The DOI matches its Crossref record.
A Control Strategy for Enhanced Operation of Inverter-Based Microgrids Under Transient Disturbances and Network Faults
Abstract
This paper proposes an enhanced control strategy for electronically coupled distributed energy resources that improves the performance of the host microgrid under network faults and transient disturbances. The proposed control strategy does not require controller mode switchings and enables the electronically coupled distributed energy resources to ride through network faults, irrespective of whether they take place within the host microgrid or impact the upstream grid. Moreover, the proposed control ensures acceptable power quality for the duration of the faults, which is an important feature for protection against certain classes of faults, as well as for sensitive loads. Further, the paper proposes a supplementary control loop that improves the microgrid post-fault recovery. The effectiveness of the proposed control strategy is demonstrated through a comprehensive set of simulation studies, conducted in the PSCAD/EMTDC software environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators
Paquette, A. D., & Divan, D. M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2345877 · Cited by 580
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“Based on how the saturated current reference ¯ 𝑖 𝑟𝑒 is calculated, three current limiters are commonly utilized for GFM inverters, including the instantaneous limiter [17], [27], [35], [36], the magnitude limiter [28], [37]–[40], and the priority-based limiter [15], [29], [41], [42].”
BackgroundMethodMicrogrid stability: Classification and a review
Shuai, Z., Sun, Y., Shen, Z. J., Tian, W., Tu, C., Li, Y., & Yin, X. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.201 · Cited by 368
Metadata
- Authors
- Zamani, M. A., Yazdani, A., & Sidhu, T. S.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2012-10
- Volume
- 27
- Issue
- 4
- Pages
- 1737-1747
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2042103507
- Cited by
- 161
- References
- 0
- FWCI
- 15.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Control Strategy for Enhanced Operation of Inverter-Based Microgrids Under Transient Disturbances and Network Faults. https://app.cochat.ai/papers/10.1109/tpwrd.2012.2205713
- The paper
- Zamani, M. A., Yazdani, A., & Sidhu, T. S. (2012). A Control Strategy for Enhanced Operation of Inverter-Based Microgrids Under Transient Disturbances and Network Faults. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2012.2205713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.