Stability Improvement for Three-Phase Grid-Connected Converters Through Impedance Reshaping in Quadrature-Axis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Three-phase AC-DC and DC-AC power converters have been extensively employed as grid-interfaces in various applications, e.g., distributed generation and energy storage systems. In these applications, power converters should always synchronize with the mains grid so that active and/or reactive power can properly be regulated while maintaining desired waveforms of grid currents. Grid synchronization necessitates accurate information of grid voltages, which is normally obtained through phase-locked-loops (PLLs). However, the employment of PLLs may bring in stability concerns. Previous research revealed that the inclusion of PLLs shapes the impedance of power converters into a negative resistance in the quadrature-axis (q-axis), and this should be responsible for instability. To resolve the instability issue caused by PLLs, this paper proposes an impedance controller for reshaping the q-axis impedance into a positive resistance in the low-frequency band. Without any extra burden on system hardware, the proposed controller can easily be implemented by directly relating the q -axis voltage to the q-axis current reference. As a result, the presented three-phase power conversion system can operate stably even under a severely weak grid condition, which are verified by simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728 · cited 1×
“THREE-PHASE AC−DC and DC−AC voltage-source converters have found widespread applications in the fields covering from distributed generation to energy storage systems [1], [2].”
BackgroundSelf-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
Zhu, D., Zhou, S., Zou, X., & Kang, Y. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2943634 · Cited by 225
“Here, as analyzed in [13] and [32], the coupling and decoupling items are neglected to simplify the analysis, because the dq-axis decoupling control and the unity power factor control are used in this article.”
BackgroundMethodRavanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- Fang, J., Li, X., Li, H., & Tang, Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-10
- Volume
- 33
- Issue
- 10
- Pages
- 8365-8375
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2768415632
- Cited by
- 183
- References
- 2
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.