Summary of Distributed Resources Impact on Power Delivery Systems

Walling, R.A., Saint, R., Dugan, R.C., Burke, J., Kojovic, L.A.·2008·IEEE Transactions on Power Delivery

Abstract

Because traditional electric power distribution systems have been designed assuming the primary substation is the sole source of power and short-circuit capacity, DR interconnection results in operating situations that do not occur in a conventional system. This paper discusses several system issues which may be encountered as DR penetrates into distribution systems. The voltage issues covered are the DR impact on system voltage, interaction of DR and capacitor operations, and interaction of DR and voltage regulator and LTC operations. Protection issues include fuse coordination, feeding faults after utility protection opens, impact of DR on interrupting rating of devices, faults on adjacent feeders, fault detection, ground source impacts, single phase interruption on three phase line, recloser coordination and conductor burndown. Loss of power grid is also discussed, including vulnerability and overvoltages due to islanding and coordination with reclosing. Also covered separately are system restoration and network issues.

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2007.909115

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Midday voltage rise, component overloading and voltage unbalance have been reported as major areas of concern as more PV systems are connected in distribution networks.

    “In the literature [20][21][22], midday voltage rise, component overloading and voltage unbalance have been reported as the major areas of concern as more PV systems are connected in distribution networks.”

Authors
Walling, R. A., Saint, R., Dugan, R. C., Burke, J., & Kojovic, L. A.
Affiliations
  • General Electric (United States) (US)
  • Electric Power Research Institute (US)
Venue
IEEE Transactions on Power Delivery
Published
2008-07
Volume
23
Issue
3
Pages
1636-1644
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2167315935
Cited by
1,024
References
0
Citations by year
2026: 12 · 2025: 20 · 2024: 36 · 2023: 48 · 2022: 50 · 2021: 77 · 2020: 69 · 2019: 72 · 2018: 98 · 2017: 96 · 2016: 100 · 2015: 74 · 2014: 63 · 2013: 46 · 2012: 65
FWCI
29.34
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Delivery (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
Keywords
distributed generation, electric power distribution systems, voltage regulation, capacitor bank, voltage regulator, load tap changers, fuse coordination, fault detection, ground faults, islanded operation, overvoltage, power grid vulnerability, system recovery, short-circuit capacity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review