The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Micro-Grid Autonomous Operation During and Subsequent to Islanding Process
Abstract
This paper investigates (i) preplanned switching events and (ii) fault events that lead to islanding of a distribution subsystem and formation of a micro-grid. The micro-grid includes two distributed generation (DG) units. One unit is a conventional rotating synchronous machine and the other is interfaced through a power electronic converter. The interface converter of the latter unit is equipped with independent real and reactive power control to minimize islanding transients and maintain both angle stability and voltage quality within the micro-grid. The studies are performed based on a digital computer simulation approach using the PSCAD/EMTDC software package. The studies show that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the micro-grid and maintain voltage quality at designated buses, even during islanding transients. This paper concludes that presence of an electronically-interfaced DG unit makes the concept of micro-grid a technically viable option for further investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical power systems quality
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0322 · Cited by 2,608
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Vector analysis and control of advanced static VAR compensators
Schauder, C., & Mehta, H. (1993) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1993.0044 · Cited by 1,049
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“microgrid, whereas inverter output controllers should control and regulate the output voltages and currents [19], [20], [32], [54], [55].”
BackgroundDefining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Self-citationHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
Metadata
- Authors
- Katiraei, F., Iravani, M. R., & Lehn, P. W.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2005-01
- Volume
- 20
- Issue
- 1
- Pages
- 248-257
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2000920265
- Cited by
- 1,150
- References
- 4
- FWCI
- 40.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.