourced Converters for High-Voltage Direct Current Systems BS EN 62747 2014
- 2014, Power Losses in Voltage Sourced Converter (VSC) Valves for High-Voltage Direct Current Systems Part 2 Modular Multilevel Converters BS EN 62751–2 2014
- 2014, Power Losses in Voltage Sourced Converter (VSC) Valves for High-Voltage Direct Current Systems Part 1 General Requirements BS EN 62751–1 2014
- judge, 2015, Hardware testing of the alternate arm converter operating in its extended overlap mode, Cigre HVDC
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“losses, and capacitor voltage ripple [143].”
Nguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2862247 · Cited by 173
“The AAC arm consists of an active switch controlling the current direction and the FBSMs connected in series to produce the multilevel output voltages in positive and negative side [32], [69], [70].”
MethodReview of Hybrid Multilevel Converter Topologies Utilizing Thyristors for HVDC Applications
Bakas, P., Okazaki, Y., Shukla, A., Patro, S. K., Ilves, K., Dijkhuizen, F., & Nami, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2997961 · Cited by 112
“Another exception is the thyristor-based AAC that is not operated in the EO-AAC mode, which generates low-order current harmonics on the dc side [15].”
BackgroundMethodInfluentialBeyond the MMC: Extended Modular Multilevel Converter Topologies and Applications
Sun, P., Tian, Y., Pou, J., & Konstantinou, G. S. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3175714 · Cited by 108
Judge, P. D., & Green, T. C. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2874209 · Cited by 96
“If the proposed scheme was used in a converter topology that includes bipolar SMs as standard, such as the Hybrid MMC [25] or Alternate Arm Converter [26], then the negative voltage of the standard SMs could be used to partially compensate for this influence, and potentially reduce the required number of ESE-SMs below…”
MethodSelf-citation
Metadata
- Authors
- Merlin, M. M. C., Soto-Sanchez, D., Judge, P. D., Chaffey, G., Clemow, P., Green, T. C., Trainer, D. R., & Dyke, K. J.
- Affiliations
- Imperial College London (GB)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-05
- Volume
- 33
- Issue
- 5
- Pages
- 3898-3910
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2742461864
- Cited by
- 142
- References
- 54
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 11 · 2023: 22 · 2022: 20 · 2021: 15 · 2020: 23 · 2019: 18 · 2018: 19
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Power Electronics (publishedVersion, cc-by)
- Edinburgh Research Explorer (University of Edinburgh) (submittedVersion, cc-by)
- Spiral (Imperial College London) (submittedVersion, cc-by)
- Funders
- Engineering and Physical Sciences Research Council (EP/I013636/1, EP/K035096/1, EP/L014351/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- alternate arm converter, modular multilevel converter, DC fault ride-through, voltage source converter, DC current ripple, power efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.