Cited by 155Advanced DC-DC ConvertersMultilevel Inverters and ConvertersHVDC Systems and Fault Protection

7.2-kV Single-Stage Solid-State Transformer Based on the Current-Fed Series Resonant Converter and 15-kV SiC mosfet s

Zhu, Qianlai, Wang, Li, Huang, Alex Q., Booth, Kristen, Zhang, Liqi·2019·IEEE Transactions on Power Electronics

Abstract

This paper proposes a novel two-level single-stage direct ac-ac converter for realizing a 7.2-kV medium-voltage (MV) solid-state transformer (SST) based on 15-kV SiC mosfets. A new current-fed series resonant converter (CFSRC) topology is proposed to address major challenges in MV ac-ac converters such as achieving zero-voltage switching (ZVS) for the MV mosfets across wide voltage and load ranges and minimizing system capacitance. The topology is analyzed with both time-domain analysis and first harmonic approximation to provide useful equations for circuit design. Constant deadtime strategy is adopted, allowing partial ZVS to occur at low-voltage (LV) levels. ZVS behavior over wide voltage range is investigated, and calculation of the associated loss from partial ZVS is presented. System parameters are optimized based on the tradeoff between conduction loss and switching loss. The 15-kV mosfet has been tested continuously at a park voltage of 10 kV and 37 kHz, indicating stable device operation and an extremely high voltage × frequency figure of merit. Moreover, inherent cycle-by-cycle current limiting in the proposed CFSRC under output short-circuit circumstance is realized by paralleling diodes to the LV resonant capacitors. Without employing any additional current sensors, the input and circulating currents are limited to a safe range automatically when the short-circuit occurs. This paper presents detailed short-circuit protection operating principles and peak resonant…

Integrity signals

Registry

Crossref · 10.1109/tpel.2018.2829174

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhu, Q., Wang, L., Huang, A. Q., Booth, K., & Zhang, L.
Affiliations
  • Apple (United States) (US)
  • Tesla (United States) (US)
  • The University of Texas at Austin (US)
  • North Carolina State University (US)
Venue
IEEE Transactions on Power Electronics
Published
2019-02
Volume
34
Issue
2
Pages
1099-1112
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2800026327
Cited by
155
References
4
Citations by year
2026: 9 · 2025: 15 · 2024: 13 · 2023: 30 · 2022: 28 · 2021: 22 · 2020: 19 · 2019: 11 · 2018: 8
FWCI
5.73
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Funders
National Science Foundation (EEC-0812121)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
Keywords
solid-state transformer, SiC MOSFET, zero-voltage switching, short-circuit protection, resonant tank design, high-voltage power conversion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review