The DOI matches its Crossref record; the references it cites are not checked yet.
Robust Stability Analysis of Synchronverters Operating in Parallel
Open accessAbstract
Recent studies have shown how synchronization units of converters operating nearby may interact with each other, affecting the stability of the system. Synchronverters are able to self-synchronize to the grid without the need of a dedicated unit because they can reproduce the power synchronization mechanism of synchronous machines. Recently, the robust stability of a synchronverter has been investigated by means of structured singular values (commonly called μ-analysis). In this paper, μanalysis is performed to investigate how the robust stability of a synchronverter is affected by the presence of another converter of the same type operating in parallel. It is demonstrated that the parallel operation of synchronverters reduces their robust stability and a possible solution is proposed, based on the implementation of virtual impedances in the control algorithm. An accurate state-space model of the system under study is developed by adopting the component connection method and the robust stability analysis is validated against time-domain simulations in MATLAB/Simulink/PLECS and experimental results with a power-hardware-in-the-loop test bench.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 34 · Cited by 117
Research works printed but not linked: 35
- 10.1109/TSG.2016.2594811 · DOI
- 10.1109/TPEL.2012.2186985 · DOI
- 10.1109/TPEL.2014.2382565 · DOI
- 10.1109/IECON.2018.8591758 · DOI
- lu, 2013, An islanding micro-grid power sharing approach using enhanced virtual impedance control, IEEE Trans Power Electron, 28, 5272, 10.1109/TPEL.2013.2243757 · DOI
- 10.1109/ECCE.2017.8095762 · DOI
- 10.1109/ECCE.2017.8096930 · DOI
- 10.1109/TIE.2016.2543181 · DOI
- 10.1109/TEC.2017.2771401 · DOI
- 10.1109/TPWRS.2015.2389822 · DOI
- 10.1109/TEC.2016.2645450 · DOI
- 10.1109/TPEL.2014.2306432 · DOI
- sun, 2009, Small-signal methods for ac distributed power systems—A review, IEEE Trans Power Electron, 24, 2545, 10.1109/TPEL.2009.2029859 · DOI
- amin, 0, Self-synchronization of wind farms in MMC-based HVDC system, Proc IEEE Elect Power Energy Conf, 1
- skogestad, 2001, Multivariable Feedback Control Analysis and Design
- zhou, 1998, Essentials of Robust Control
- 10.1109/TPEL.2012.2199334 · DOI
- 10.1109/TIA.2018.2800683 · DOI · Paper page
- 10.1109/TPEL.2013.2258684 · DOI · Paper page
- 10.1109/TSG.2018.2812712 · DOI
- 10.1109/TIE.2017.2674611 · DOI
- 10.1109/PESGM.2017.8274020 · DOI
- 10.1109/TPWRS.2009.2032231 · DOI
- 10.1109/TIE.2007.904022 · DOI
- 10.1109/TPEL.2015.2398192 · DOI
- 10.1109/TIE.2010.2048839 · DOI
- 10.1109/PSCC.2014.7038410 · DOI
- 10.1109/IECON.2017.8216078 · DOI
- 10.1109/TPEL.2018.2867040 · DOI · Paper page
- 10.1109/TIE.2017.2652387 · DOI
- 10.1109/IECON.2016.7793075 · DOI
- 10.1109/59.14550 · DOI
- 10.1109/ECCE.2018.8558426 · DOI
- 10.1109/TPEL.2013.2278716 · DOI
- kundur, 1994, Power System Stability and Control
Metadata
- Authors
- Rosso, R., Engelken, S., & Liserre, M.
- Affiliations
- Enercon (Germany) (DE)
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2019-11
- Volume
- 34
- Issue
- 11
- Pages
- 11309-11319
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2912532396
- Cited by
- 117
- References
- 34
- Citations by year
- 2026: 8 · 2025: 17 · 2024: 9 · 2023: 20 · 2022: 12 · 2021: 30 · 2020: 15 · 2019: 6
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- MACAU: Open Access Repository of Kiel University (University Library Kiel) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- synchronverter, robust stability, mu-analysis, structured singular value, parallel operation, virtual impedance, grid synchronization, distributed generation, state-space model, power hardware-in-the-loop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review