The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Protection of Low-Voltage DC Microgrids
Abstract
In this paper, a low-voltage (LV) DC microgrid protection system design is proposed. The LV DC microgrid is used to interconnect distributed resources and sensitive electronic loads. When designing an LV DC microgrid protection system, knowledge from existing DC power systems can be used. However, in most cases, these systems use grid-connected rectifiers with current-limiting capability during DC faults. In contrast, an LV DC microgrid must be connected to an AC grid through converters with bidirectional power flow and, therefore, a different protection-system design is needed. In this paper, the operating principles and technical data of LV DC protection devices, both available and in the research stage, are presented. Furthermore, different fault-detection and grounding methods are discussed. The influence of the selected protection devices and grounding method on an LV DC microgrid is studied through simulations. The results show that it is possible to use available devices to protect such a system. Problems may arise with high-impedance ground faults which can be difficult to detect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Energy Storage and Its Use With Intermittent Renewable Energy
Barton, J. P., & Infield, D. G. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.822305 · Cited by 1,388
Micro-Grid Autonomous Operation During and Subsequent to Islanding Process
Katiraei, F., Iravani, M. R., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835051 · Cited by 1,150
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Low-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads
Salomonsson, D., & Sannino, A. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.883024 · Cited by 561
Self-citationOvercurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Baran, M. E., & Mahajan, N. R. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.877086 · Cited by 380
Meyer, J.-M., & Rufer, A. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.870981 · Cited by 380
Stored energy - Short-term and long-term energy storage methods
Kusko, A., & Dedad, J. (2007) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.4283511 · Cited by 78
Cited by
Smart Grid — The New and Improved Power Grid: A Survey
Fang, X., Misra, S., Xue, G., & Yang, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.101911.00087 · Cited by 3,405
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Metadata
- Authors
- Salomonsson, D., Soder, L., & Sannino, A.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2009-07
- Volume
- 24
- Issue
- 3
- Pages
- 1045-1053
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2158017035
- Cited by
- 712
- References
- 8
- FWCI
- 35.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.