Transient Damping Method for Improving the Synchronization Stability of Virtual Synchronous Generators
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The virtual synchronous generator (VSG) was proposed to emulate a synchronous machine's dynamics when integrating power electronic converter-based distributed energy resources to the power grid. However, the VSG's synchronization stability during grid faults is not fully explored. The underlying mechanism of loss of synchronization still needs to be further revealed due to VSG's nonlinear characteristics. In this article, a step-by-step analytical method based on combining the linear and nonlinear models is proposed to analyze VSG's dynamic behaviors during a large disturbance. The relationship between the linear and nonlinear models is first brought to light, showing that the linear model is suitable for qualitative analysis to give an intuitive physical insight. Simultaneously, the latter is adopted for quantitative analysis to assess stability after a grid fault. Moreover, to avoid the conflict of the synchronization stability and the inertia response, a transient damping method is added in the active power control loop, which can simultaneously improve the synchronization stability and frequency stability. Design guidelines are also proposed to identify the parameter of the transient damping with different inertia requirements. Finally, the experimental results verify the analytical method and the theoretical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 1×
“This paradigm shift calls for grid forming control of the VSC, which means that the VSC should have the ability to support the frequency and voltage of the power grid [1].”
BackgroundSelf-citationSynchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 3×
“by an energy storage converter for integrating the renewable energy to the grid [10], [11], [20], [21].”
BackgroundMethodPower-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317 · cited 3×
“, an inductance Lg behind an infinite bus, is adopted [4], [5].”
BackgroundLi, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127 · cited 1×
“The reactive power-voltage (Q–V) droop control is employed [15], [28] for the reactive power control loop, and the transfer function of which is given by”
MethodInput-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117 · cited 1×
“An alternative one is the power synchronization control (PSC), which was proposed and analyzed in [4] and [5] to avoid the instability caused by the phase-locked loop in the gridfollowing control under a weak grid [6], [7].”
BackgroundGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039 · cited 1×
“Various control strategies have been proposed, among which the simplest and commonly used one is the P–f and Q–V droop control [2], [3].”
MethodSelf-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026 · cited 3×
“by an energy storage converter for integrating the renewable energy to the grid [10], [11], [20], [21].”
BackgroundMethodSmall-Signal Modeling and Parameters Design for Virtual Synchronous Generators
Wu, H., Ruan, X., Yang, D., Chen, X., Zhao, W., Lv, Z., & Zhong, Q. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543181 · Cited by 799 · cited 3×
“VSG's main parameters are presented in Table I, D p and K q are chosen according to the grid codes like in [5], [12].”
BackgroundMethodInfluentialZhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738 · cited 1×
“An alternative one is the power synchronization control (PSC), which was proposed and analyzed in [4] and [5] to avoid the instability caused by the phase-locked loop in the gridfollowing control under a weak grid [6], [7].”
BackgroundDong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709 · cited 1×
“been validated in previous research works [8], [15]–[18], [24], [25], thus, it will be further used without extra verification in this article.”
Method
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Chen, M., Zhou, D., & Blaabjerg, F. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3114723 · Cited by 236
“Several methods have been proposed to improve the largesignal angle stability of the VSG [21], [23]–[28].”
BackgroundMethodInfluentialSelf-citationWu, X., Wu, S., Wang, F., Wei, C., Li, R., Jiang, X., & Cai, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510361 · Cited by 24
Metadata
- Authors
- Xiong, X., Wu, C., Hu, B., Pan, D., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2021-07
- Volume
- 36
- Issue
- 7
- Pages
- 7820-7831
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3115441025
- Cited by
- 202
- References
- 28
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.