A Voltage-Based Open-Circuit Fault Detection and Isolation Approach for Modular Multilevel Converters With Model-Predictive Control
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Fault detection and isolation (FDI) is currently considered a crucial way to increase the reliability of modular multilevel converters (MMCs), which consist of a large number of power electronics submodules (SMs). This paper proposes a fast FDI approach to identifying single open-circuit faults of insulated-gate bipolar transistors in SMs for MMCs with model-predictive control (MPC). The fault detection approach is simply implemented by checking the voltage errors between the measured arm voltages and the estimated ones in the former control cycle. The fault isolation is achieved by checking the switching state directly. The proposed FDI scheme is straightforward, and no additional transducer or measurement is required. Compared with the phase-shifted pulse-width-modulation-based scheme, the MPC has a known and unchanged switching state in a sampling period, which can be utilized for fast location of open-circuit faults. Experimental results show that an open-circuit fault in the MMC can be accurately detected and located in several sampling periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346
Abu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039 · cited 1×
“, short-circuit faults and open-circuit faults [11].”
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623
Analysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
Cited by
Items 101–143 of 143
Fault diagnosis of T-type three-level inverter based on bridge voltages
Chen, D., Liu, Y., & Zhang, S. (2021) · Archives of Electrical Engineering · doi:10.24425/aee.2021.136053 · Cited by 5
Adaptive Fault Detection for Grid-Forming Inverters
Intriago, G., & Zhang, Y. (2024) · IEEE Access · doi:10.1109/access.2024.3389073 · Cited by 4
“Signal processing based methods generally sample voltage, current, and auxiliary signals without an accurate system model [8], [9], [10], [11], [12].”
MethodDeep-Learning-based Fault Detection and Location Method Applied on Isolated Dc-Dc Converter
Gandomi, A. A., Kargar, M., Kargar, S., Parsa, L., & Corzine, K. A. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131570 · Cited by 4
A Deep Learning Network based Robust Fault Diagnosis Method for IGBT Open Circuit
Liu, Y., Sangwongwanich, A., Zhang, Y., Kong, R., Peng, Y., Hosani, K. H. A., & Wang, H. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567329 · Cited by 3
“When the health indicator exceeds the threshold, the fault is identified [9]–[11].”
BackgroundSimplified Model Predictive Control of Multilevel Converters With Internal Identical Structure
Zhou, D., Quan, Z., & Li, Y. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236064 · Cited by 2
“in multilevel converters due to its advanced merits, such as fast dynamic response, easy inclusion of nonlinear constraints [14]–[16].”
BackgroundSelf-citationModel Predictive Control of 5L-ANPC Converters with Level-Shifted Pulse-Width-Modulation
Zhou, D., Quan, Z., & Li, Y. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235951 · Cited by 3
“Multilevel converters have been extensively employed in industrial applications, such as grid-tied inverters [1], motor drive systems [2], energy storage system [3], and so on, thanks to their merits of better output voltage quality, reduced switching losses, high-reliability [4]–[8].”
BackgroundSelf-citationCheng, Y., Liu, C., Wu, H., Zhao, Y., & Wu, A. (2021) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede51386.2021.9680943 · Cited by 3
“For VSI and other converter systems based on model predictive control (MPC), the researches about open-switch fault diagnosis strategy are mostly concentrated on Matrix converter (MC) [16], multi-level inverter[17], [18], rectifier [19].”
MethodFault Detection and Identification in MMCs Based on DSCNNs
Cheng, G., & Song, S. (2023) · Energies · doi:10.3390/en16083427 · Cited by 3
Zhou, D., Yang, S., & Tang, Y. K. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8508029 · Cited by 3
“Fault diagnosis schemes for IGBT open-circuit faults of MMCs have been a hot-spot to improve the reliability of MMCs [10]–[16].”
BackgroundSelf-citationRobust Sensor Fault Reconstruction for Modular Multilevel Converter Based on Sliding Mode Observer
Cheng, X., Zhang, Y., & Liu, Z. (2019) · Chinese Automation Congress · doi:10.1109/cac48633.2019.8997237 · Cited by 4
“Currently, the main fault diagnosis methods of MMC are divided into methods including analysis model [8], [9], modern signal processing and artificial intelligence [10]–[12].”
MethodOpen Switch Fault Diagnosis of VSI-fed PMSM Drive using MPC Cost Function and Burg Algorithm
Manikandan, R., & Singh, R. R. (2022) · IEEE Industrial Electronics Society Annual On-Line Conference (ONCON) · doi:10.1109/oncon56984.2022.10126621 · Cited by 4
Model prediction-based switch open-circuit fault diagnosis and localization for MMCs
Liu, Z., & Xiao, L. (2025) · Journal of Power Electronics · doi:10.1007/s43236-025-01051-z · Cited by 2
“For example, in [35], counters were added and subtracted for bidirectional counting to quickly locate faults.”
Wensong, Z., Zheng, X., Zhang, D., & Lai, W. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/adead1 · Cited by 2
“According to the variations in the types of fault signals being processed, this method can be further classified into voltage-based [9– 11], current-based [12–14], and combined voltage and current-based [15, 16] methods.”
Ibarra, M. D. V., Vodanovic, G. T., Laprovitta, A. M., Peretti, G., Romero, E. A., & Anoardo, E. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae01c3 · Cited by 2
“This comparison is typically implemented by setting predefined thresholds for key parameters [17, 25, 26, 32], minimizing a diagnostic cost function [20], or through feature extraction and subsequent processing [19, 33].”
El-Naeem, K. S. A., Nayel, M. A.-A., Abdelrahem, M., & Alkabbany, I. M. (2025) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-025-10780-z · Cited by 6
“Model-based techniques are employed for detecting and isolating OCFs in power electronic converters, including pulse width modulation (PWM) voltage-source inverters [21, 22], interleaved converters [23], modular multilevel converters (MMCs) [24–26], and single-phase PWM rectifiers [27, 28].”
Review of fault detection, localization and tolerant in multilevel inverter
Phukan, H., Pati, A., Singh, J., & Bizon, N. (2026) · Energy Reports · doi:10.1016/j.egyr.2026.109038 · Cited by 3
Abari, I., Hamouda, M., Sleiman, M., Slama, J. B. H., Kanaan, H. Y., & Al‐Haddad, K. (2022) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem55808.2022.10044077 · Cited by 2
“Authors in [7] proposed a fault detection approach by evaluating the error between the estimated and the measured arm voltage.”
BackgroundHamayoon, S., Hovd, M., & Suul, J. A. (2023) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie51358.2023.10228064 · Cited by 2
“One of the main concerns for MMC is reliable operation as it consists of a large number of power semiconductor switches which are the most fragile components in power electronics systems [6].”
BackgroundMethodInfluentialSukanya, V., Bijukumar, B., Fahad, N. A., Mukundan, C. M. N., & Al‐Durra, A. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3561799 · Cited by 3
Open-Circuit Fault Detection Technique for Fault-Tolerant Bridgeless Boost Rectifier
Razak, R. K. A., Muhammad, K. S., Baharom, R., & Mamat, A. M. I. (2018) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i3.15.17523 · Cited by 2
“Besides, model predictive control method checking the voltage errors between the measured arm voltages and the estimated ones in the former control cycle [9].”
MethodHu, X., Zhang, D., Ni, P., Sun, K., & Zheng, X. (2025) · Electric Power Systems Research · doi:10.1016/j.epsr.2025.111916 · Cited by 2
Lei, X., Wu, F., & Liu, Y. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259759 · Cited by 1
Liu, Q., Xiao, L., Wu, Q., Wang, Q., & Niu, H. (2026) · Electric Power Systems Research · doi:10.1016/j.epsr.2026.112961 · Cited by 3
Zhou, D., Yang, S., & Tang, Y. K. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557902 · Cited by 2
“Moreover, MMCs can operate even with faulty SMs through the utilization of fault-tolerant techniques, which improves the reliability of MMCs [9], [10].”
BackgroundSelf-citationFast Open-Switch Fault Diagnosis Based on Model Reference Adaptive Theory Applied to Inverter System
Yin, H., Chen, Q., Guo, X., Qiu, X., Duan, X., & Zhao, X. (2022) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes56491.2022.10073066 · Cited by 1
“[15] Several switching periods Voltages High”
MethodClosed Loop Energy Balancing Control of Modular Multilevel Converters Under Capacitor Degradation
Ronanki, D., Kelkar, A., & Williamson, S. S. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927209 · Cited by 1
Wang, K., Lin, J. T., Li, G., Deng, Y., & He, X. (2019) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec45492.2019.8994401 · Cited by 1
“FDL method based on model predictive control proposed in [13] can also detect the SM failure with no additional transducer or measurement needed.”
MethodResearch on Turn-on Delay Time tdon of the Multichip IGBT Module after Partial Chip Failure
Han, A., Zhou, S., Fu, J., & Niu, Y. (2020) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei250167.2020.9346683 · Cited by 1
A Novel Diagnosis Method for IGBT Open-Circuit of Modular Railway Power Conditioner
Ding, H., Ma, F., Han, R. G., Xi, M., Zhang, C., & Xiong, X. (2022) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific56316.2022.9941901 · Cited by 1
“In [12], a fault diagnosis of SMs is realized by using model predictive control (MPC).”
MethodAbdellah, A., Larbi, M., & Toumi, D. (2023) · Electrical Engineering & Electromechanics · doi:10.20998/2074-272x.2023.6.06 · Cited by 2
Tan, H., Li, H., & Xie, X. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4106125 · Cited by 1
An Excitation Method for Fault Diagnosis of DC-AC Converter Based on Simulation
Yang, Y. H., Chen, C., Ye, X., & Sun, C. (2021) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc50364.2021.9459890
Current Predictive Control Strategy of T-Type Grid-Tied Inverter Based on Sliding Mode Observer
Wu, J., Fan, W., Dai, D., & Chen, M. (2022) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec54735.2022.9846213
2018 Index IEEE Transactions on Power Electronics Vol. 33
(2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3272449
Fault Detection and Identification for CHB-BESS Based on Convolutional Neural Network
Liu, Z., He, L., Ling, Z., & Li, X. (2023) · IEEE International Conference on Electrical Materials and Power Equipment (ICEMPE) · doi:10.1109/icempe57831.2023.10139593
“Tang present a voltage-based single-switch open-circuit fault FDI approach to enhance the reliability of MMCs with MPC [3].”
BackgroundFault Detection based on Perturbation Observer of Open-circuit Fault in Cascaded H-bridge STATCOM
Fan, C., Xiahou, K., & Wu, Q. (2023) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec58067.2023.10166337
Fast Fault Diagnosis of MMC: A Solution for Multiple Open-Circuit Faults
Zhao, W., Zhao, L., Yin, Y., Li, Z., Xie, X., & Zhang, Z. (2024) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec62217.2024.10892869 · Cited by 1
“However, the location speed of faulty SM with this strategy is slow and is influenced by the number of SMs. [11] improves on [10] to address multiple OC faults.”
An Octal-Switch Redundant Submodule for MMC to Tolerate Open-Circuit Faults
Wang, M., Lin, C.-H., Lee, P.-W., & Lee, T. (2024) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems60997.2024.10921090
Trust Evaluation Framework for Adaptive Load Optimization in Motor Drive System
Arsalan, A., Papari, B., Muriithi, G., Khan, A. A., Özkan, G., & Edrington, C. S. (2025) · Electronics · doi:10.3390/electronics14183697
Geng, Z., Yang, Y. B., Xiao, Y., Xie, W., Zhou, G., & Ni, K. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3635795
“However, the methods in [26] and [27] are incapable of handling the scenarios in which multiple types of faults occur in di ff erent arms in rectifier MMCs, which means that these methods cannot o ff er enough messages to shrink the localization scope under complex faults.”
InfluentialEl-Naeem, K. S. A., Nayel, M. A., Abdelrahem, M., & Alkabbany, I. M. (2026) · Scientific Reports · doi:10.1038/s41598-026-52101-w
Kumar, M. P., Velpula, S., & Saiprakash, C. (2026) · Transactions of the Institute of Measurement and Control · doi:10.1177/01423312261472646
Real-time detection and diagnosis of open-circuit power switch faults in parallel inverter systems
Ayoubi, M., Yessef, M., Chaibi, Y., & Chalh, Z. (2026) · Next Energy · doi:10.1016/j.nxener.2026.101138
Metadata
- Authors
- Zhou, D., Yang, S., & Tang, Y.
- Affiliations
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-11
- Volume
- 33
- Issue
- 11
- Pages
- 9866-9874
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2790116484
- Cited by
- 143
- References
- 32
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 15 · 2023: 21 · 2022: 17 · 2021: 25 · 2020: 16 · 2019: 21 · 2018: 9
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Maritime Research Between Singapore (SMI) and Norway (SMI-2015-MA-15)
- Singapore Maritime Institute
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- fault detection and isolation, modular multilevel converter, model predictive control, open-circuit fault, IGBT, submodules, fault location, phase-shifted pulse width modulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.