Abstract

This article presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This article analyzes the multiobjective, multidegree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulsewidth modulation, average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5-kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2021.3050115

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 28

Metadata

Authors
Zheng, L., Kandula, R. P., Kandasamy, K., & Divan, D.
Venue
IEEE Transactions on Power Electronics
Published
2021-08
Volume
36
Issue
8
Pages
8934-8952
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W3120994170
Cited by
28
References
4
FWCI
1.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance. https://app.cochat.ai/papers/10.1109/tpel.2021.3050115
The paper
Zheng, L., Kandula, R. P., Kandasamy, K., & Divan, D. (2021). Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2021.3050115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.