The DOI matches its Crossref record.
Development of Adaptive Protection Scheme for Distribution Systems With High Penetration of Distributed Generation
Abstract
Conventional power distribution system is radial in nature, characterized by a single source feeding a network of downstream feeders. Protection scheme for distribution system, primarily consisting of fuses and reclosers and, in some cases, relays, has traditionally been designed assuming the system to be radial. After connecting distributed generation (DG), part of the system may no longer be radial, which means the coordination might not hold. The effect of DG on coordination will depend on size, type, and placement of DG. This paper explores the effect of high DG penetration on protective device coordination and suggests an adaptive protection scheme as a solution to the problems identified. Results of implementation of this scheme on a simulated actual distribution feeder are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Majumder, R., Ghosh, A., Ledwich, G., & Zare, F. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2034666 · Cited by 332
Navigating the Complexities of Distributed Generation: Integration, Challenges, and Solutions
Saxena, V., Manna, S., Rajput, S. K., Kumar, P., Sharma, B., Alsharif, M. H., & Kim, M.-K. (2024) · Energy Reports · doi:10.1016/j.egyr.2024.09.017 · Cited by 82
Fault detection in Electrical Power Transmission System using Artificial Neural Network
Sahoo, B. K., Pradhan, S., Panigrahi, B. K., Biswal, B., Patel, N. C., & Das, S. (2020) · 2020 International Conference on Computational Intelligence for Smart Power System and Sustainable Energy (CISPSSE) · doi:10.1109/cispsse49931.2020.9212274 · Cited by 15
Metadata
- Authors
- Brahma, S. M., & Girgis, A. A.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2004-01
- Volume
- 19
- Issue
- 1
- Pages
- 56-63
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2177732305
- Cited by
- 679
- References
- 0
- FWCI
- 21.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of Adaptive Protection Scheme for Distribution Systems With High Penetration of Distributed Generation. https://app.cochat.ai/papers/10.1109/tpwrd.2003.820204
- The paper
- Brahma, S. M., & Girgis, A. A. (2004). Development of Adaptive Protection Scheme for Distribution Systems With High Penetration of Distributed Generation. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2003.820204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.