The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit
Abstract
This paper presents an active islanding detection method for a distributed resource (DR) unit which is coupled to a utility grid through a three-phase voltage-sourced converter (VSC). The method is based on injecting a negative-sequence current through the VSC controller and detecting and quantifying the corresponding negative-sequence voltage at the point of common coupling of the VSC by means of a unified three-phase signal processor (UTSP). UTSP is an enhanced phase-locked loop system which provides high degree of immunity to noise, and thus enable islanding detection based on injecting a small (3%) negative-sequence current. The negative-sequence current is injected by a negative-sequence controller which is adopted as the complementary of the conventional VSC current controller. Based on simulation studies in the PSCAD/EMTDC environment, performance of the islanding detection method under UL1741 anti-islanding test is evaluated, and its sensitivity to noise, grid short-circuit ratio, grid voltage imbalance, and deviations in the UL1741 test parameters are presented. The studies show that based on negative-sequence current injection of about 2% to 3%, islanding can be detected within 60 ms even for the worst case scenario.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haykin, S. (1986) · Cited by 12,603
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Micro-Grid Autonomous Operation During and Subsequent to Islanding Process
Katiraei, F., Iravani, M. R., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835051 · Cited by 1,150
Vector analysis and control of advanced static VAR compensators
Schauder, C., & Mehta, H. (1993) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1993.0044 · Cited by 1,049
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Nonlinear predictive control with application to manipulator with flexible forearm
Song, B. J., & Koivo, A. J. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793340 · Cited by 332
Ropp, M. E., Begovic, M. M., Rohatgi, A., Kern, G., Bonn, R., & Gonzalez, S. (2000) · IEEE Transactions on Energy Conversion · doi:10.1109/60.875495 · Cited by 310
Yazdani, A., & Iravani, R. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.874641 · Cited by 308
Self-citation
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Self-citationDistributed Control Techniques in Microgrids
Yazdanian, M., & Mehrizi-Sani, A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2337838 · Cited by 727
Review on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Self-citationPotential-Function Based Control of a Microgrid in Islanded and Grid-Connected Modes
Mehrizi-Sani, A., & Iravani, R. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2045773 · Cited by 428
Self-citationA survey on control issues in renewable energy integration and microgrid
Badal, F. R., Das, P., Sarker, S. K., & Das, S. K. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0122-8 · Cited by 357
Metadata
- Authors
- Karimi, H., Yazdani, A., & Iravani, R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-01
- Volume
- 23
- Issue
- 1
- Pages
- 298-307
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2167462156
- Cited by
- 377
- References
- 13
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit. https://app.cochat.ai/papers/10.1109/tpel.2007.911774
- The paper
- Karimi, H., Yazdani, A., & Iravani, R. (2008). Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2007.911774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.