A Voltage-Based Open-Circuit Fault Detection and Isolation Approach for Modular Multilevel Converters With Model-Predictive Control
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Fault detection and isolation (FDI) is currently considered a crucial way to increase the reliability of modular multilevel converters (MMCs), which consist of a large number of power electronics submodules (SMs). This paper proposes a fast FDI approach to identifying single open-circuit faults of insulated-gate bipolar transistors in SMs for MMCs with model-predictive control (MPC). The fault detection approach is simply implemented by checking the voltage errors between the measured arm voltages and the estimated ones in the former control cycle. The fault isolation is achieved by checking the switching state directly. The proposed FDI scheme is straightforward, and no additional transducer or measurement is required. Compared with the phase-shifted pulse-width-modulation-based scheme, the MPC has a known and unchanged switching state in a sampling period, which can be utilized for fast location of open-circuit faults. Experimental results show that an open-circuit fault in the MMC can be accurately detected and located in several sampling periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346
Abu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039 · cited 1×
“, short-circuit faults and open-circuit faults [11].”
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623
Analysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
Model Predictive Control of High-Power Modular Multilevel Converters—An Overview
Dekka, A., Wu, B., Yaramasu, V., Fuentes, R. L., & Zargari, N. R. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2880137 · Cited by 231
Gou, B., Xu, Y., Xia, Y., Deng, Q., & Ge, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2994351 · Cited by 211
“Thus, the signal-based method is also popular in detecting the power semiconductor device fault and can be generally divided into current-based [23], [24] and voltage-based methods [25], [26].”
MethodXiao, Q., Jin, Y., Jia, H., Tang, Y. K., Cupertino, A. F., Mu, Y., Teodorescu, R., Blaabjerg, F., & Pou, J. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3283286 · Cited by 139
“In [37], when an SM is inserted or bypassed, additional sensors are applied to measure the arm voltages, and the numbers of their disorders are counted.”
BackgroundMethodSelf-citationYang, C., Gui, W., Chen, Z., Zhang, J., Peng, T., Yang, C., Karimi, H. R., & Ding, S. X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2924487 · Cited by 122
“The arm voltages are used to identify OC fault in the single-phase modular multilevel converters-based inverter [24].”
MethodSubmodule Voltage Similarity-Based Open-Circuit Fault Diagnosis for Modular Multilevel Converters
Zhou, D., Qiu, H., Yang, S., & Tang, Y. K. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2883989 · Cited by 122
“A fast and simple FDL scheme was proposed in [17] by taking advantage”
MethodSelf-citationA Transferrable Data-Driven Method for IGBT Open-Circuit Fault Diagnosis in Three-Phase Inverters
Xia, Y., & Xu, Y. H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3088889 · Cited by 131
“For those systems which are hardly modeled, signal-based methods [8]–[11] are widely applied by detecting characteristic distortion of sampled signals.”
BackgroundChai, M., Gorla, N. B. Y., & Panda, S. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978670 · Cited by 117
“been presented for modular multilevel converters [39] and matrix converters [40].”
BackgroundHang, J., Wu, H., Zhang, J., Ding, S., Huang, Y., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011450 · Cited by 118
Wen, H., Li, J., Shi, H., Hu, Y., & Yang, Y. B. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3045673 · Cited by 108
“The complexity of the algorithm implementation is important especially for software-based fault diagnosis methods, such as the harmonic-based method [35], [36], spectrum analysis method [37], sliding mode observer [38], Luenberger observer [39], and model predictive control [40].”
MethodZhou, D., Yang, S., & Tang, Y. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2863181 · Cited by 88
“Moreover, MMCs can operate even with faulty SMs through the utilization of fault-tolerant techniques, which improves the reliability of MMCs [11], [12].”
BackgroundSelf-citationGorla, N. B. Y., Kolluri, S., Chai, M., & Panda, S. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2918148 · Cited by 76
“and offshore oil rigs [4], [5], where the economic loss due to the downtime is significant.”
BackgroundA Diagnosis Strategy for Multiple IGBT Open-Circuit Faults of Modular Multilevel Converters
Chen, X., Liu, J., Deng, Z., Song, S., Du, S., & Wang, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2997963 · Cited by 67
Ali, M., Din, Z., Соломин, Е. В., Cheema, K. M., Milyani, A. H., & Che, Z. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.11.058 · Cited by 68
Open-Circuit Fault Diagnosis of Dual Active Bridge DC-DC Converter With Extended-Phase-Shift Control
Zheng, M., Wen, H., Shi, H., Hu, Y., Yang, Y. B., & Wang, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2899133 · Cited by 64
“In [38] and [39], model predictive control was adopted for the OCFs in modular multilevel converters.”
MethodZhao, F., Xiao, G., Zhu, T., Xu, Z., Wu, Z., & Zhao, T. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2913696 · Cited by 64
A Hybrid Model-Based Diagnosis Approach for Open-Switch Faults in PMSM Drives
Huang, W., Du, J., Hua, W., Bi, K., & Fan, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3123144 · Cited by 58
An Open-Circuit Faults Diagnosis Method for MMC Based on Extreme Gradient Boosting
Hu, X., Jia, H., Zhang, Y., & Deng, Y. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3194584 · Cited by 57
“…normallyrequirenoextrasensorsanddiagnosethefaultswhen realmeasuredvaluesdeviatefromcertainthresholds[2],which comparetheconsistencyofvoltagetolocatethefaultbyusing aslidingmodeobserver[4],[11],stateobserver[12],single ring theorem [13], Kalman filtering [14], and model predictive control[15],[16].”
BackgroundZhou, D., & Tang, Y. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2888879 · Cited by 56
Self-citationAhmed, H. M., Jlassi, I., Cardoso, A. J. M., & Bentaallah, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3132236 · Cited by 59
“In [14], the error between the measured and estimated voltages is used to detect the open-circuit fault for a modular multilevel converter, whereas the fault is identified by checking the switching states.”
MethodAviña-Corral, V., Rangel‐Magdaleno, J., Barrón-Zambrano, J. H., & Rosales-Nunez, S. A. (2024) · Measurement · doi:10.1016/j.measurement.2024.114864 · Cited by 64
Active Common-Mode Voltage-Based Open-Switch Fault Diagnosis of Inverters in IM-Drive Systems
Cheng, Y., Sun, Y., Li, X., Dan, H., Lin, J., & Su, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2965430 · Cited by 55
Wang, K., Lin, J. T., Li, G., Deng, Y., & He, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2959074 · Cited by 51
“2959074 predictive control based method [4], and single-ring-theorybased method [5].”
MethodA Concurrent Diagnosis Method of IGBT Open-Circuit Faults in Modular Multilevel Converters
Jia, H., Deng, Y., Hu, X., Deng, Z., & He, X. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3208647 · Cited by 53
“Existing studies on IGBT open-circuit fault can be mainly divided into three types: hardware-based [11], [12], [13], [14], [15], [16], data-based [17], [18], [19], [20], and model-based [10], [21], [22], [23], [24], [25], [26], [27].”
BackgroundZhou, D., Tu, P., Qiu, H., & Tang, Y. K. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2911959 · Cited by 44
“A voltage-based FDI method with model predictive control (MPC) was proposed in [12] to fast isolate the open-circuit fault.”
BackgroundMethodSelf-citationLiu, C., Deng, F., Cai, X., Wang, Z., Chen, Z., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122816 · Cited by 46
Fully Simulated Data-Driven Domain Generalized Method for Multiphase Converters Fault Diagnosis
Xu, H., Liu, Z., Wang, G., Jiang, D., & Sun, W. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3461159 · Cited by 45
“These methods diagnose the health of the system by identifying fault characteristic components within sampled signals, such as voltage signals [7] and current signals [8].”
Review of Fault Detection and Diagnosis Techniques for AC Motor Drives
Gultekin, M. A., & Bazzi, A. M. (2023) · Energies · doi:10.3390/en16155602 · Cited by 57
“For For multilevel inverters, model-predictive control is widely used and is also utilized as a fault-detection method as in [96,97]. multilevel inverters, model-predictive control is widely used and is also utilized as a fault-detection method as in [96,97].”
MethodOpen-Circuit Fault Detection in PMSM Drives Using Model Predictive Control and Cost Function Error
Huang, W., Luo, L., Du, J., Xiang, B., Mei, S., Zhou, L., & Fan, Q. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3135039 · Cited by 39
“A fast fault detection approach was proposed in [13] to identify a single OCF of IGBTs by accessing the errors between the measured arm voltages and the estimated”
MethodA Fast Diagnosis Scheme for Multiple Switch Faults in Cascaded H-Bridge Multilevel Converters
Xie, D., Lin, C., Deng, Q., Ge, X., & Gou, B. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3058989 · Cited by 39
“based methods are explored in some literature [18], [19].”
MethodAdaptive Fast Fault Location for Open-Switch Faults of Voltage Source Inverter
Yin, H., Chen, Y., Chen, Z., & Li, M. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3093643 · Cited by 37
Li, G., Xu, S., Sun, Z., Yao, C., Ren, G., & Ma, G. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3310491 · Cited by 36
Phase Loss Detection Using Voltage Signals and Motor Models: A Review
Dianov, A., & Anuchin, A. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3120887 · Cited by 34
Liu, Z., Xiao, L., Wang, Q., Li, J., & Wu, Q. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3096987 · Cited by 30
Serra, J., Jlassi, I., & Cardoso, A. J. M. (2021) · Machines · doi:10.3390/machines9120306 · Cited by 30
A Voltage-Based Multiple Fault Diagnosis Approach for Cascaded H-Bridge Multilevel Converters
Xie, D., Wang, H., Ge, X., Deng, Q., Gou, B., & Ma, L. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3108895 · Cited by 30
“Instead of102 using sensors, the measured arm voltages and the estimated103 ones are expressed by the circuit mathematical equations and104 the former control signals in the MPC [26], respectively.105 Considering the difference of the capacitor voltages before106 and after fault, the correlation coefficients between t…”
BackgroundInfluentialAn Online Metric Learning-Based Open-Switch and Current Sensor Fault Diagnosis for MSPMSM Systems
Du, Y., Li, C., & Zheng, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3265936 · Cited by 32
“Therefore, the fault diagnosis method through signal analysis is also very popular, which can be divided into the voltage-based method [13], [14] and the current-based method [15], [16].”
MethodWei, X., Wang, H., Luo, A., He, Z., Zhu, X., Sun, R., & Chen, X. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3028801 · Cited by 28
“However, this method was also time-consuming when the number of submodules was large [17].”
MethodWang, C., Zheng, Z., Wang, K., & Li, Y. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3150166 · Cited by 27
“Open-loop observers are utilized in [26]–[28] to estimate actual branch”
MethodLu, F., Guo, Q., Dou, Z., Chen, Y., Wang, Q., An, X., & Dou, H. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3550582 · Cited by 28
“When such faults occur, they can result in significant overcurrent within a very brief period, potentially damaging the device [6].”
Model predictive control and protection of MMC-based MTDC power systems
Shetgaonkar, A., Liu, L., Lekić, A., Popov, M., & Pálenský, P. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108710 · Cited by 29
Huang, Z., & Wang, Z. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2918166 · Cited by 24
Hu, K., Meng, X., Liu, Z., Xu, J., Lin, G., & Tong, L. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3161988 · Cited by 22
Current behavior-based open-switch fault on-line diagnosis of inverters in PMSM drive systems
Zhang, Y. (2022) · Measurement · doi:10.1016/j.measurement.2022.111810 · Cited by 24
Zhao, F., Xiao, G., Zhu, T., Zhao, T., Xu, Z., & Wu, Z. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914245 · Cited by 23
“THE modular multilevel converter (MMC) has been proved to be a popular and attractive choice in the medium- and high-power applications [1], [2], especially in the high-voltage direct current transmission system [3].”
BackgroundXia, Y., & Xu, Y. H. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3494858 · Cited by 24
Fault-Tolerant Operation of the DC/DC Modular Multilevel Converter Under Submodule Failure
Razani, R., & Mohamed, Y. A. I. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3050122 · Cited by 21
Liu, Z., Xiao, L., Cao, X. L., & Deng, Z. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3225583 · Cited by 22
“By Table II, the most popular method for switch fault diagnosis is the model-based FDL method [18], [19], [20], [21], [22], [23], [25], [26], [27], [28], [29], [30], [31], [32], [33], [34], because they do not require additional hardware and have relatively low computational costs.”
MethodInfluentialRonanki, D., & Williamson, S. S. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722277 · Cited by 21
“Researchers have made significant contributions to enhance the reliability of an MMC including redundancy of SMs [24], reliability modeling [25], fault diagnosis [16], [26], [27] and fault reconfiguration control schemes [16], [17], [27]–[29].”
BackgroundAn Integral Sliding Mode Observer Based Fault Diagnosis Approach for Modular Multilevel Converter
Faraz, G., Majid, A., Khan, B., Saleem, J., & Rehman, N. U. (2019) · International Conference on Electrical, Communication, and Computer Engineering (ICECCE) · doi:10.1109/icecce47252.2019.8940781 · Cited by 18
“Increasing the number of submodules means that the number of voltage-levels are increased, which is directly translated into lower harmonic content and enhances the capability to produce higher voltages [3]-[5].”
BackgroundTime-Domain Characterization and Detection of Open Circuit Faults for H-Bridge Power Cell
Kumar, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3103851 · Cited by 23
Ipoum‐Ngome, P. G., Flesch, R. C. C., Mon‐Nzongo, D. L., Tang, J., Jin, T., & Wang, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3127014 · Cited by 19
Song, C., Zhao, X., Sun, X., Diao, N., & Zhao, J. B. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3212398 · Cited by 18
“Although the traction motor can continue to operate, the large electromagnetic torque pulsation of the motor would cause secondary disasters and affect the overall reliability of the high-speed rail system [8], [9], [10].”
BackgroundA Fast Diagnosis Method for Power Switch Faults in Inverter Based on DC Voltage Waveform
Wang, Z., Ye, Z., Yang, G., Zhuo, B., & Chen, C. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3379977 · Cited by 18
“Broadly, the mainstream diagnostic techniques can be categorized into the data-driven methods [5], [6], [7], [8], [9], [10] and model-based methods [11], [12], [13], [14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26].”
BackgroundMethodZhang, Y., Hu, H., Liu, Z., Zhao, M., & Cheng, L. (2019) · Systems Science & Control Engineering · doi:10.1080/21642583.2019.1650840 · Cited by 18
“It should be noted that the results in FD of MMC so far have been mostly focused on the model-based research (Li, Shi, Wang, & Wang, 2015; Xu, Xie, Yuan, & Yan,2017; Zhou, Yang, & Tang, 2018).”
BackgroundCirculating Current-Based Open-Circuit Fault Diagnosis for Parallel Inverters
Fang, J., Li, M., Ding, S., & Hang, J. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3386805 · Cited by 18
Shi, S., Sun, Y., Li, X., Dan, H., & Su, M. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.2999692 · Cited by 15
“Reference [22] proposes a fast fault-detection and isolation approach to identify single open-circuit faults with model-predictive control.”
BackgroundComplementary Virtual Mirror Fault Diagnosis Method for Microgrid Inverter
Huang, Z., Wang, Z., & Song, C. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3053965 · Cited by 14
“[17] proposed a fault detection approach, which is simply implemented by checking the voltage errors between the measured arm voltages and the estimated ones in the former control cycle.”
BackgroundLiao, Y., & Zhang, Y. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3433030 · Cited by 13
“Compared to the state-of-the-art, Zhou et al. [7] carried out excellent robustness tests to consider the impact of uncertainties.”
BackgroundMethodInfluentialGorla, N. B. Y., & Panda, S. K. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9254851 · Cited by 14
“Similar method is proposed for the MMC and faults are detected without any additional sensors [20].”
BackgroundMethodInfluentialVoltage Signature Based Open Circuit Switch Fault Diagnosis Strategy for IM Drives With MPC
Manikandan, R., Selvaraj, R., & Singh, R. R. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3305340 · Cited by 12
“In [24], a fast fault detection approach was proposed to identify single OCFs in IGBT by comparing measured and estimated arm voltages from the previous control period.”
BackgroundMethodGeng, Z., Han, M., & Kou, L. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3144315 · Cited by 13
“That will influence the detection performance and increase the difficulty in selecting the thresholds for the methods in [19]–[22].”
BackgroundMethodCapacitance Estimation in Modular Multilevel Converters Under Nearest Level Modulation Scheme
Ronanki, D., & Williamson, S. S. (2019) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2019.8781087 · Cited by 12
“Recently, significant studies on MMC have been carried to enhance the reliability which is focused on redundancy submodule design [14], reliability based modeling [15], faulttolerant topologies [16] and fault-tolerant control methods [17]–[20].”
BackgroundZhang, Y., Li, S., Zhang, X., Liu, C., Liu, Z., & Luo, B. (2023) · IEEE Access · doi:10.1109/access.2023.3308950 · Cited by 11
“INTRODUCTION Modular Multilevel Converter (MMC) has attracted much attention due to its low harmonic distortion rate of the output voltage waveform, easy scalability and redundant design [1],”
BackgroundZhang, Y., Zhang, Y., Zhang, J., Deng, F., & Blaabjerg, F. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3344268 · Cited by 11
“To locate the faulty SMs within a short time, a number of methods have been proposed to better capture the voltage deviations, including the model-based methods [20], [21], [22], the statistics-based methods [23], [24], and the artificial intelligence-based methods [25], [26], [27].”
MethodA Reverse Model Predictive Control Strategy for a Modular Multilevel Converter
Guan, W., Huang, S., Luo, D., & Rong, F. (2019) · Energies · doi:10.3390/en12020297 · Cited by 10
Fu, Y., Meng, Z., Yang, X., & Ji, L. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3353782 · Cited by 11
“The FSC-MPC method was adopted by [14], [15], [24], [36], and the ML-based method was adopted by [37].”
MethodBenjamim, W., Jlassi, I., & Cardoso, A. J. M. (2022) · Electronics · doi:10.3390/electronics11030379 · Cited by 9
A Path-Based Switch Open Circuit Fault-Tolerant Method for Three-Phase DAB Converter
Guan, Y., Xiao, Y., Qin, L., Liu, X., Deng, H., & Wu, W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3316265 · Cited by 8
“However, for the SOCF in the single modular converter, the system will be interrupted, and the component overstress, transformer saturation, and transmission power loss will be exacerbated [9].”
BackgroundZhou, D., Tu, P., Qiu, H., & Tang, Y. K. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558371 · Cited by 8
“Several fault-tolerant control schemes have been developed for MMCs [16]–[20].”
BackgroundInfluentialSelf-citationSun, Y., Li, Z., & Zhang, Z. (2019) · IEEE Workshop on the Electronic Grid (eGRID) · doi:10.1109/egrid48402.2019.9092734 · Cited by 8
“In [6], the SM fault is detected by monitoring the errors between the measured and the estimated values of arm voltages, which utilizes the unchanged switching state of MPC algorithm in a sample interval.”
MethodXing, W., Xie, R., Yang, H., Chang, X., Sheng, J., Xiang, X. J., Li, W., & He, X. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487126 · Cited by 10
Xie, X., Li, H., Tan, H., Yao, R., & Zheng, J. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109127 · Cited by 9
Submodule power balancing control of modular multilevel converters under capacitor degradation
Ronanki, D., & Williamson, S. S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0261 · Cited by 10
Lei, X., Wu, F., & Liu, Y. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3669457 · Cited by 7
“Similar limitations are also observed across other rule-based methods, including those re-ported in [12], [13], [14], [15], [16], [17], [18], [19], [20], [21], [22], and [23].”
Yue, Y., Xu, Q., Guo, P., Chu, X., Shuai, Z., Luo, A., & Guerrero, J. M. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106729 · Cited by 7
Wu, F., Qiu, G., Zhang, L., Chen, K., Wang, L., Yu, J., & Gao, J. (2023) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.1077519 · Cited by 7
“For difficult-to-model systems, signal-based methods (Abari et al., 2017; Zhou et al., 2018a; Zhou et al., 2018b; Huang et al., 2021) (Abari et al., 2017; Zhou et al., 2018a; Zhou et al., 2018b; Huang et al., 2021) are widely used to detect the characteristic distortion of sampled signals.”
MethodFault Detection in Triple Star Bridge Cell Modular Multilevel Converter using Sliding Mode Observer
Caceres, S., Rojas, F., Barbosa, K. A., la Cuadra, T. D., Díaz, M., & Gatica, G. (2020) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit45562.2020.9067190 · Cited by 7
DC Voltage Control and OLTC Control Strategy for MMC-Based HVDC System Under SM Failure
Richa, A., Beig, A. R., & Jayashree, R. (2021) · IEEE Access · doi:10.1109/access.2021.3102377 · Cited by 8
“This paper focus is on FTO, so advanced works on fault detection can be found in [8]–[10], [30]–[33].”
BackgroundMethodInfluentialChaki, R., & Dey, A. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3544226 · Cited by 6
“The hardware based method provides easy to implement and quick identification of open circuit switch fault but at the expense of extra hardware circuitry in the form of FPGA and rectifier bridge [7] and additional arm voltage sensors [8], [9].”
Knowledge-data driven sampling diagnosis algorithm for lithium batteries on electric vehicles
Li, Q., Zhou, S., Zhou, X., Cui, H., Yifan, Z., Zhang, Z., Ma, T., Zhaolong, Z., Fei, C., Shichun, Y., et al. (2024) · ISA Transactions · doi:10.1016/j.isatra.2024.12.034 · Cited by 6
Yang, Q., & Saeedifard, M. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722083 · Cited by 6
Open-Circuit Fault Diagnosis and Tolerant Control for Modular Multilevel Converters
Wang, H., Wen, H., & Yang, R. (2020) · Chinese Automation Congress · doi:10.1109/cac51589.2020.9326905 · Cited by 6
Open Circuit Switch Fault Detection in Flying Capacitor and Cascaded H-Bridge Multilevel Converters
Hekmati, P., Brown, I., & Shen, Z. J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3078158 · Cited by 6
“A number of multilevel converter topologies have been developed and investigated, including diode clamped MCs, flying capacitor multilevel converters (FCMCs), modular multilevel converters (MMC), cascaded multilevel converters (CMC), and stacked Manuscript received October 21, 2020; revised January 29, 2021 and April…”
Faraz, G., Li, Z., Zhang, M., & Zhang, Z. (2021) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede51386.2021.9680958 · Cited by 6
Arsalan, A., Papari, B., Rahman, S. M. I., Timilsina, L., Moghassemi, A., Muriithi, G., Özkan, G., Edrington, C. S., & Buraimoh, E. (2024) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2024-01-2790 · Cited by 6
Liao, Y., Zhang, Y., You, J., Jin, L., Xu, Z., & Shen, Z. (2024) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2024.3406428 · Cited by 6
“[10], [11], [12], [13].”
BackgroundMethodInfluentialOpen-Circuit Fault Diagnosis and Tolerant Control of Matrix-Type Solid-State Transformer
Wang, H., Yu, T., Jiang, L. X., Chen, X., Zhang, G., & Su, M. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3390715 · Cited by 5
“OC failures may not initially cause damage [10], [11], but it can lead to overcurrent or overvoltage issues, and potentially trigger secondary faults.”
BackgroundHekmati, P., Brown, I. P., & Shen, Z. J. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721923 · Cited by 5
“In previous fault tolerant converters bypassing breakers or switches are needed for each commutation cell [6, 7, 9].”
BackgroundMethodInfluentialFault Detection in Parallel Devices of H-Bridge Inverters Using On-state Voltages and Load Current
Gultekin, M. A., Li, P., & Bazzi, A. M. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362918 · Cited by 5
Morel, C., Gueux, B. L., Rivero, S., & Chahba, S. (2023) · Actuators · doi:10.3390/act12060230 · Cited by 6
“The authors of [10] proposed a fast fault detection and isolation approach to identify a single open-circuit fault in power electronics sub-modules for modular multilevel converters with model-predictive control.”
BackgroundZhang, Y., Li, S. K., Luo, B., Luo, C., & Yu, Z. G. (2023) · IET Renewable Power Generation · doi:10.1049/rpg2.12843 · Cited by 4
Ahmadi, M., Shekhar, A., & Bauer, P. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3565768 · Cited by 4
Cheena, K. (2023) · Electric Power Components and Systems · doi:10.1080/15325008.2023.2180813 · Cited by 4
“The fault isolation has been realized by changing the switching states of the modular multilevel converter [19] without the transducer or sensor; the alternate fault in different areas is not covered.”
BackgroundArsalan, A., Papari, B., Timilsina, L., Muriithi, G., Moghassemi, A., Rahman, S. M. I., Buraimoh, E., Özkan, G., & Edrington, C. S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3546221 · Cited by 4
“Signal-based techniques can also be further divided into current-based [11], [12] and voltage-based [13], [14] methods based on the signal under test.”
Zhang, Y., Cheng, X., Liu, Z., Zheng, Y., & Cheng, C. (2020) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2020.12.172 · Cited by 5
Li, Y., Yang, Y., Lv, B., Tang, Q., & Ren, J. (2022) · International Conference on Electrical Engineering and Mechatronics Technology (ICEEMT) · doi:10.1109/iceemt56362.2022.9862724 · Cited by 4
“In [4-7] open-circuit faul can rapidly detect and locate, but can only locate individual IGBT open-circuit faults, which has certain limitations.”
BackgroundAn Overview of Power Conversion Systems in Contemporary Grid-Interactive Efficient Buildings (GEBs)
Saha, J., Siddique, M. D., Sundararajan, P., & Panda, S. K. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213729 · Cited by 4
Similarity-Based Fast Open-Circuit Fault Diagnosis Method for Modular Multilevel Converters
Zhou, D., Qiu, H., Yang, S., & Tang, Y. K. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797244 · Cited by 4
Self-citationHekmati, P., Shen, Z. J., & Brown, I. P. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912788 · Cited by 4
“This is typically accomplished by introducing breakers or switches in each commutation cell to route around the fault in a given cell [4, 5, 11].”
BackgroundInfluential
Metadata
- Authors
- Zhou, D., Yang, S., & Tang, Y.
- Affiliations
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-11
- Volume
- 33
- Issue
- 11
- Pages
- 9866-9874
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2790116484
- Cited by
- 143
- References
- 32
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 15 · 2023: 21 · 2022: 17 · 2021: 25 · 2020: 16 · 2019: 21 · 2018: 9
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Maritime Research Between Singapore (SMI) and Norway (SMI-2015-MA-15)
- Singapore Maritime Institute
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- fault detection and isolation, modular multilevel converter, model predictive control, open-circuit fault, IGBT, submodules, fault location, phase-shifted pulse width modulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.